Assembly Instructions
Technical Specifications
SPECIFICATIONS
COMPONENT
22,000 RPM
1/4 in. (6.35 mm)
4.5 CFM/0.3 m³/min
90 PSI/6.3 bar
1/4 in. (6.35 mm) NPT (F)
3/8 in. (9.53 mm) (inner diameter)
Free speed
Collet size
Avg. air consumption
Working pressure
Air inlet
Air hose
3. Mount a leader hose (not included) by hand into the air
inlet (C). (See Figure 3)
1. Remove the air inlet protective cap from the air inlet (C).
(See Figure 1)
C
Figure 1
NOTE
Use thread sealant tape (not included) on the male
plug and tighten it with a wrench for airtight connection.
Do not overtighten.
C
Figure 3
Figure 4
4. Loosen the collet jacket (F) counterclockwise by hand or
with the large wrench (H) while holding the small wrench (I)
on the flats of the collet holder (E). (See Figure 4)
Figure 5
5. Insert the grinding accessory into the collet (G).
(See Figure 5)
F
E
H
G
Figure 6
6. Tighten the collet jacket (F) clockwise with large wrench (H)
while holding the small wrench (I) on the flats of the collet
holder (E). Make sure that the grinding stone is installed
securely and tightly. (See Figure 6)
7. Connect air supply hose to the leader hose.
I
F
E
H
I
WARNING
Only use grinding accessories that have
an RPM rating equal to or greater than the tool itself.
8. Set the working pressure at 90 PSI/6.3 bar for best tool
performance.
5
2. Place 2-3 drops of air tool oil (not included) into the male
plug before each use. (See Figure 2)
Figure 2
Not
for