Briggs & Stratton Liquid-Cooled Home Generator System Operator'S Manual Download Page 20

20 

BRIGGSandSTRATTON.COM

The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time stated above. 
“Consumer use” means personal residential household use by a retail consumer. “Commercial use” means all other uses, including use for commercial 
or other income producing purposes. “Rental use” means any use of this product in a temporary or semi-permanently installed rental application. Once 
equipment has experienced commercial or rental use, it shall thereafter be considered as commercial or rental use for purposes of this warranty.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE 
RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING 
DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.

ABOUT YOUR WARRANTY

We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty 
repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if 
equipment damage occurred because of misuse, lack of routine maintenance, and shipping, handling, warehousing or improper installation. Similarly, the 
warranty is void if the manufacturing date or serial number(s) on the equipment has been removed or the equipment has been altered or modified. During the 
warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use 
and service. This warranty will not cover the following repairs and equipment:
• 

Normal Wear

: Outdoor Power Equipment and engines, like all mechanical devices, needs periodic parts and service to perform well. This warranty 

does not cover repair when normal use has exhausted the life of a part or the equipment.

• 

Installation and Maintenance

: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or 

alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as, in our judgment, 
to adversely affect its performance and reliability. 

• 

Exclusions

: For further clarification of engine warranty policies and procedures, contact Power Solutions Incorporated at 1-630-350-9400 or visit www.

PSIengines.com. IMPCO Technologies is the holder of the Manufacturer of Record of all Environmental Protection Agency (EPA) compliance issues 
related to the use and performance of the engine.

 

This warranty excludes wear items such as engine oil, oil gauges, o-rings, filters, fuses, spark plugs, or anti-freeze, starting batteries, etc., or damage 
or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing or freezing or chemical deterioration. Accessory parts 
are excluded from the product warranty. This warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers 
control. Also excluded is used, reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment 
used in life support applications.  

Warranty terms continue on next page.

Effective January 1, 2008 replaces all undated Warranties and all Warranties dated before January 1, 2008

LIMITED WARRANTY

Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material or 
workmanship or both. Travel expenses will be reimbursed as specified under the Briggs and Stratton Warranty Guidelines document to authorized 
Briggs & Stratton dealers for performing warranty repair work. This warranty is effective for the time periods and subject to the conditions stated below. 
For all warranty service, find the nearest Authorized Service Dealer in our dealer locator map at BRIGGSandSTRATTON.COM.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW.  ANY AND ALL IMPLIED WARRANTIES ARE 
EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some 
states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation 
of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and 
you may also have other rights which vary from state to state or country to country.

BRIGGS & STRATTON HOME POWER PRODUCTS GROUP, LLC 

STANDBY GENERATOR OWNER WARRANTY POLICY

4 years or 2000 hours, whichever comes first
2 years or 1000 hours, whichever comes first. First year 100% full 

coverage; second year alternator and engine only

None

Consumer Use
Commercial Use 

Rental Use

WARRANTY PERIOD

Summary of Contents for Liquid-Cooled Home Generator System

Page 1: ...Operator s Manual Liquid Cooled Home Generator System Manual No 205051GS Rev A 01 18 2008...

Page 2: ...ined by NFPA 70 NEC This home generator requires professional installation before use Refer to the separate Installation Manual for full information Follow the instructions completely Save these instr...

Page 3: ...el Factors 7 Generator Location 8 Essential Circuits 8 Delivery Inspection 9 Features and Controls 10 Operation 13 Automatic Operation 13 Setting Exercise Timer 14 Maintenance 14 Fault Detection Syste...

Page 4: ...teries give off explosive hydrogen gas during recharging Slightest spark will ignite hydrogen and cause explosion Battery electrolyte fluid contains acid and is extremely caustic Contact with battery...

Page 5: ...EGATIVE NEG or first When finished reconnect that cable last After your home generator is installed the generator may crank and start without warning any time there is a power failure To prevent possi...

Page 6: ...o it See Essential Circuits Start generator and let engine stabilize before connecting electrical loads notice Improper treatment of generator can damage it and shorten its life Use generator only for...

Page 7: ...e generator A thorough understanding of these options will provide fundamental control over the cost of your installation as well as ensure your final satisfaction and security Federal and local codes...

Page 8: ...epending on the power consumed by these circuits most or all of them can be switched to the home generator for the duration of normal power interruption The wattage reference table that follows will a...

Page 9: ...erage load factor of 80 of the standby rating The standby rating is only applicable for optional standby power where the generator set serves as the backup to the normal utility source Use the wattage...

Page 10: ...nd air cleaner E Oil Dip Stick Used to check the engine oil level F Oil Fill Cap Remove to service the engine with recommended oil G Engine Label Identifies engine model and type H Coolant Recovery Bo...

Page 11: ...s If the fuse has blown melted open or was removed the engine cannot crank or start Replace the fuse using only an identical ATO 15A fuse E System Switch This two position switch is the most important...

Page 12: ...hose panels should remain closed at all other times Each home generator is equipped with two identical keys These keys fit the locks that secure the access doors To Open an Access Door 1 Insert key in...

Page 13: ...fuse is properly installed upon completion of the installation Automatic Operation To select automatic operation do the following 1 Confirm 15 Amp fuse is installed in control panel 2 Set the main dis...

Page 14: ...Exercise procedure at the exact weekday and time you want it to take place Maintenance Servicing the System To service the home generator system 1 Remove 15 Amp fuse from control panel 2 Set control...

Page 15: ...lt is indicated by fault code FC_3 and three blinks on the LED indicator This condition is caused by a restriction in the fuel flow a broken or disconnected signal lead a failed alternator winding the...

Page 16: ...hen dust dirt oil moisture or other foreign substances are visible on its exterior interior surface NOTE DO NOT use direct spray from a garden hose to clean generator Water can enter the engine and ge...

Page 17: ...ng It may take up to 72 hours to fully charge a discharged battery with the trickle charge The trickle charge is not able to recharge a battery that is completely discharged 5 Connect negative battery...

Page 18: ...e label See the engine operator s manual for location of this information Please note that several different home generator systems are described in this manual so your unit s appearance may vary from...

Page 19: ...rvice facility 4 See Gaseous Fuel System in the Installation Manual 5 Remove kink Replace if necessary Engine will not start or starts and runs rough 1 15 Amp fuse missing or blown 2 Fuel supply turne...

Page 20: ...er Solutions Incorporated at 1 630 350 9400 or visit www PSIengines com IMPCO Technologies is the holder of the Manufacturer of Record of all Environmental Protection Agency EPA compliance issues rela...

Page 21: ...or nuclear holocaust 6 Any incidental consequential or indirect damages caused by defects in materials or workmanship or any delay in repair of replacement of the defective part s 7 Failure due to mi...

Page 22: ...0 kW Rated Maximum Load Current at 120 Volts 250 Amps at 240 Volts 125 Amps Rated AC Voltage 120 240 Volts Phase Single phase Rated Frequency 60 Hertz Normal Operating Range 20 F 28 8 C to 104 F 40 C...

Page 23: ...Manual del Operario Sistema generador dom stico enfriado por l quido...

Page 24: ...ones relativas a la seguridad de los procedimientos de instalaci n El instalador deber seguir las instrucciones al pie de la letra Guarde estas instrucciones para futuras consultas D nde encontrarnos...

Page 25: ...mbustible 7 Ubicaci n del Generador 8 Circuitos Fundamentales 8 Inspecci n al Momento de la Entrega 10 Controles y caracter sticas 11 Operaci n 14 Funcionamiento Autom tico 14 Configuraci n del Tempor...

Page 26: ...n siendo recargadas Una peque a chispa puede encender el hidr geno y causar una explosi n El fluido de electrolito de la bater a contiene cido y es extremadamente c ustico El contacto con el fluido d...

Page 27: ...generador de dom stico est instalado el generador puede arrancar manualmente sin ninguna advertencia cada vez que se produce una falla en el suministro de electricidad Para evitar posibles lesiones si...

Page 28: ...de da arlo y acortar su vida productiva Use el generador solamente con la finalidad para el cual fue dise ado Si usted tiene alguna pregunta acerca de las finalidades de uso del generador preg ntele a...

Page 29: ...o del Generador Dom stico la informaci n necesaria para lograr la instalaci n m s rentable y satisfactoria posible Las ilustraciones se aplican a circunstancias t picas y est n destinadas a que usted...

Page 30: ...n los que los gases de escape se puedan acumular o entrar en un edificio que pueda estar ocupado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n...

Page 31: ...tiempo Este total NO debe ser mayor que la capacidad de vatiaje del generador La potencia nominal de la iluminaci n puede obtenerse observando las lamparillas La potencia nominal de las herramientas...

Page 32: ...entrega se detecta alguna p rdida o da o solicite a la persona o personas encargadas de la entrega que dejen debida constancia en la nota de entrega y que firmen debajo de la nota del consignador don...

Page 33: ...Medir el Aceite Se utiliza para controlar el nivel de aceite del motor F Tapa del Compartimiento de Aceite Se debe retirar para llenar la unidad con el aceite recomendado G Etiqueta del Motor Identif...

Page 34: ...e ha retirado el motor no se puede arrancar ni arrancar manualmente en forma lenta Cambie el fusible por otro id ntico ATO de 15 A E Conmutador del Sistema Este dispositivo de dos posiciones es el con...

Page 35: ...dor y al radiador que se utilizan para limpiar dichos componentes Dichos paneles deben permanecer cerrados el resto del tiempo Cada generador de reserva dom stico est equipado con dos llaves id nticas...

Page 36: ...el panel de distribuci n principal que alimenta tensi n de la red al conectador en la posici n ON 3 Sit e el interruptor principal del generador en la posici n ON 4 Ponga el conmutador del sistema del...

Page 37: ...nfiguraci n de pr ctica Set Exercise exactamente el d a de la semana y a la hora en que desea que se lleve a cabo Mantenimiento Paro del Sistema Para brindar servicio al sistema generador dom stico 1...

Page 38: ...n FC_3 Este fallo se indica mediante el c digo de fallo FC_3 y tres parpadeo del LED Esta situaci n puede ser debida a una restricci n del caudal de combustible un cable de se ales roto o desconectad...

Page 39: ...onsiste en conservar la unidad limpia y seca Opere y almacene la unidad en un ambiente limpio y seco donde no ser expuesta al polvo suciedad humedad o vapores corrosivos Las ranuras del aire de enfria...

Page 40: ...Las bater as almacenadas producen hidr geno explosivo mientras est n siendo recargadas Una peque a chispa puede encender el hidr geno y causar una explosi n El fluido de electrolito de la bater a cont...

Page 41: ...iduos sueltos Puede usar aire a baja presi n que no exceda los 25 psi para eliminar la suciedad Inspeccione las ranuras para aire de enfriamiento y la apertura del generador Estas aperturas deber n ma...

Page 42: ...ci n El sistema de combustible gaseoso del Manual de instalaci n 5 Consulte la secci n El sistema de combustible gaseoso del Manual de instalaci n El motor no arranca o arranca pero funciona con dific...

Page 43: ...enamiento o la instalaci n inadecuados De manera similar la garant a quedar anulada si se ha borrado la fecha de fabricaci n o el n mero de serie del equipo o si el equipo ha sido alterado o modificad...

Page 44: ...ina el transporte la manipulaci n el almacenamiento o la instalaci n inadecuados De manera similar la garant a quedar anulada si se ha borrado la fecha de fabricaci n o los n meros de serie del equipo...

Page 45: ...rivados o indirectos causados por defectos en los materiales o en la mano de obra o por cualquier retraso en la reparaci n o la sustituci n de los componentes defectuosos 7 Fallos debidos a la mala ap...

Page 46: ...orriente de Carga Nominal M xima a 120 Voltios 250 Amperios a 240 Voltios 125 Amperios Tensi n de c a Nominal 120 240 Voltios Fases Monof sico Frecuencia Nominal 60 Hz Rango Operativo Normal 28 8 C 20...

Page 47: ...Manuel de l Utilisation Groupe lectrog ne refroidissement par liquide...

Page 48: ...on professionnelle avant l utilisation Consultez le manuel d installation s par pour les directives sur les proc dures s curitaires d installation Votre installateur devrait suivre les instructions d...

Page 49: ...opri taire 7 Facteurs Relatifs au Combustible 7 Emplacement de la G n ratrice 8 Circuits Essentiels 8 V rification de la Livraison 10 Fonctions et commandes 11 Fonctionnement 14 Fonctionnement automat...

Page 50: ...qu elles se rechargent La plus petite tincelle enflammera l hydrog ne et provoquera une explosion Le liquide d lectrolyte de l accumulateur contient de l acide et est extr mement caustique Le contact...

Page 51: ...e panne lectrique Pour pr venir des blessures potentielles AVANT de travailler sur l quipement r glez toujours l interrupteur de syst me sur OFF ET enlevez le fusible de 15 Amp res avertissement Le ga...

Page 52: ...s utilisations pr vues Si vous avez des questions concernant les utilisations pr vues demandez votre distributeur ou contactez Briggs Stratton Ne faites fonctionner le g n rateur que sur des surfaces...

Page 53: ...section pr sente au propri taire du groupe lectrog ne les renseignements dont il aura besoin pour que l installation du groupe lectrog ne soit la plus satisfaisante et conomique possible Les illustra...

Page 54: ...xt rieur N installez PAS la g n ratrice dans un endroit o les gaz d chappement pourraient s accumuler et p n trer ou tre aspir s dans un difice qui pourrait tre occup Assurez vous que les gaz d chappe...

Page 55: ...mpes est indiqu e sur les ampoules La puissance nominale des outils lectriques des appareils lectrom nagers et des moteurs est habituellement indiqu e sur les plaques ou les d calques appos s sur les...

Page 56: ...ns l espace r serv cet effet Apr s la livraison si vous remarquez des pi ces manquantes ou des dommages mettez les pi ces endommag es de c t et communiquez avec le transporteur pour conna tre les proc...

Page 57: ...et au filtre air E Jauge d Huile Utilis e pour v rifier le niveau d huile du moteur F Bouchon de remplissage d huile Enlevez le pour effectuer l entretien du moteur avec le type d huile recommand G P...

Page 58: ...s circuits de commande C C du groupe lectrog ne Si le fusible est grill fondu et ouvert ou a t enlev le moteur ne peut tre lanc ou d marrer Remplacez le fusible grill uniquement par un fusible ATO ide...

Page 59: ...ateur permettant le nettoyage de ces pi ces Ces panneaux doivent demeurer ferm s tout autre moment Chaque groupe lectrog ne r sidentiel est muni de deux cl s identiques Ces cl s s adaptent aux serrure...

Page 60: ...t charg e l installation Si la tension de la batterie est inf rieure 12 volts rechargez celle ci Consultez la rubrique Batterie de la section Entretien pour de plus amples d tails REMARQUE N utilisez...

Page 61: ...h l unit ex cutera imm diatement un cycle d exercice puis fera de m me tous les dimanches 10 h heure REMARQUE Le r glage du cycle d exercice ne fonctionnera que si l unit est en mode AUTO et que si la...

Page 62: ...lisant des contacts normalement ferm s qui sont maintenus ouverts par la pression de l huile du moteur lorsque celui ci est en marche Si la pression d huile baisse sous les 8 lb po2 les manocontacts s...

Page 63: ...er l aide de l installateur ou de votre centre de service local Entretien du G n rateur La garantie de la g n ratrice ne couvre pas les l ments soumis l abus ou la n gligence de l op rateur Pour obten...

Page 64: ...dre jusqu 72 heures pour se recharger compl tement Le chargeur faible d bit ne peut tre utilis pour recharger une batterie compl tement plat 5 l aide de la quincaillerie fournie branchez le fil noir d...

Page 65: ...emplissez le r servoir de gaz propane 2 Comptez le nombre de clignotements et r f rez vous Syst me de D tection des Pannes Perte de puissance sur les circuits essentiels 1 Disjoncteur ouvert sur la g...

Page 66: ...ABRICATION DU PRODUIT COMME DATE DE R F RENCE POUR D TERMINER LA P RIODE DE GARANTIE PROPOS DE LA GARANTIE Nous acceptons de faire effectuer les r parations couvertes par la garantie et tenons nous ex...

Page 67: ...pas pr sente 3 Toutes les applications d appareils de location 4 Toute perte de revenus d coulant directement ou indirectement de la d faillance de cet appareil 5 Les d faillances dues une cause exter...

Page 68: ...W Charge Nominale Maximum 120 Volts 250 Amp res 240 Volts 125 Amp res Tension Nominale C A 120 240 Volts Phase Monophas Fr quence Nominale 60 Hz Plage d Utilisation Normale 28 8 C 20 F to 40 C 104 F N...

Reviews: