DON'T OVERLOAD

GENERATOR

Capacity

You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1.

Select the items you will power at the same time.

2.

Total the rated (running) watts of these items. This is
the amount of power your generator must produce to
keep your items running. See Figure 12.

3.

Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.

Example:

Total Rated (Running) Watts

= 1875

Highest Additional Surge Watts

= 1600

Total Generator Output Required = 3475

Power Management

To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator. There should be nothing connected to the
generator outlets before starting it's engine. The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1.

With nothing connected to the generator, start the
engine as described in this manual.

2.

Plug in and turn on the first load, preferably the largest
load you have.

3.

Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.

4.

Plug in and turn on the next load.

5.

Again, permit the generator to stabilize.

6.

Repeat steps 4 and 5 for each additional load.

NEVER add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity,
as described above.

*Wattages listed are approximate only. Check tool or
appliance for actual wattage.

Tool or Appliance

Rated (Running)
Watts

Additional Surge
(Starting) Watts

Refrigerator

800

1600

Deep Freezer

500

500

Television

500

-

Light (75 Watts)

75

-

1875 Total Running
Watts

1600 Highest Surge
Watts

Tool or Appliance 

Rated* 

(Running) 

Watts 

Additional 

Surge 

(Starting) 

Watts 

Essentials 

 

 

Light Bulb - 75 watt 

75 

Deep Freezer 

500 

500 

Sump Pump 

800 

1200 

Refrigerator/Freezer - 18 Cu. Ft. 

800 

1600 

Water Well Pump - 1/3 HP 

1000 

2000 

Heating/Cooling 

 

 

Window Fan 

300 

600 

Furnace Fan Blower - 1/2 HP 

800 

1300 

Kitchen 

 

 

Microwave Oven - 1000 Watt 

1000 

Coffee Maker 

1500 

Electric Stove - Single Element 

1500 

Hot Plate 

2500 

Family Room 

 

 

Stereo Receiver 

450 

Television - 27” 

500 

Personal Computer w/17” monitor 

800 

Other 

 

 

AM/FM Clock Radio 

300 

Electric Water Heater - 40 Gallon 

4000 

Quartz Halogen Work Light 

1000 

Airless Sprayer - 1/3 HP 

600 

1200 

Reciprocating Saw 

960 

960 

Electric Drill - 1/2 HP 

1000 

1000 

Circular Saw - 7 1/4” 

1500 

1500 

Miter Saw - 10” 

1800 

1800 

Table Saw/Radial Arm Saw - 10” 

2000 

2000 

Air Compressor - 1-1/2 HP 

2500 

2500 

Figure 12 - Wattage Reference Chart

Summary of Contents for 30239

Page 1: ...lez Ligne d assistance de G n rateur Llame L nea Directa del Generador 1 800 743 4115 M F 8 5 CT web www briggsandstratton com Before using this product read this manual and follow all Safety Rules an...

Page 2: ...TY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety aler...

Page 3: ...odily injury and or property damage WARNING WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fi...

Page 4: ...R MAKING REPAIRS TO YOUR GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester...

Page 5: ...ssistance Engine ON OFF Switch Used to stop a running engine Fuel Shut Off Valve Use this valve to turn the fuel supply on and off Fuel Tank Capacity of 1 32 U S gallons 5 0 liters of fuel Grounding L...

Page 6: ...gned to greatly improve the portability of your generator it is not intended for over the road use You will need a needle nose pliers to install this kit Refer to Figure 1 and install the wheel kit as...

Page 7: ...2 Clean area around fuel fill cap remove cap 3 Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion as shown in Figure 3 NOTE Occa...

Page 8: ...e generator in a well ventilated area which will allow for removal of deadly exhaust gas DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occup...

Page 9: ...e and servicing In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lan...

Page 10: ...tem shuts down the engine add engine oil Charging a Battery Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery DO NOT use the unit to char...

Page 11: ...arge a battery EXTENSION CORDS Use only high quality well insulated extension cords with the generator s 120 Volt electrical receptacles Check the ratings of all extension cords before you use them Su...

Page 12: ...nt icing problem 10 Start and run engine outdoors 11 Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings 12 DO NOT enclose generator any more tha...

Page 13: ...in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next...

Page 14: ...power This difference is due to a variety of factors including but not limited to the following differences in altitude temperature barometric pressure humidity fuel engine lubrication maximum govern...

Page 15: ...iness of the generator frequently and clean when dust dirt oil moisture or other foreign substances are visible on its exterior surface NOTE DO NOT use a garden hose to clean generator Water can enter...

Page 16: ...d tighten securely 8 Wipe up any spilled oil 9 Reconnect spark plug wire to spark plug KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Clean Replac...

Page 17: ...ver screws Clean Spark Arrester Screen The engine muffler is equipped with a removable spark arrester screen Inspect and clean the screen every 10 hours of operation or every 3 months whichever comes...

Page 18: ...slowly to distribute oil Generator 1 Clean generator as outlined in Generator Cleaning 2 Check that cooling air slots and openings on generator are open and unobstructed Other Storage Tips 1 DO NOT st...

Page 19: ...t of gasoline 5 Stale gasoline 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in gasoline 9 Flooded 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Eng...

Page 20: ...2000W Generator 20 NOTES...

Page 21: ...2000W Generator 21 NOTES...

Page 22: ...s you should contact a Briggs and Stratton Power Products Service Representative at 1 800 743 4115 The emission warranty is a defects warranty Defects are judged on normal engine performance The warra...

Page 23: ...ctric powered pressure washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT I...