![Briggs & Stratton MS-1055 Repair Manual Download Page 92](http://html1.mh-extra.com/html/briggs-and-stratton/ms-1055/ms-1055_repair-manual_2810999092.webp)
11
23
STARTER SYSTEM
5. Remove two nuts with 14 mm wrench, Fig. 64.
6. Remove
components in sequence shown, Fig. 65.
Field Wire Terminal Side:
(1) G
(2) F
(3) E
(4) D
(5) C
(6) B
(7) A
Fig. 64 – Loosen Nuts
Battery Wire Terminal Side:
Before 99010100: 1.0 KW
/
After 98123100: 1.0 KW
Before 98083100: 1.2 KW
/
After 98090100: 1.2 KW
(1) N
(1) N
(2) M
(2) M
(3) L
(3) P
(4) K
(4) O
(5) J
(5) K
(6) I
(6) J
(7) H
(7) I
(8) H
7. Install components in sequence shown, Fig. 65.
Field Wire Terminal Side:
(1) A
(2) B
(3) C
(4) D
(5) E
(6) F
(7) G
Battery Wire Terminal Side:
Before 99010100: 1.0 KW
/
After 98123100: 1.0 KW
Before 98083100: 1.2 KW
/
After 98090100: 1.2 KW
(1) H
(1) H
(2) I
(2) I
(3) J
(3) J
(4) K
(4) K
(5) L
(5) O
(6) M
(6) P
(7) N
(7) M
(8) N
8. Do not tighten terminal nuts at this time.
Fig. 65 – Contact Assemblies
BEFORE 99010100: 1.0 KW
/
BEFORE 98083100: 1.2 KW
AFTER 98123100: 1.0 KW
/
AFTER 98090100: 1.2 KW
A
B
C
D
E
F
G
H
I
J
K
L
M
N
(1.2 KW)
(1.0 KW)
A
B
C
D
E
F
G
H
I
J
O
P
M
N
(1.2 KW)
(1.0 KW)
K