background image

BR-1915G WASH ZOOM 19*15 Product Datasheet

 

BR-1915G WASH ZOOM 19*15 Product Datasheet

 

 

CAUTION ! EYE DAMAGES !

 

Avoid looking directly into the light source 

(meant especially for epileptics) !

 

 

1.

 

Safety instructions

 

Thank you for choosing our BR-1915G WASH ZOOM 19*15. FOR YOUR OWN SAFETY, PLEASE READ THIS 

USER MANUAL CAREFULLY

 

BEFORE YOU INITIAL START - UP!

 

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a 

safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in 

this manual.

 

 

 

 

Important:

 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual 

or any unauthorized modification to the device.

 

Please consider that damages caused by manual modifications to the device are not subject to warranty.

 

During the operation the housing becomes hot). Allow the fixture to cool approximately 20 minutes prior to 

manipulate with it.

 

Make sure that the available voltage is not higher than stated on the rear panel.

 

WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable to 

completely remove power from unit when not in use or before cleaning or servicing the fixture.

 

Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the power-

cord from time to time.

 

Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power-

cord by the plug. Never pull out the plug by tugging the power cord.

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.

 

The electric connection, repairs and servicing must be carried out by a qualified employee. Do not 

connect this device to a dimmer pack.

 

Do not switch the fixture on and off in short intervals as this would reduce th

e lamp’s life.

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 

necessarily mean that the device is defective.

 

Do not touch the device’s housing bare hands during its operation (housing becomes hot)! For 

replacement use lamps and fuses of same type and rating only.

 

 
 
 

 

Brighten Led Lighting Limited

 

Tel:86-020-84939726 
Fax:86-020-84939725

 

 

 

WWW. brightenfocus.com

 

E-mail:info@  brightenfocus.com

 

Brighten Led Lighting Limited

 

Tel:86-020-84939726 
Fax:86-020-84939725

 

 

 

WWW. brightenfocus.com

 

E-mail:info@  brightenfocus.com

 

CAUTION!

 

Keep this device away from rain and moisture! 

Unplug mains lead before opening the housing!

 

CAUTION!

 

Be careful with your operations.

 

With a high voltage you can suffera dangerous electric shock when touching the wires!

 

01

 

14

 

35 

 

 

 

Green in pixel 4 

0..255  Green in pixel 4 saturationcontrol(0-100%) 

36 

 

 

 

Blue in pixel 4 

0..255 

Blue in pixel 4 saturationcontrol(0-100%) 

37 

 

 

 

White in pixel 4 

0..255  White in pixel4 saturationcontrol(0-100%) 

 
 
 
 
 

 

38 

 
 
 
 
 

 

22 

 
 
 
 
 

 

16 

 

Special function 

0..19 

No function 

20..29 

No function 

30..39 

No function 

40..79 

No function 

80..89 

All Motor reset 

90..94 

SCANMotor Reset 

95..99 

ZOOM Motor Reset 

100..119 

Internalprogram1 

120..139 

Internalprogram2 

140..159 

Internalprogram3 

160..179 

Internalprogram4 

180..199 

Internalprogram5 

200..219 

Internalprogram6 

220..239 

Internalprogram7 

240..255 

InternalSound program 1 

 

Summary of Contents for BR-1915G

Page 1: ...cally and clean before they become clogged Clean two air filters placed in the fixture s covers and two in the fixture base Use a vacuum cleaner compressed air or you can wash them and put back dry After replacing the air filters reset the elapsed time counter in the menu Information Information Air Filters Elapsed Time Replacing the fuse Before replacing the fuse unplug mains lead 1 Remove the fu...

Page 2: ...ull out the plug by tugging the power cord This device falls under protection class I Therefore it is essential to connect the yellow green conductor to earth The electric connection repairs and servicing must be carried out by a qualified employee Do not connect this device to a dimmer pack Do not switch the fixture on and off in short intervals as this would reduce the lamp s life During the ini...

Page 3: ...ited Tel 86 020 84939726 Fax 86 020 84939725 WWW brightenfocus com E mail info brightenfocus com Brighten Led Lighting Limited Tel 86 020 84939726 Fax 86 020 84939725 WWW brightenfocus com E mail info brightenfocus com Euro Standard UKStandard USA Standard User Manual 1 Power Cable 1 Moving Head 1 Safety Cable 1 Hanging Kit 2 Signal Cable 1 13 02 22 Red in Pixel 1 0 255 Red in pixel 1 saturationco...

Page 4: ... 410 H mm Packing Dimensions 490 D 280 W 560 H mm Net Weight 11 2kg Gross Weight 13 9kg 03 12 21 21 Static patterns or patterns speed StaticPatterns IfPatternschannelisintheinterval016 031 000 015 staticscene1 016 031 staticscene2 032 047 staticscene3 048 063 staticscene4 064 079 staticscene5 080 095 staticscene6 096 111 staticscene7 112 127 staticscene8 128 143 staticscene9 144 159 static scene10...

Page 5: ...re using Keep the original packages if any second shipment is needed Don t try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies It is not in warranty range if there are any malfunctions from not following the user manual to operate or any illegal operation like shock short circuit electronic shock lamp broke etc Brighten Led Lighting Limited Te...

Page 6: ...sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Clamp Mounting BR 1915G WASH ZOOM 19 15 provides a unique mounting bracket assembly that integrates the bottom of the base and the safety cable rigging point in one unit see the illustration below When mounting this fixture to truss be sure to secure an appropriately rated ...

Page 7: ...e see illustrations below Brighten Led Lighting Limited Tel 86 020 84939726 Fax 86 020 84939725 WWW brightenfocus com E mail info brightenfocus com Brighten Led Lighting Limited Tel 86 020 84939726 Fax 86 020 84939725 WWW brightenfocus com E mail info brightenfocus com Power Switch Fuse DMX OUT POWER OUT POWER IN DMX IN DMX IN POWER IN Signal 3 Signal 2 1 Signal 1 2 Signal Ground 3 120 Ω DMX512 OU...

Page 8: ...ast 224 255 shutter open 8 8 8 Red 0 255 0 100 Reddimmerfromdarktobright 9 9 9 Green 0 255 0 100 Green dimmerfrom dark to bright 10 10 10 Blue 0 255 0 100 Bluedimmerfromdark to bright Function Mode Dmx Address A001 AXXX DMX address setting Channel Mode CH22 22Channel mode CH16 16Channel mode CH38 38Channel mode Auto Run Internal Program1 8 Master Alone Auto run Music Control Internal Program1 8 Ma...

Reviews: