background image

3

SAFETY RULES

5000W Portable Generator

PowerBOSS™

• When using generator for backup power, notify utility

company. Use approved transfer equipment to isolate
generator from electric utility.

• Use a ground circuit fault interrupter (GFCI) in any damp or

highly conductive area, such as metal decking or steel work.

• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are worn,

frayed, bare or otherwise damaged.

• DO NOT operate generator in the rain.
• DO NOT handle generator or electrical cords while standing

in water, while barefoot, or while hands or feet are wet.

• DO NOT allow unqualified persons or children to operate or

service generator.

Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.

WARNING

• This generator does not meet U. S. Coast Guard Regulation

33CFR-183 and should not be used on marine applications.

• Failure to use the appropriate U. S. Coast Guard approved

generator could result in bodily injury and/or property
damage.

WARNING

WHEN ADDING OR DRAINING FUEL
• Turn generator OFF and let it cool at least 2 minutes before

removing fuel cap. Loosen cap slowly to relieve pressure in
tank.

• Fill or drain fuel tank outdoors.

• DO NOT overfill tank. Allow space for fuel expansion.

• Keep fuel away from sparks, open flames, pilot lights, heat, and

other ignition sources.

• DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT
• Ensure spark plug, muffler, fuel cap and air cleaner are in place.

• DO NOT crank engine with spark plug removed.

• If fuel spills, wait until it evaporates before starting engine.

WHEN OPERATING EQUIPMENT
• Do not tip engine or equipment at angle which causes fuel to

spill.

• This generator is not for use in mobile equipment or marine

applications.

WHEN TRANSPORTING OR REPAIRING
EQUIPMENT
• Transport/repair with fuel tank EMPTY or with fuel shutoff

valve OFF.

• Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
• Store away from furnaces, stoves, water heaters, clothes

dryers or other appliances that have pilot light or other
ignition source because they can ignite fuel vapors.

Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.

WARNING

• Operate generator ONLY outdoors.

• Keep exhaust gas from entering a confined area through

windows, doors, ventilation intakes or other openings.

• DO NOT operate generator inside any building or enclosure,

including the generator compartment of a recreational vehicle (RV).

Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea,
fainting or death.

WARNING

• When starting engine, pull cord slowly until resistance is felt

and then pull rapidly to avoid kickback.

• NEVER start or stop engine with electrical devices plugged in

and turned on.

Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains could
result.

WARNING

Summary of Contents for PowerBoss 030222

Page 1: ...a Generador Helpline 1 800 743 4115 M F 8 5 CT web www briggsandstratton com PowerBOSS is a trademark of Briggs Stratton Power Products PowerBOSS es una marca registrada de Briggs Stratton Power Produ...

Page 2: ...ne owner s manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or...

Page 3: ...NOT light a cigarette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spills wait until it evaporat...

Page 4: ...tor if electrical output is lost equipment sparks smokes or emits flames unit vibrates excessively Improper treatment of generator can damage it and shorten its life CAUTION WHEN ADJUSTING OR MAKING R...

Page 5: ...ppliance tool and motor loads Air Cleaner Protects engine by filtering dust and debris out of intake air Choke Lever Used when starting a cold engine Circuit Breakers AC Each receptacle is provided wi...

Page 6: ...all contents against those listed below Main unit Engine oil Owner s manual Engine manual Wheel kit If any parts are missing or damaged call the generator helpline at 1 800 743 4115 INSTALL WHEEL KIT...

Page 7: ...r UNLEADED fuel with a minimum of 85 octane DO NOT use fuel which contains Methanol DO NOT mix oil with fuel 2 Clean area around fuel fill cap remove cap 3 Slowly add regular unleaded fuel to fuel tan...

Page 8: ...ce generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other op...

Page 9: ...3 Turn engine off according to instructions given in the engine owner s manual 4 Move fuel valve to Off position Fuel Valve is shown in the On position Figure 4 Fuel Valve See Don t Overload Generato...

Page 10: ...or greater 120 Volt AC 15 Amp Duplex Receptacle Each of these outlets is protected against overload by a push to reset circuit breaker Figure 6 Use each outlet to operate 120 Volt 60 Hz single phase...

Page 11: ...e generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each...

Page 12: ...garden hose to clean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cr...

Page 13: ...nt gum from forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the c...

Page 14: ...runs good at no load but bogs down when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t O...

Page 15: ...ctric powered pressure washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT I...

Page 16: ...ncia de Protecci n Ambiental Para mayor informaci n acerca de la garant a consulte con el manual del propietario del motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta de seguridad Sirve para adver...

Page 17: ...NTO EL EQUIPO Compruebe que la buj a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj a instalada Si se ha derramado combustible...

Page 18: ...los del generador Apague el generador si Se pierde la salida el ctrica El equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva El tratamiento inadecuado del generador pued...

Page 19: ...motor con aceite aqu Tanque del Combustible El tanque tiene una capacidad de 5 galones americanos de gasolina sin contenido de plomo Tomacorriente Dobles de 120 Voltios AC 15 Amp Pueden ser utilizados...

Page 20: ...tenido compar ndolo con la lista a continuaci n Unidad Principal Aceite del Motor Manual del Propietario Manual del Motor Juego de Ruedas Si cualquier parte falta o est da ada llame a la L nea de Ayud...

Page 21: ...de 85 octanos NO utilice combustible que contenga metanol ni mezcle aceite con combustible 2 Limpie el rea alrededor de la tapa de llenado del combustible retire la tapa 3 Agregue lentamente combusti...

Page 22: ...io que pueda estar ocupado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse F...

Page 23: ...el propietario del motor 4 Cierre la v lvula del combustible Vea No sobrecargue generador Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas Conecte las ca...

Page 24: ...en contra de sobrecargas por un corto circuitos de del tipo empuje para reposicionar Use cada recept culo para operar 120 Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 1 800 vatio...

Page 25: ...mente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional q...

Page 26: ...damos el uso de mangueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s...

Page 27: ...i comienza a oxidarse El xido y o la suciedad en la gasolina le causar problemas Almacene la unidad en un rea limpia y seca NO coloque una cubierta encima de un generador caliente Deje que la unidad s...

Page 28: ...VICIO DE BRIGGS STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT...

Reviews: