Brigade CRDSCD230-5B Installation Manual Download Page 4

7

Dimensions

6

Note: 

Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and not certified by CSA.

Clearances to non-combustible materials must be approved by the authority having jurisdiction.
Minimum clearances from adjacent combustible construction:
  Below cooking surface (36” [91.4 cm] and below)

• Sides - 0”  
•  Top grate support - 36” (91.4 cm)

Above cooking surface (above 36” [91.4 cm])

•  Sides - 6” (15.2 cm)
•  Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm)

above cooking surface

•  Wall cabinets directly above product must be a minimum of 42” (106.7 cm) above cooking surface
• Rear - 0” with 6  ” backguard or high shelf; 0” with island trim and non-combustible rear wall;
• 6” (15.2 cm) with island trim and combustible rear wall

Dual Fuel 30” W. Range

Description

CRDSCD230-5B

Overall width

29-7/8” (75.9 cm)

Overall height

To top of side trim – 35-7/8” (91.1 cm) min. 37” (94.0 cm) max.

Legs adjust – 1-1/8” (2.9 cm)

Overall depth
from rear

To front of side panel – 25” (63.5 cm) 

To front of door – 25-3/4” (65.4 cm)

To front of control panel – 27 1/8" (68.9 cm)

To end of knobs – 29" (73.7 cm)

Additions to Overall
Height

To top of island trim – add 0” (0.0 cm)

To top of backguard – add 6” (15.2 cm)

To top of high shelf – add 18-3/16” (46.2 cm)

Gas Requirements

Shipped Natural or LP/Propane, field convert with conversion kit (purchased separately);

accepts standard residential 1/2” (1.3 cm) ID gas service line

Gas Manifold Pressure

Natural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.

Electrical Requirements 240-208 VAC 60 Hz electrical connection box on product, connect with locally supplied

3-wire, flexible cord or “pigtail” rated 40 amp. 125-250 VAC minimum. Cord must be

agency approved for use with household electric ranges.

Max Amp Usage

240V

– 25.4 amps

208V

– 22.9 amps

Surface Burner Rating 
Natural/LP

Left front
Left rear
Center
Right rear
Right front

18,000 BTU Nat/15,800 BTU LP/Propane (5.3 kW Nat/4.7 kW LP/Propane)

8,000 BTU Nat/7,200 BTU LP/Propane (2.3 kW Nat/1.9 kW LP/Propane)
9,000 BTU Nat/8,000 BTU LP/Propane (2.7 kW Nat/2.3 kW LP/Propane)

12,000 BTU Nat/10,800 BTU LP/Propane (3.5 kW Nat/3.2 kW LP/Propane)
17,000 BTU Nat/15,000 BTU LP/Propane (5.0 kW Nat/4.4 kW LP/Propane)

Oven Interior Width

25-5/16” (64.6 cm)

Oven Interior Height

16-1/2” (41.9 cm)

Oven Interior Depth

Overall – 19-1/2” (49.5 cm)

AHAM – 16-13/16” (42.7 cm)

Oven Volume

Overall

AHAM

4.7 cu. ft.

4.1 cu. ft.

Approximate 

shipping weight 

410 lbs. 

(184.5 kg)

Specifications

29-7/8”

(75.9 cm)

35-7/8”

(91.1 cm) min.

to

37”

(94

.0 cm) max.

Dual Fuel 30” W. Range

35-7/8”

(91.1 cm) min.

to

37”

(94 cm) max.

25-3/4”

 

(65.4 cm)

45”

 

(114.3 cm)

19-1/4”

(48.9 cm)

24”

 

(61.0 cm)

25”

 

(63.5 cm)

29”

 

(73.7 cm)

6”

(15.2 cm)

25”

 

(63.5 cm)

2-3/8”

 (6.0 cm)

27-1/8”

 

(68.9 cm)

Note: 

Units shown with standard 6” backguard.

Summary of Contents for CRDSCD230-5B

Page 1: ...111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit us online at www brigade ca F21138 EN 030113 Freestanding 30 Dual Fuel Self Clean Sealed Burner Range Installation BRIGADE ...

Page 2: ...pen if the instructions are not followed WARNING CAUTION Warnings Important Safety Instructions_____________________________________________________3 Dimensions __________________________________________________________________________________6 Specifications ________________________________________________________________________________7 Clearance Dimensions Proximity to Cabinets _______________...

Page 3: ...efects or other reproductive harm To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed operated and maintained in accordance to the instructions in this document CAUTION To prevent possible damage to cabinets and cabinet finishes use only materials and finishes that will not discolor or delaminate and will withstand temperatures up to 194 F 9...

Page 4: ...uirements Shipped Natural or LP Propane field convert with conversion kit purchased separately accepts standard residential 1 2 1 3 cm ID gas service line Gas Manifold Pressure Natural 5 0 W C P Liquid Propane L P 10 0 W C P Electrical Requirements 240 208 VAC 60 Hz electrical connection box on product connect with locally supplied 3 wire flexible cord or pigtail rated 40 amp 125 250 VAC minimum C...

Page 5: ... This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the range hood installation instructions for additional information These dimensions provide for safe and efficient operation of the hood 66 min 167 6 cm to 72 max 182 9 cm 66 min 167 6 cm to 72 max 182 9 cm 24 61 0 cm or 27 38 6 cm 30 76 2 cm 6 15 2 cm Wood Composite Overlay Wood Compo...

Page 6: ...manual before work begins Pressure Regulator All heavy duty commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since service pressure may fluctuate with local demand External regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator ...

Page 7: ...e being used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed NOTICE DO NOT use the handle or oven door to lift the oven Remove door before installation to ensure that it is not used to lift the unit DO NOT lift or carry the door by the handle Removing the door must be done by your dealer a qualified licensed plumber or certified gas installer Door Removal CAUTION...

Page 8: ...h grounding product to the frame of the unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used WARNING ELECTRICAL SHOCK HAZARD To avoid risk of electrical shock personal injury or death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Electri...

Page 9: ... wire power supply cord kit rated for 40 amps 125 250 volts with closed loop terminals and marked for use with ranges Where local codes do not permit grounding through neutral use a 4 wire power supply cord The cord or conduit must be secured to the range with the strain relief bracket The electrical connection is made at the terminal block which is located behind the access door on the back of th...

Page 10: ...ft unit and prop on wood blocks 4 Feed supply cord up through hole in bottom of range back 1 2 5 1 2 6 Attach ground lead green with ground screw that was removed Attach line 1 red and line 2 black leads to outside terminal Attach neutral wire white to center terminal on terminal block 1 3 7 1 2 8 Push supply cord toward terminal block to relieve strain reattach supply cord strain relief bracket o...

Page 11: ...ST BE RE ENGAGED WARNING TIPPING HAZARD To reduce the risk of the appliance tipping it must be secured by a properly installed anti tip bracket s To make sure the bracket has been installed properly look behind the range with a flashlight to verify proper installation engaged in the rear top left corner of the range or under the range to verify that a floor hook and bracket have been installed You...

Page 12: ...nts section for proper installation information Connect gas and electrical Before placing appliance in operation always check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company Connecting Gas Electric DANGER GAS LEAK HAZARD To avoid risk of personal injury or death leak testing of the appliance must be conducted according to the manufacturer s i...

Page 13: ...clean cycle to unlock door Final Preparation All stainless steel body parts should be wiped with hot soapy water and with a liquid cleaner designed for this material If buildup occurs DO NOT use steel wool abrasive cloths cleansers or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wool or nylon scraper D...

Page 14: ...d it if service is ever required Model number ____________________________________________________________________________________ Serial number _____________________________________________________________________________________ Date of purchase __________________________________________________________________________________ Date installed ______________________________________________________...

Reviews: