Step 2: Oil and Fuel

  1. Move generator outdoors to a flat, level surface.
  2.  Turn dial and open cover over oil fill area.

  3.  Clean area around oil fill, remove oil fill cap/dipstick and 

wipe with clean cloth. Replace dipstick. Remove and 

check oil level.

NOTICE   

Do not screw in dipstick when checking oil level.

  4.  Verify oil is at full mark on dipstick. Replace and 

tighten oil fill cap/dipstick.

  5.  If needed, see 

Maintenance

 for instructions to add oil.

  6.  Replace cover over oil fill area.

Low Oil Indicator   

The low oil indicator system is designed to prevent engine 

damage caused by not enough engine oil. If engine oil level 

drops below a preset level, the red LED low oil indicator light 

comes on and an oil level switch will stop the engine. If engine 

stops or the red LED low oil indicator light comes on when 

you try to start the generator, check the engine oil level.

Fuel must meet these requirements:
  •  Clean, fresh, unleaded fuel with a minimum of 91 RON 

(87 octane/87 AKI).

  •  Gasoline with an ethanol content up to 10% is acceptable.

E10

   

E15

NOTICE  

 Do not mix oil in fuel or modify engine to run on 

alternate fuels. Use of unapproved fuels could damage 

engine and will not be covered under warranty.
See 

High Altitude

 for 1524 m and above.

WARNING!

   Fuel and its vapors are extremely 

flammable which could cause burns or fire  

resulting in death or serious injury.

•  Do not refuel during operation.

•  Do not smoke during refueling.

•  Turn engine off and let it cool at least 2 minutes before 

removing fuel cap.

•  Fill fuel tank outdoors. Keep fuel away from sparks, open 

flames, pilot lights, heat, and other ignition sources. 

Check fuel lines, tank, cap and fittings frequently for 

cracks or leaks. Replace if necessary.

  7.  Slowly remove fuel cap to relieve pressure in tank.
  8.  Slowly add unleaded fuel to red max fill indicator in fuel 

tank. Be careful not to fill above the indicator. This allows 

adequate space for fuel expansion.

  9.  Install fuel cap and let any spilled fuel evaporate 

before starting engine.

High Altitude

At altitudes over 1524 m, a minimum 89 RON (85 octane/85 

AKI) fuel is acceptable. To remain emissions compliant, 

high altitude adjustment is required. Operation without this 

adjustment will cause decreased performance, increased 

fuel consumption, and increased emissions. 
See an authorized Briggs & Stratton dealer for high altitude 

adjustment information. Operation of the engine at altitudes below 

762 m with the high altitude kit is not recommended.

Transporting

When transporting equipment, turn fuel valve to off ( ) 

position. Do not tip engine or equipment at an angle which 

causes fuel to spill.

Operation

Max Fill Indicator

Oil Fill Cap/

Dipstick

Summary of Contents for 030807

Page 1: ...Number ______________________________ Revision ___________________________________ Serial Number _______________________________ Date Purchased _____________________________ Copyright 2020 Briggs Stra...

Page 2: ...rating compatible electrical lighting appliances tools and motor loads The generator s revolving field is driven by a single cylinder engine To move generator press button and pull handle out Press bu...

Page 3: ...r 10 seconds InfoHub Portable Wireless App Download the InfoHub Portable App to pair the Bluetooth enabled generator to your approved Android or iOS smartphone and follow the in app instructions The g...

Page 4: ...engine Check oil level with dipstick Maintenance Cover Remove to gain access to the choke lever spark plug and air cleaner Oil Drain Plug Drain engine oil here Oil Fill Cap Dipstick Check and add eng...

Page 5: ...hutdown due to carbon monoxide accumulation around the generator or a CO shutdown system fault occurred Circuit Breaker A push to reset circuit breaker is provided to protect the generator against ele...

Page 6: ...N o t f o r R e p r o d u c t i o n 6 BRIGGSandSTRATTON com au Exhaust muffler Point away from home Features and Controls...

Page 7: ...ll be exposed to carbon monoxide gas Operate portable generator only outdoors at least 6 1 m from occupied spaces with exhaust pointed away to reduce the risk of carbon monoxide accumulating Install b...

Page 8: ...generator must be at least 1 5 m from any structure overhang trees shrubs or vegetation over 30 5 cm in height Do not place portable generator under a deck or other type of structure that may confine...

Page 9: ...h Altitude for 1524 m and above WARNING Fuel and its vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Do not refuel during operation Do not smoke dur...

Page 10: ...over and position the choke lever to the middle position The e choke will automatically turn the choke off once the generator starts Reinstall maintenance cover NOTICE If engine starts but fails to ru...

Page 11: ...Equipment only 12 Volt DC Receptacle The maximum current available for the 12 Volt DC receptacle is 60 Watts 5 Amps A DC circuit breaker protects this receptacle from overloads If an overload occurs t...

Page 12: ...e to consider starting watts in generator capacity Carbon Monoxide CO Shutdown System Automatically shuts down the engine when harmful levels of carbon monoxide accumulate around the generator or a CO...

Page 13: ...uel leaks Clean any accumulated debris Keep area around muffler free from any debris Use a soft bristle brush to loosen caked on dirt or oil Use a damp cloth to wipe exterior surfaces clean NOTICE Imp...

Page 14: ...il into oil fill opening to the point of overflowing 6 Replace and tighten dipstick NOTICE Do not attempt to crank or start engine before it has been properly serviced with recommended oil This could...

Page 15: ...d tighten screws 10 Reinstall the maintenance cover and hand tighten the cover screws Service Spark Plug Changing the spark plug will help your engine to start easier and run better 1 Loosen the two m...

Page 16: ...iner Then run the engine until it stops from lack of fuel WARNING Fuel and its vapors are extremely flammable and explosive which could cause burns fire or explosion resulting in death or serious inju...

Page 17: ...not connected or discharged 1 Turn fuel valve to on position 2 Fill crankcase to proper level or place generator on level surface 3 Clean or replace air cleaner 4 Fill fuel tank 5 Connect wire to spar...

Page 18: ...N o t f o r R e p r o d u c t i o n 18 BRIGGSandSTRATTON com au Notes...

Page 19: ...N o t f o r R e p r o d u c t i o n 19 Notes...

Page 20: ...e commercial use In Australia Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensat...