background image

2

SAFETY RULES

TABLE OF CONTENTS

Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-16
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 & 22
Emissions Control Warranties . . . . . . . . . . . . . . . . . . . 20-21
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-44

EQUIPMENT

DESCRIPTION

Read this manual carefully and become
familiar with your generator. Know its
applications, its limitations and any hazards
involved.

The generators are an engine–driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances, tools and motor loads.The generator’s
revolving field is driven at about 3,600 rpm by a single-
cylinder engine.

CAUTION!

DO NOT exceed the generator’s

wattage/amperage capacity. See “Don’t Overload
Generator”.

Every effort has been made to ensure that information in
this manual is accurate and current. However, we reserve
the right to change, alter or otherwise improve the product
and this document at any time without prior notice.

The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency and the California Air Resources Board.

SAFETY RULES

This is the safety alert symbol. It is used to
alert you to potential personal injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.

The safety alert symbol (

) is used with a signal word

(DANGER, CAUTION,WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER indicates
a hazard which, if not avoided, will result in death or serious
injury. WARNING indicates a hazard which, if not avoided,
could result in death or serious injury. CAUTION
indicates a hazard which, if not avoided, might result in
minor or moderate injury. CAUTION, when used
without the alert symbol, indicates a situation that could
result in equipment damage. Follow safety messages to
avoid or reduce the risk of injury or death.

Hazard Symbols and Meanings

The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.

WARNING

Copyright © 2006 Briggs & Stratton Power Products
Group, LLC. All rights reserved. No part of this material
may be reproduced or transmitted in any form by any
means without the express written permission of Briggs &
Stratton Power Products Group, LLC.

SAVE THESE INSTRUCTIONS

Fire

Explosion

Toxic Fumes

Hot Surface

Electrical Shock

Kickback

Operator’s Manual

Flying Objects

Summary of Contents for 30219

Page 1: ...4115 M F 8 5 CT web www briggsandstratton com BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Manual No 199824GS Revision A 04 25 2006 5000 WATT 6250 STARTING WATTS Before using thi...

Page 2: ...fornia Air Resources Board SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible...

Page 3: ...orless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death WARNING WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel...

Page 4: ...ent sparks smokes or emits flames unit vibrates excessively Improper treatment of generator can damage it and shorten its life CAUTION WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR Disconnect the...

Page 5: ...cal overload Data Tag Provides model revision and serial number of generator Please have these readily available when calling for assistance Fuel Tank Capacity of four 4 U S gallons 15 l Fuel Valve Us...

Page 6: ...h with a 13mm socket Pliers Safety glasses Refer to Figure 1 and install the wheel kit as follows 1 Tip generator so that engine end is up 2 Slide axle through both mounting brackets 3 Place a wheel o...

Page 7: ...an area around fuel fill cap remove cap 3 Slowly add unleaded gasoline to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion as shown in Figure 2 4 Install fuel cap...

Page 8: ...in a confined area Figure 3 Prevailing winds and air currents should be taken into consideration when positioning generator When using generator for backup power notify utility company Use approved t...

Page 9: ...5 ft 152 cm clearance on all sides of generator including overhead Code of Federal Regulation CFR Title 36 Parks Forests and Public Property require equipment powered by an internal combustion engine...

Page 10: ...SET The generator comes with a 25 generator adapter cord set designed to provide two sets of 120Volt 20 Amp outlets from one 120Volt 20 Amp duplex receptacle Figure 8 The generator adapter cord set p...

Page 11: ...to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load N...

Page 12: ...aximum governed engine speed individual engine to engine variability design of the particular piece of power equipment the manner in which the engine is operated engine run in to reduce friction and c...

Page 13: ...ry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged...

Page 14: ...inter use and works best in cold conditions Checking Oil Level Oil level should be checked prior to each use or at least every 5 hours of operation Keep oil level maintained 1 Make sure generator is o...

Page 15: ...oil fill opening to the point of overflowing at oil fill DO NOT overfill 7 Reinstall oil fill cap Finger tighten cap securely 8 Wipe up any spilled oil Clean Replace Spark Plug Change the spark plug...

Page 16: ...authorized service dealer Muffler Spark Arrester Screen Heat Shield DO NOT touch hot surfaces and avoid hot exhaust gases Allow equipment to cool before touching Keep at least 5 ft 152 cm clearance o...

Page 17: ...ll warm drain oil from crankcase Refill with recommended grade Oil Cylinder Bore Remove spark plug and pour about 1 2 ounce 15 ml of clean engine oil into the cylinder Install spark plug and pull reco...

