Before securing machine to floor by tightening

hold-down bolts, make certain that all four cor-
ners are making contact with the floor after ma-
chine is leveled. If above condition is not met, it is
possible to twist the column and but a bind into
ways.

Ideally all milling machines should be bolted to

a concrete foundation. The machine should be
placed on a solid level floor with shims or
anti-vibration pads as shown in Figure 1.6 to
insure machine base is positioned evenly.

Leveling Machine

Set machine by leveling the work table

lengthwise and crosswise with a precision
instrument as shown in Figure 1.7.

M-450

1-5

Figure 1.6 - Foundation

Shim

TP5281

Figure 1.7 - Leveling the Machine

Level

Level

TP5282

Summary of Contents for HARDINGE TP5260

Page 1: ...INSTALLATION OPERATION MAINTENANCE AND PARTS LIST SERIES I MILLING MACHINES Revised August 29 2005 Manual No M 450 Litho in U S A Part No M 0009500 0450 June 2003 TP5260...

Page 2: ...ANING Thoroughly clean protective coating from the machine with a suitable cleaning solution WARNING DO NOT use gasoline or any other flammable cleaning agent to clean machine NOTE Do not move the tab...

Page 3: ...top pin back in Continue to raise the head attachment to vertical position Align the indicator on the head attachment with the ZERO line on the ram adapter scale Tighten all nuts first to 25 lb ft tor...

Page 4: ...er sling when lifting improper lifting could cause seri ous injury Note position of ram and table when lifting with sling Machine should be lifted by placing a sling under the ram as illustrated in Fi...

Page 5: ...is advisable to use a little grout thin mortar to take care of any unevenness in the concrete as well as to provide a solid foundation at all points When setting machine on a floor than has any surfac...

Page 6: ...deally all milling machines should be bolted to a concrete foundation The machine should be placed on a solid level floor with shims or anti vibration pads as shown in Figure 1 6 to insure machine bas...

Page 7: ...ired voltage against power supply to ensure that they are compatible 2 Connect machine wiring to power supply making sure connection is in compliance with safety regulations 3 Check for correct spindl...

Page 8: ...heads 3 Motor None required Motor greased for life of bearings 4 Grease with lubricate every six months as described on lubrication plate Not Shown Power Feed Oil to sight level with Mobilube No 46 S...

Page 9: ...ad to table in the longitudinal axis mount indicator as shown in Figure 1 9 For general milling use graduations provided on the head are close enough Tightening Sequence Tighten the four head locknuts...

Page 10: ...NOTES M 450 1 9...

Page 11: ......