21/02/2019 16:23:00
LS-60 (4851)-Installation&Operation Guide - v0.3 ENG draft
.docx
3.2
Sequence for Displaying or Programming
1. Power up the unit while vehicle is stationary (no speed pulse present).
2.
Hold
the pink wire to ground (0V, e. g. to black wire).
3. Immediately release the PINK wire from ground after 3 RED/GREEN light flash cycles (within
less than 2secs).
4. There are then two modes available:
4.1. Enter
Display Mode
- Used to view current stored speed threshold setting:
(1) After a
single
GREEN light flash, immediately touch the PINK wire to ground (within
less than 2secs) then 3 RED/GREEN light flash cycles (Within 2 Seconds)
(2) The GREEN light will start to flash. Count the GREEN light flashes and refer to the
table above for the set speed threshold.
(3) Followed by 5 fast GREEN light flashes to confirm the end of the
Display Mode
.
(4) Return to
Normal Operation
with constant GREEN light.
4.2. Enter
Program Mode
- Used to change speed threshold setting:
(1) After a
double
GREEN light flash, immediately touch the PINK wire to ground (within
less than 2secs).
(2) The GREEN light will start to flash up to 10 times. Immediately touch the PINK wire to
ground once the count has reached the required number corresponding to the desired
speed threshold, see above table.
(3) Followed by 5 fast GREEN light flashes to confirm the end of the Program Mode.
(4)
Normal Operation
is resumed with constant GREEN light.
(5) It is recommended to check if the selected speed setting is correct via the
Display
Mode
.
3.3
Further Notes on
Display
or
Program
Mode
1. If an input signal (speed pulse) is detected on the GREEN wire (Speed Pulse Input) the
sequence for Displaying or Programming
cannot
be entered. The vehicle must be stationary.
2. If the correct sequence is not followed for
Display
or
Program Mode
the RED light will flash 5
times to indicate an error and
Normal Operation
will resume with previous setting.
3. After either the
Display
or
Program Modes
have finished, the PINK wire must be
disconnected from ground for at least 1sec before next sequence can be started again.
4
Specifications
Speed range
0 to 60mph / 100kmp
Speed pulse calibration
(see also speed Threshold table)
Based on 4 pulses per meter distance
Max. switched power output current
1.2A
Operating voltage range
9Vdc to 32Vdc
Input current
Typ. <0.03A (Switch Power Output off)
Max. <1.8A (Switch Power Output on state)
Polarity
Negative ground
Operating temperature range
-40°C to +85°C
Dimensions (without connector)
44mm x 64mm x 16mm
Weight (including connector tail)
approx. 35g
Vehicle mounting
Housing with opening lugs for fixing e.g. with a cable tie
Plug with cable tail, cable length
300mm +/- 20mm
Approvals:
CE, ECE Regulation No. 10 Revision 4
(“E-marking”), FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Any change or modifications not expressly approved by the responsible party responsible for
compliance could void the user’s authority to operate the equipment.