BRG DuraTime Installation And Operation Manual Download Page 3

 

 

 

DuraTime Clock Processor Configuration Menu 

 

Processor Type 

 
When the clock is displaying the time, Press the Up button to advance the time, or the Down button 
to decrement the time.  The longer the buttons are held down, the faster the time will change.  Press 
the Mode button to enter modes listed below. 
 

First Menu 

Level  

Mode Number 

Value 

Range 

Mode Description and Instructions 

 
Menu Selection 
 

 
Operating 
Value. 

 
1-

 

Press and hold the Mode button for 3-4 seconds, or until 01 appears on the 
display.  If the customer’s configuration was previously saved to secondary 
memory, all segments on all displays will illuminate while the mode button is 
held down.  

 
2-

 

Once in the menu system, use the Up and Down buttons to move to the 
desired parameter address.   

 
3-

 

Once at desired parameter address, press the Mode button once to display 
the parameter value.   

 
4-

 

Use the Up and Down buttons to change the parameter value.  

 
5-

 

Press the Mode button to return to the parameter address or press the 
Timer Control button to save any changes and exit the menu system.  

 
6-

 

To exit the menu system, press the Timer Control button, or use the Down 
button and move to parameter  address 00.  The clock will return to normal 
display mode.  

 

0. Change Time   00:00 to 

23:59 or 
12:00 AM to 
12:00 PM 

Simply press the Up button to advance the time, or the Down button to decrement the 
time.  The longer the buttons are held down, the faster the time will change.  Press the 
Mode button to enter modes listed below. 
 
 
 

 

 

 

1.  

01 to 31  
 

Day of the Month

 

Pressing the Up button advances the days, pressing the Down button decrements the 
days.   Be sure to use valid day for any specific month.  For example, do not enter a 
day of 30 for the month of February. 
 

 

 

 

2. 01 

to 

12 

Month 

Pressing the Up button advances the month, pressing the Down button decrements the 
month.    
 

 

 

 

3.  

00 to 50 

Year 

Summary of Contents for DuraTime

Page 1: ...Time Digital Clock Installation and Operation Manual BRG Precision Products 600 N River Derby Kansas 67037 http www DuraTimeClocks com sales brgproducts com 316 788 2000 Fax 316 788 7080 Updated 12 8 2011 1 ...

Page 2: ...Time master clocks Real Time Operation There is normally no configuration required to connect the DuraTime digital clock to the wireless network Simply apply power to the clock within radio range of an active DuraTime network and the clock will receive and update the display every second The Mega Real Time Clock employs a clock circuit with battery backup The clock circuit will maintain time for a...

Page 3: ...once to display the parameter value 4 Use the Up and Down buttons to change the parameter value 5 Press the Mode button to return to the parameter address or press the Timer Control button to save any changes and exit the menu system 6 To exit the menu system press the Timer Control button or use the Down button and move to parameter address 00 The clock will return to normal display mode 0 Change...

Page 4: ...ity 15 maximum intensity default 0 enable auto brightness if installed 1 to 15 alters the effect of auto brightness if installed 8 Adjust Time Received for Daylight Saving Time 0 disabled 1 enabled default Removes daylight saving time from serial time data received By default the clock expects to receive local time updates If daylight saving time is active then the time received will be decremente...

Page 5: ...conds left justified 2 hh mm hours and minutes default 4 nnnn four digit year 5 mm dd month and day 9 xxxx blank display 12 mm ss minutes and seconds 13 xssx seconds centered 17 dd mm international date format day month 20 hh mm hours and decimal minutes 21 1 99 Sets various display modes for the second display See Mode 20 for available display modes The default display format is 13 22 1 99 Sets v...

Page 6: ...play Format Display 1 Cycle Position 1 The display format will be displayed on display 1 in display cycle 1 See Mode 30 to adjust the time delay before switching display formats 32 0 99 Display Format Display 1 Cycle Position 2 The display format will be displayed on display 1 in display cycle 2 See Mode 30 to adjust the time delay before switching display formats 33 0 99 Display Format Display 1 ...

Page 7: ...his command will have no effect 94 NA Store user Parameters Into Secondary Memory All configuration parameters are automatically stored into primary memory This command stores the current clock configuration into secondary storage If the primary clock configuration becomes unusable the clock can be restored to the original user configuration using the command This avoids the necessity to re enter ...

Page 8: ...ogram loop the watchdog timer will automatically restart the clock The watchdog timer operation may be tested by placing the clock into an endless program loop Press the Mode button once to test the clock Once the Mode button is release the watchdog timer will reset the clock in two seconds and will return to normal display mode ...

Reviews: