![Briggs & Stratton R020802 Operator'S Manual Download Page 6](http://html1.mh-extra.com/html/briggs-and-stratton/r020802/r020802_operators-manual_2811611006.webp)
6
2. Attach red end of high pressure hose (
A
) to high
pressure outlet (
B
) on pump. Tighten by hand.
3. Run water through your garden hose for 30 seconds
to clean out any debris.
NOTICE
DO NOT siphon standing water for the water
supply. Use ONLY cold water (less than 100°F (38°C)).
4. Before connecting garden hose (
C
) to water inlet (
D
),
inspect inlet screen (
E
). Clean screen if it contains
debris or have it replaced if damaged. DO NOT run
pressure washer if inlet screen is damaged.
NOTICE
Using a One Way Valve (vacuum breaker or
check valve) at pump inlet could cause pump or inlet
connector damage.
• There MUST be at least 10 ft. (3 m) of unrestricted
garden hose between the pressure washer inlet and any
device, such as a vacuum breaker or check valve.
• Damage to equipment resulting from failure to follow this
instruction will void warranty.
5. Connect the garden hose (
C
) (not to exceed 50 ft. (15
m) in length) to the water inlet (
D
). Tighten by hand.
Connect Spray Wand and 7-in-1 Nozzle
1. Turn ON the water, press red button (
F
) on the gun
and squeeze the trigger to purge the pump system of
air and impurities.
2. Place quick connect turbo (if equipped) and colored
spray tips in slots on holder attached to spray wand.
3. Attach spray wand to spray gun. Tighten by hand.
4. Choose spray tip you want to use, pull back on collar
of spray wand, insert spray tip and release collar. Tug
on spray tip to make sure it is securely in place. See
How to Use Spray Tips
.
Checklist Before Starting Pump Motor
Review the unit’s assembly to ensure you have performed
all of the following.
1. Be sure to read
Operator Safety
and
Operation
before
using the electric pressure washer.
2. Check for properly tightened hose connections.
3. Check to make sure there are no kinks, cuts, or
damage to hoses.
4. Provide a proper water supply at an adequate flow.
5. Plug electrical power cord into a dedicated electrical
circuit rated for 120 Volts AC at 15 Amps that is
properly installed in accordance with all local codes and
ordinances. Check that circuit is not used to supply any
other electrical needs.
WARNING
Risk of eye injury. Spray could splash
back or propel objects resulting in serious injury.
• Always wear indirect vented (chemical splash) safety
goggles marked to comply with ANSI Z87.1 when using
or in vicinity of this equipment.
• NEVER substitute safety glasses or dry-condition
goggles for indirect vented safety goggles.
F
B
A
D
E
C