background image

ETC120 TEMPERATURE CONTROLLER 

  INSTRUCTION MANUAL 

Version 1.0

BREWHA Equipment Co Ltd.

www.brewhaequipment.com

2017.1

P1/3

1. Overview

This temperature controller contains one temperature probe and
two independent outputs. One output is for cooling and the other
one is for heating. It can be used for applications such as heating
during mashing or fermentation, or for cooling post-boil and
during fermentation.

This controller is a plug and play controller. No wiring is needed
for the heater or cooler. Both the heating and cooling control
modes are simple on/off control, similar to a mechanical
thermostat but with much higher precision due to an adjustable
hysteresis band, precise sensor and digital read out. Anti-short
function is also provided for cooling to protect a refrigerator
compressor from being turned on while at high pressure which
could damage it.

Different operation temperature ranges of the two outputs can be
set separately. Once the cooling range is set, the controller
program will automatically limit the heating range to prevent both
heating and cooling from being turned on at the same time.

A digital silicon band gap sensor is used with the advantage being
that it is much more reliable in a moist environment than a
thermistor sensor. It can be immersed over an extended period of
time. It also has more uniform accuracy over an entire specified
temperature range.

2. Specification

SET

4. Setup Flow Chart

When the controller is plugged in, and the probe is attached, it
will display the measured temperature. The controller will keep
running according to the saved settings. If the temperature
sensor is shorted or removed, the controller will display “Err”.
Please see Figure 2 for the flow chart to set the parameters.

Up Key

Dn Key, Mute Alarm

Set Key

Measured

Temperature

Receptacle for

Cooling Device

Receptacle for 
Heating Device

Heating device
On Indicator

Cooling Device 

On Indicator

3. Front Panel

Figure 1. Front Panel

6

8.

9

5 sec

SET

H

SP

SET

A

H

SET

A

L

SET

C

DF

SET

H

DF

A

S

S

FA

O

FS

C

-

F

SET

SET

SET

SET

SET

6

8.

9

SET

Figure 2  
Set Up Flow Chart

Alarm High Limit

Alarm Low Limit

Cooling Differential

Heating Differential

Cooling Antishort

Sensor Failure

Operation

Temperature Offset

Temperature Unit

Displayed Temperature

Cooling 
Set Point

Heating 
Set Point

C

SP

Sensor Probe Connector

120V/12A Power Cord

Temperature Control Range

-2 to 105ºC/28 to 221ºF

Resolution

0.1º (from -9.9 to 99)

Accuracy

0.5ºC/0.9ºF

Control Mode

On/Off Heating and Cooling

Control Output

12A/120V

Audio Alarm

High and Low Limit

Sensor Type

Silicon Band Gap

Sensor Size

6mm/0.25”OD by 100mm/4”

Measuring Range

-2ºC/28ºF to 105ºC/221ºF

Ambient Temperature

-20ºC/-4Fº to 50ºC/122ºF

Dimension

91x140x46mm

3.5x5.5x1.75”

Input Power

15A/110-120V/60Hz

Sensor Cable Length

2.4m/8’

Power Cable Length

1m/3’

Warranty

1 year

Reviews: