A. ELECTRIC MOTOR:

AIR COMPRESSOR PUMP:

B. AIR TANK:

The tank is used to store the compressed air.

C. TANK PRESSURE GAUGE:

D. AIR PRESSURE REGULATOR:

WARNING

Never exceed the maximum working pressure of the tool.

E. REGULATED PRESSURE GAUGE:

The gauge is used to measure the regulated outlet pressure. 

F. AIR LINE OUTLET: 

The outlet is used to connect air hose with quick connector.

G. AIR TANK BALL VALVE:

The ball valve is used to remove moisture from the air tank after the unit is 

shut off. 

WARNING

Never attempt to open the drain valve when the tank pressure is more than 10 PSI. 

8

                                 The motor is used to power the pump. It contains a thermal overload protector. If 

the motor overheats for any reason, the thermal overload protector will shut it down in order to prevent 

the motor from being damaged. 

                                           The pump is used to compress the air and discharge it into the tank via the 

piston moving up and down in the cylinder.

                                          The gauge is used to measure the stored air pressure level of the tank. It is

not adjustable by the operator and does not indicate line pressure.  
                                               The regulator is used to adjust line pressure to the tool you are using. 

Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure.

H. PRESSURE RELIEF VALVE:

I. ON/OFF SWITCH:

J. POWER CORD:

DANGER

Grounded 

outlet 

Grounding Pin 

Plug 

Figure 1 

                                            The valve is used to prevent system the system. If the pressure reaches the 

preset leve motor, it will automatically pop open. You can also pull the ring on the valve to open. 
                             This switch turns on the compressor and is operated manually. When in the ON 

position, it allows the operated manually. When in the ON demand. ALWAYS set this switch to OFF 

when the compressor is not being used and before unplugging the compressor. 
                          This product is for use on a nominal 120-volt circuit and should be grounded. A cord

with a grounding plug as illustrated must be used. Make sure that the product is connected to an outlet 

that has the same configuration as the plug (see Figure 1). No adapter should be used with this 

Check with a licensed electrician if the grounding instructions are not 

understood or there is doubt as to whether the product is properly 

grounded. Do not modify the plug provided. If it will not fit the outlet, 

have the proper outlet installed by a licensed electrician.

Improper installation of the grounding plug will result in a risk 

of electric shock. If repair or replacement of the cord or plug is 

necessary, do not connect the grounding wire to either flat 

blade 

terminal. The grounding wire is in the green outer surface.

Parts Description

Not 

for 

Reproduction

Summary of Contents for 074025-00

Page 1: ...product It contains important information for your safety as well as operating and maintenance advice BRIGGS STRATTONCORPORATION MILWAUKEE WISCONSIN U S A 8 GAL PORTABLE OIL FREE AIR COMPRESSOR Produ...

Page 2: ...brand When operated and maintained according to the instructions in this manual your Briggs Stratton air compressor will provide many years of dependable service You can contact Briggs Stratton Custom...

Page 3: ...code below from your mobile device Product updates Helpful maintenance and usage tips Discounts and offers on future products product online Whether you absolutely love your new product or have a sug...

Page 4: ...aintenance Troubleshooting Exploded View Parts List Warranty Key Parts Diagram 4 SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and foll...

Page 5: ...or unsafe Warning Bursting Hearing Fire The safety alert symbol indicates a potential hazard to personal injury A signal word DANGER WARNING or CAUTION is used with the alert symbol to designate a deg...

Page 6: ...k of re could result in death or serious injury Do not operate with pressure switch or safety valve set above maximum allowable working pressure Hot compressor surfaces could result in serious injury...

Page 7: ...Pressure Relief Valve F Air Line Outlet G Air Tank Ball Valve D Air Pressure Regulator I ON OFF Switch B Air Tank A Electric Motor Air Compressor Pump L Wheel K Handle J Power Cord M Air Filter C Tank...

Page 8: ...decrease pressure H PRESSURERELIEFVALVE I ON OFFSWITCH J POWERCORD DANGER Grounded outlet Grounding Pin Plug Figure 1 The valve is used to prevent system the system If the pressure reaches the preset...

Page 9: ...leeve Fasten the handle to the sleeve using the screws AA 1 M6 14 Screw x 2 AA HardwareUsed 2 Wheel assembly Insert the bolt BB through one of the wheels L slide on washer CC Insert the bolt BB throug...

Page 10: ...hat may cause eye injury Wear safety glasses when opening the drain valve WARNING To avoid personal injury always shut off and unplug the unit and relieve all air pressure from the system before perfo...

Page 11: ...the tank hoses pipe connections or transfer tubes will reduce the unit s performance Spray a small amount of soapy water around the area of the suspected leak with a spray bottle If bubbles appear re...

Page 12: ...RNING 6 Immediately replace the tank DO NOT attempt to repair 7 Replace the compressor assembly 8 Replace the compressor assembly 9 Replace the compressor assembly Air leaks from the regulator or the...

Page 13: ...wn fuse or reset the circuit breaker Do not use a fuse or circuit breaker with a higher rating than speci ed for your branch circuit Check for proper fuse type T fuse is acceptable Check for low volta...

Page 14: ...RIGGSandSTRATTON COM BRIGGS STRATTON is a trademark of BRIGGS STRATTON CORPORATION and is used under license to Alton Industry Co Ltd Alton Industry Co Ltd warrants this Briggs Stratton brand product...

Page 15: ...T 16 AWG 72 in Length NOTE Avoiduseofextensioncords Ifuseofanextensioncordcannotbeavoided thecordshouldbeaminimum wiresizeof12AWGandnolongerthan30feet Useonlya3 wireextensioncordthathasa3 bladegroundi...

Page 16: ...BRIGGSandSTRATTON COM 16 ExplodedView N o t f o r R e p r o d u c t i o n...

Page 17: ...re gauge Front shroud Switch retainer On Off switch Run capacitor 50 f Start capacitor 200 f Eblow Pump Motor assembly Fan 2 2 1 1 2 1 1 1 1 1 2 1 1 1 1 1 1 1 1 Air lter Back shroud Bolt M8 X 25 Tranf...

Reviews: