11
RS-232 Pin Assignment
Baud Rate: 57600 bps
Data Bit: 8-bit
Parity: None
Stop Bit: 1-bit
Flow Control: None
NOTE
: Use
Straight Through DB9 Cable
to connect the matrix with computer,
DO NOT
use
Crossover Cable (Null Modem Cable).
RS232 and Telnet Commands
No.
Command
Action
1
?
Print Help Information
2
HELP
Print Help Information
3
STATUS
Print System Status And Port Status
4
PON
Power On, System Run On Normal State
5
POFF
Power Off, System Run On Power Save State
6
IR ON/OFF
Set System IR Control On Or Off
7
KEY ON/OFF
Set System KEY Control On Or Off
8
BEEP ON/OFF
Set Onboard Beep On Or Off
9
LCD ON/OFF
Set LCD Always On Or Auto Turn Off In Power On State
10
RSB x
Set RS232 Baud Rate to X bps
x=[0:115200 1:57600, 2:38400, 3:19200, 4:9600]
11
RESET
Reset System To Default Setting
(Should Type "Yes" To Confirm, "No" To Discard)
12
RESET ALL
Reset System And Network To Default Setting
(Should Type "Yes" To Confirm, "No" To Discard)
16x16 Matrix
Remote Control Console
PIN
Assignment
PIN
Assignment
1
NC
1
NC
2
Tx
2
Rx
3
Rx
3
Tx
4
NC
4
NC
5
GND
5
GND
6
NC
6
NC
7
NC
7
NC
8
NC
8
NC
9
NC
9
NC