ETC120 TEMPERATURE CONTROLLER
INSTRUCTION MANUAL
Version 1.0
BREWHA Equipment Co Ltd.
www.brewhaequipment.com
2017.1
P1/3
1. Overview
This temperature controller contains one temperature probe and
two independent outputs. One output is for cooling and the other
one is for heating. It can be used for applications such as heating
during mashing or fermentation, or for cooling post-boil and
during fermentation.
This controller is a plug and play controller. No wiring is needed
for the heater or cooler. Both the heating and cooling control
modes are simple on/off control, similar to a mechanical
thermostat but with much higher precision due to an adjustable
hysteresis band, precise sensor and digital read out. Anti-short
function is also provided for cooling to protect a refrigerator
compressor from being turned on while at high pressure which
could damage it.
Different operation temperature ranges of the two outputs can be
set separately. Once the cooling range is set, the controller
program will automatically limit the heating range to prevent both
heating and cooling from being turned on at the same time.
A digital silicon band gap sensor is used with the advantage being
that it is much more reliable in a moist environment than a
thermistor sensor. It can be immersed over an extended period of
time. It also has more uniform accuracy over an entire specified
temperature range.
2. Specification
SET
4. Setup Flow Chart
When the controller is plugged in, and the probe is attached, it
will display the measured temperature. The controller will keep
running according to the saved settings. If the temperature
sensor is shorted or removed, the controller will display “Err”.
Please see Figure 2 for the flow chart to set the parameters.
Up Key
Dn Key, Mute Alarm
Set Key
Measured
Temperature
Receptacle for
Cooling Device
Receptacle for
Heating Device
Heating device
On Indicator
Cooling Device
On Indicator
3. Front Panel
Figure 1. Front Panel
6
8.
9
5 sec
SET
H
SP
SET
A
H
SET
A
L
SET
C
DF
SET
H
DF
A
S
S
FA
O
FS
C
-
F
SET
SET
SET
SET
SET
6
8.
9
SET
Figure 2
Set Up Flow Chart
Alarm High Limit
Alarm Low Limit
Cooling Differential
Heating Differential
Cooling Antishort
Sensor Failure
Operation
Temperature Offset
Temperature Unit
Displayed Temperature
Cooling
Set Point
Heating
Set Point
C
SP
Sensor Probe Connector
120V/12A Power Cord
Temperature Control Range
-2 to 105ºC/28 to 221ºF
Resolution
0.1º (from -9.9 to 99)
Accuracy
0.5ºC/0.9ºF
Control Mode
On/Off Heating and Cooling
Control Output
12A/120V
Audio Alarm
High and Low Limit
Sensor Type
Silicon Band Gap
Sensor Size
6mm/0.25”OD by 100mm/4”
Measuring Range
-2ºC/28ºF to 105ºC/221ºF
Ambient Temperature
-20ºC/-4Fº to 50ºC/122ºF
Dimension
91x140x46mm
3.5x5.5x1.75”
Input Power
15A/110-120V/60Hz
Sensor Cable Length
2.4m/8’
Power Cable Length
1m/3’
Warranty
1 year