Page 18: ...to Off 2 Fuel Valve is in Off position 3 Dirty air cleaner 4 Out of fuel 5 Stale fuel 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in fuel 9 Flooded 10 Excessively rich fuel...

Page 19: ...NOTES 19 NOTES...

Page 20: ...to an in use emissions test Briggs Stratton Emissions Control Defects Warranty Provisions The following are specific provisions relative to your Emissions Control Defects Warranty Coverage It is in a...

Page 21: ...efore the Emissions Durability Period of an engine with an intermediate rating would equate to 10 to 12 years The Air Index is a calculated number describing the relative level of emissions for a spec...

Page 22: ...NOTES 22 NOTES...

Page 23: ...ty repair and apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty servi...

Page 24: ...izado para juegos est ndares por la Agencia de Protecci n Ambiental y el Consejo de recursos de aire de California REGLAS DE SEGURIDAD ste es el s mbolo de alerta de seguridad Sirve para advertir al u...

Page 25: ...garrillo o fume CUANDO PONGA EN FUNCIONAMIENTO EL EQUIPO Compruebe que la buj a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj...

Page 26: ...produce chispas humo o emite llamas La unidad vibra de una manera excesiva El tratamiento inadecuado del generador puede da arlo y acortar su vida productiva PRECAUCI N CUANDO AJUSTE O HAGA REPARACION...

Page 27: ...tos Proporciona el modelo revisi n y el n mero de serie de generador Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda Interruptor Balanc n Deber estar en la posici n On En para...

Page 28: ...te la Figura 15 e instale el juego de ruedas conforme a las instrucciones siguientes 1 Dele la vuelta al generador de forma que el motor quede arriba 2 Introduzca el eje a trav s de los dos soportes d...

Page 29: ...p sito para permitir la expansi n del combustible como se muestra en la Figura 16 4 Instale la tapa del tanque de combustible y la espera para alg n combustible rociado para evaporar Para evitar probl...

Page 30: ...erador Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica Use un in...

Page 31: ...e el motor cuando haya aparatos el ctricos conectados y en funcionamiento El r pido repliegue del cable del arrancador retroceso impedir que el usuario suelte el cable a tiempo y tirar de su mano y br...

Page 32: ...e 25 pies dise ado para un circuito neutro a tierra de 120 voltios 20 Amperios Figura 22 El juego de cables del adaptador del generador provee un suministro conveniente de energ a para cualquier emerg...

Page 33: ...onectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA...

Page 34: ...mec nico utilizado manera de hacer funcionar el motor rodaje del motor para reducir la fricci n y limpiar las c maras de combusti n ajustes de las v lvulas y el carburador etc Los valores de potencia...

Page 35: ...en el circuito de combustible del motor y provocar p rdidas de rendimiento o fallos Asimismo si penetran l quidos en el generador a trav s de las ranuras del aire de refrigeraci n parte del l quido pu...

Page 36: ...Comprobaci n del Nivel de Aceite Compruebe el nivel de aceite antes de cada uso o cada 5 horas de funcionamiento como m nimo Rellene si es necesario 1 Coloque el generador sobre una superficie nivela...

Page 37: ...ite 6 Vierta lentamente unos 0 6 litros 20 onzas de aceite por el orificio de llenado hasta el punto de desbordamiento NO a ada aceite en exceso 7 Vuelva a colocar el tap n de llenado de aceite Apri t...

Page 38: ...rvicio Figura 27 Servicio al Pantalla Apagachispas Limpieza Figura 28 Sistema de Refrigeraci n de Aire NO cambie ninguna velocidad determinada El generador suministra una frecuencia y un voltaje calif...

Page 39: ...o Aceite el Di metro Interior del Cilindro Quite la buj a y vierta aproximadamente 15 ml 1 2 onza de aceite de motor limpio en el interior del cilindro Coloque la buj a y arranque lentamente para dist...

Page 40: ...aire sucio 4 Sin gasolina 5 Gasolina vieja 6 El cable de la buj a no est en malas la buj a 7 Buj a defectuosa 8 Agua en la gasolina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La v l...

Page 41: ...41 NOTAS NOTAS...

Page 42: ...os Los defectos se juzgan en funci n del rendimiento normal del motor La garant a no depender de ninguna prueba de emisiones en funcionamiento Disposiciones de la garant a contra defectos del sistema...

Page 43: ...n motor con clasificaci n intermedia equivaldr a a 10 12 a os El ndice de aire es un valor calculado que indica el nivel relativo de emisiones de una gama concreta de motores Cuanto menor es el ndice...

Page 44: ...tarios destinados al mantenimiento de las constantes vitales Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante...

Reviews: