Brigade CVCFB5301 Installation Manual Download Page 2

3

2

Table of Contents

IMPORTANT–

Please Read and Follow!

• Make sure that incoming voltage is the same

as unit rating. An electric rating plate

specifying voltage, frequency, wattage,

amperage, and phase is attached to the

product.

• To reduce the risk of fire, electric shock, or

injury to persons, installation work and

electrical wiring must be done by qualified

people in accordance with all applicable

codes and standards, including fire-rated

construction.

• The installer should leave these instructions

with the consumer who should retain them

for local inspector’s use and for future

reference.

Your safety and the safety of others is

very important.

We have provided many important safety

messages in this manual and on your

appliance. Always read and obey all 

safety messages.

This is the safety alert symbol. This

symbol alerts you to hazards that

can kill or hurt you and others.

All safety messages will be preceded by the

safety alert symbol and the word“DANGER”

or “WARNING.”These words mean:

D A N G E R

You will be killed or seriously injured if

you don’t follow instructions.

W A R N I N G

You can be killed or seriously injured if

you don’t follow instructions.

All safety messages will identify the 

hazard, tell you how to reduce the chance

of injury, and tell you what can happen if 

the instructions are not followed.

Warnings & Important Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  3

Professional

Dimensions & Specifications (30” & 36” Professional) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  6

Dimensions & Specifications (30” & 36” Professional with flush mount trim) _ _ _ _ _ _ _ _ _ _ _ _  8

Cutout Dimensions (30” Professional & Professional with flush mount trim) _ _ _ _ _ _ _ _ _ _ _  10

Anti-Tip Dimensions (30” Professional & Professional with flush mount trim)_ _ _ _ _ _ _ _ _ _ _  11

Cutout Dimensions (36” Professional & Professional with flush mount trim)_ _ _ _ _ _ _ _ _ _ _ _  12

Anti-Tip Dimensions (36” Professional & Professional with flush mount trim) _ _ _ _ _ _ _ _ _ _ _  13

Dimensions & Specifications (Dual Professional) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  14

Dimensions & Specifications (Dual Professional with flush mount trim) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 18

Cutout Dimensions (Dual 30” Professional & Professional with flush mount trim) _ _ _ _ _ _ _  22

Anti-Tip Dimensions (Dual 30” Professional & Professional with flush mount trim)_ _ _ _ _ _ _ 23

Cutout Dimensions (Dual 30” & 36” Professional & Professional with flush mount trim) _ _ 24

Anti-Tip Dimensions (Dual 30” & 36” Professional & Professional with flush mount trim) _ 25

Cutout Dimensions (Dual 36” Professional & Professional with flush mount trim)_ _ _ _ _ _ _ _ 26

Anti-Tip Dimensions (Dual 36” Professional & Professional with flush mount trim) _ _ _ _ _ _ _ 27

Cabinet Information (Professional) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 28

Cabinet Information (Professional with flush mount trim) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 30

Custom Side Panel Dimensions (Professional) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 32

Custom Side Panel Dimensions (Professional with flush mount trim) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 33

General Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34

Unpacking & Moving _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 36

Flush Mount Side Trim Installation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 37

Installation_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 37

Hinge Adjustment _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 38

Kickplate Installation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 40

Door Stop Adjustment _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 41

Final Installation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 41

Performance Checklist _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 43

Control Panels _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 44

Service & Registration_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 45

Summary of Contents for CVCFB5301

Page 1: ...111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at www brigade ca F21128 EN 030113 BRIGADE TM Installation Guide All Ref...

Page 2: ...6 Professional Professional with flush mount trim ___________ 13 Dimensions Specifications Dual Professional ____________________________________ 14 Dimensions Specifications Dual Professional with fl...

Page 3: ...r turn power disconnect switch to OFF position before removing top grille Failure to do so can result in death or electrical shock W A R N I N G TIP OVER HAZARD Appliance is top heavy and tips easily...

Page 4: ...t 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 9 1 amps 5 7 amps Inlet water requirements 1 4 copper tubing inlet waterline minimum 20 psi N A maximum 120 psi Overall i...

Page 5: ...ire cord with grounded 3 prong plug attached to product Maximum amp usage 9 1 amps 5 7 amps Inlet water requirements 1 4 copper tubing inlet waterline minimum 20 psi N A maximum 120 psi Overall interi...

Page 6: ...ax to bottom of anti tip board 23 58 4 cm 3 1 2 8 9 cm 3 7 6 cm 23 58 4 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions 11 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height...

Page 7: ...1 2 3 8 cm x 3 1 2 8 9 cm 29 1 2 74 9 cm 3 1 2 8 9 cm 3 7 6 cm 29 1 2 74 9 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions 13 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening hei...

Page 8: ...30 30 76 2 cm 76 2 cm 30 76 2 cm 26 1 2 67 3 cm Dimensions 15 24 61 0 cm 1 2 54 cm Between Units 9 5 32 23 3 cm 82 3 4 210 2 cm min to 84 1 16 213 5 cm max 20 3 4 52 7 cm 22 3 16 56 4 cm 75 15 16 192...

Page 9: ...66 7 cm 71 5 8 181 9 cm Cutout height 82 7 8 210 5 cm min to 84 1 16 213 5 cm max Cutout depth 24 61 0 cm min Electrical requirements 2 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounde...

Page 10: ...2 54 cm Between Units 9 5 32 23 3 cm 82 3 4 210 2 cm min to 84 1 16 213 5 cm max 20 3 4 52 7 cm 23 3 8 59 4 cm 75 15 16 192 9 cm 3 19 32 9 1 cm 29 73 7 cm 29 73 7 cm 30 30 76 2 cm 76 2 cm 30 30 76 2 c...

Page 11: ...5 cm max Cutout depth 24 61 0 cm min Electrical requirements 2 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 30 Freezer 9 1 amps...

Page 12: ...8 4 cm 3 1 2 8 9 cm 3 7 6 cm 23 58 4 cm 23 58 4 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 23 58 4 cm Anti Tip Dimensions 23 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5...

Page 13: ...cm x 3 1 2 8 9 cm Flush Mount Anti Tip Location 29 73 7 cm 3 1 2 8 9 cm 3 7 6 cm 23 58 4 cm 29 73 7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 23 58 4 cm Anti Tip Dimensions 25 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210...

Page 14: ...7 cm 3 1 2 8 9 cm 3 7 6 cm 29 73 7 cm 29 73 7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 29 73 7 cm Anti Tip Dimensions 27 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5...

Page 15: ...overhang Door Wall 1 13 16 4 6 cm Space if 24 61 0 cm standard cabinet depth is used 3 4 1 9 cm Full end panel 24 61 0 cm Standard cabinet depth 1 3 4 4 4 cm Offset 5 16 0 8 cm Cabinet Information Pro...

Page 16: ...rd cabinet depth 25 63 5 cm countertop depth Wall 3 4 1 9 cm Full end panel Door Wall 1 2 5 cm space if 25 63 5 cm cabinet depth is used 3 4 1 9 cm Full end panel 25 63 5 cm Flush 1 2 5 cm space if 25...

Page 17: ...Mount Trim 33 3 4 1 9 cm End panel 5 32 0 4 cm 3 16 0 5 cm Back filler panel 22 7 16 57 0 cm 22 7 16 57 0 cm 22 1 4 56 5 cm 6 15 2 cm Optional kickplate notch Dimensions determined by cabinets 82 7 8...

Page 18: ...rough doorways Floors can support unit s weight plus food weight approximately 1200 pounds 540 kg per unit Floors underneath refrigerator are level with surrounding finished floor Rear wall is solid a...

Page 19: ...rdboard shipping material to protect floor surface when installing unit Remove anti tip board kickplate and door trim pieces DF models from rear of unit 36 Moving Unit Remove shipping brackets from sk...

Page 20: ...3 3 3 10a Plug in power cord to verify operation Note Make sure power switch and showroom switch are in the On Position Place unit within 3 of being flush with cabinets Note To avoid cabinet damage pl...

Page 21: ...sing a Phillips screwdriver attach the kickplate to the unit and adjust to desired height 14 15 Wall 2 x 4 Refrigerator Screw 16 17 1 2 18 2 3 19 Kickplate Installation 3 1 2 20 1 2 21 110 120 90 Open...

Page 22: ...nserted Verify icemaker bailarm is down Verify dispenser operation if applicable h Align square door s h Verify drain pan is properly installed and there are no leaks in water connection h Install kic...

Page 23: ...nt indicator and alarm To exit the Sabbath Mode B Press and hold Activate Controls and then Display Off for 3 seconds The control will beep three times to alert the user the Sabbath Mode has been exit...

Page 24: ...47 46...

Reviews: