Bridgecom Systems BRIDGE PRO 268U Manual Download Page 11

8

7.

 VOX Level

In standby, press the key programmed as" VOX Level", the radio will 
announce current VOX level. Press this key again to adjust VOX level or turn 
off VOX.

8.

 Scan

In standby, press the key programmed as "Scan", the radio will start scanning 
the list on the current channel location, press this key again to turn off the 
scan function.

9.

 Emergency Alarm

In standby, press the key programmed as" Emergency Alarm", the radio will 
start the alarm by its programmed method, press this key again to turn off 
alarm.

10.

 Record Switch

In standby, press the key programmed as" Record Switch", the radio will 
announce "Record on" and start voice recording, press this key again to turn 
off recording, the radio will announce "Record off".

Note

: The standard version supports 30 hours of voice recording for DMR 

channels.

11.

 Monitor

In standby, press the key programmed as "Monitor" function, the radio 
will turn off signaling and squelch level to monitor a weak signal or ID not 
matched signal. A repeat press of this key will turn off monitor. Note: In 
analog mode, the radio will emit white noise.

12.

 Send Alarm

In standby, press the key programmed as "Send Alarm" function, the radio 
will announce "Alarm" and Alarm Number 1-5 plus the alarm sound. A 
repeat press of this key can choose the Alarm Number, then press PTT to 
send the chosen alarm sound to a contact list or group members in current 
DMR channel.

Note

: This function only valid for DMR channel.

13.

 Hot key 1-6

In standby, press the key programmed as "Hot Key X " function to send 
signaling for 2TONE, 5TONE, DTMF, Remote kill, remote monitor, beep etc.

Summary of Contents for BRIDGE PRO 268U

Page 1: ...A1 210619 BridgeIP LLC 113 South Bridge Street Smithville MO 64089 Call us at 816 532 8451 Visit bridgecomsystems com for all of your radio support and education needs Printed in China...

Page 2: ...www bridgecomsystems com contactus bridgecomsystems com 816 532 8451 BRIDGE PRO 268U Manual...

Page 3: ...al of the BP 268U is to provide a cost effective feature rich easy to use radio This Owner s Manual will acquaint you with the features and operation of the BP 268U Every effort has been made in the p...

Page 4: ...nd Safety Warning Accessories Getting Acquainted Basic Operation Programmable Key Function Technical Specifications Warranty and Service FCC Warning and Compliance Statement Page 2 3 Page 4 Page 5 Pag...

Page 5: ...of this radio will result in user exposure far below the Occupational Safety and Health act OSHA and FCC limits DO NOT transmit for more than a 50 duty cycle example 1 min transmitting 1 min receiving...

Page 6: ...ur radio Unauthorized accessories may create unauthorized RF emissions or cause damage to the radio or may result in illegal operation Do not disassemble or modify the radio doing so will void the war...

Page 7: ...ck Charger AC Adaptor Belt Clip Wrist strap Instruction Manual 2 Charger Indication ACCESSORIES STATUS LED Self ExaminationWhen Powered on Red for 1 second No Battery Green Normal Charge Red Fully Cha...

Page 8: ...EY PF2 KEY PTT KEY GETTING ACQUAINTED MIC Indicator Status 1 Red light flashes Battery needs charged 2 Red light solid on Transmit 3 Green light flashe Scan mode 4 Green light on Receive matched carri...

Page 9: ...nnels per zone 4 Selecting a Channel Turn the channel knob clockwise to select channel positions 5 Receiving When the radio receives a digital signal the blue LED turns on When the radio receives an a...

Page 10: ...is function the radio will stop repeater communication 4 Revers In standby press the key programmed as Revers to turn on frequency revers function press this key again to turn off revers function Note...

Page 11: ...radio will announce Record off Note The standard version supports 30 hours of voice recording for DMR channels 11 Monitor In standby press the key programmed as Monitor function the radio will turn o...

Page 12: ...Deletion In standby press the key programmed as Phrase Playback Deletion the radio will announce Phrase playback and number and will start playing the voice recording during playback pressing the PTT...

Page 13: ...ort In standby press the key programmed as Status Info Report to turn on or turn off Status Report Status report Character time ID call type channel must be programmed by PC software Note This functio...

Page 14: ...D SK4BP 268 FCC Approvals CFR Title 47 Part 90 Private Land Mobile Radio CFR Title 47 Part 15 Subpart B Receiving Part Sensitivity 12dB SINAD 0 35 V Digital Sensitivity 0 3uV 117 4dBm BER 5 0 7uV 110d...

Page 15: ...eturned at the customer s expense and it will include the cost to ship test and return the equipment Equipment returned for repair must have a return merchandise authorization RMA number To obtain an...

Page 16: ...ncontrolled environment This radio has been tested and complies with the FCC RF exposure limits for Occupational Use Only Inaddition our radio complies with the following Standards and Guidelines with...

Page 17: ...ntion This radio complieswith IEEE and ICNIRP exposure limits for General Population controlled Environments RF exposure emvironment at operating duty factors of up to 50 and is authorized by the FCC...

Page 18: ...is equipment to radio or television reception can be determined by turning it off and then on The user is encouraged to try to correct the interference by one or more of the following measures Reorien...

Page 19: ...epresentative of the user of those services Replacement of any transmitter component crystal semiconductor etc not authorized by the FCC equipment authorization for this radio could violate FCC rules...

Reviews: