background image

Ultrasonic Humidification System

Instruction Book – CLI-AH300

by

Summary of Contents for Cli-Mate CLI-AH300

Page 1: ...Ultrasonic Humidification System Instruction Book CLI AH300 by ...

Page 2: ...E REFERENCE All components need to be installed in accordance with the user manual instructions for correct performance of unit This appliance should be used in conjunction with a safety switch This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instr...

Page 3: ...vice agent must make all service adjustments Unauthorised disassembling of the product will void the warranty Unplug from outlet when not in use and before cleaning Never plug in or unplug unit with wet hands Do not use unit outdoors or expose to greasy or damp environments Keep the rear air inlet and outlet free from air blocking materials such as clothing plastic bags or papers Air flow is requi...

Page 4: ... voltage indicated on the nameplate agrees with your voltage IMPORTANT SAFEGUARDS FOR ALL ELECTRICAL APPLIANCES Unwind the power cord fully before use Do not let the power cord hang over the edge of a bench or table touch hot surfaces or become knotted To protect against electric shock do not immerse power cord power plug or appliance in water or any other substance This appliance is not intended ...

Page 5: ...liance is recommended for household use only Do not use this appliance for anything other than its intended use Do not use in moving vehicles or boats Do not use outdoors Misuse may cause injury The installation of a residual current device safety switch is recommended to provide additional safety protection when using electrical appliances It is advisable that a safety switch with a rated residua...

Page 6: ...C D E F H I J K L A Mist Nozzle B Carry Handle C Water Tank D Water Inlet E Conditioning Cartridge F Water Tank Cover G Control Panel H Reed Switch I Transducer J Air Outlet K Base L Indicator Light M Scent Pad Tray M G ...

Page 7: ...death due to chemical burns and potential perforation of the oesophagus If you suspect your child has swallowed or inserted a button battery immediately call the 24 hour Poisons Information Centre on 13 11 26 for fast expert advice Examine devices and make sure the battery compartment is correctly secured e g that the screw or other mechanical fastener is tightened Do not use if compartment is not...

Page 8: ... Lithium battery To replace the battery open up the battery compartment at the back of the remote by forming a good grip of the remote pushing the small arched groove to the right and simultaneously pushing out the battery compartment cover by pushing the rectangular groove outwards See Fig 1a Insert the battery paying attention to the polarity and Reinsert the battery compartment into the remote ...

Page 9: ...t OFF 4th press Anion OFF and LED light OFF The default setting is Anion On and LED light ON the unit will return to default setting after the 4th press 9 To Set HUMIDITY LEVEL The LED display shows the current humidity level To set desired humidity press HUMIDITY button once and Co will flash on the LCD screen indicating Humidity has not yet been set Press again to set the desired humidity level ...

Page 10: ...he unit see Fig 2 Add a few drops of aroma essential oils on the pad Place the pad back into the tray and close NOTE Aroma essential oils not included Fig 2 PRODUCT SPECIFICATIONS ULTRASONIC HUMIDIFICATION SYSTEM MODEL CODE CLI AH300 POWER SUPPLY 220 240V 50 60Hz POWER CONSUMPTION Maximum 30W WATER TANK CAPACITY 5 Litres EVAPORATION RATE 300ml h on level 3 NOISE LEVEL 35dB ...

Page 11: ...r on the surface of the transducer Leave to soak for 2 5 minutes Use a cotton swab to gently loosen up the scale of the surface Rinse the transducer with clean water and wipe clean IMPORTANT Be careful not to damage the Transducer during cleaning Do not use any metal to scrape it or touch with bare fingers CAUTION Before carrying out cleaning or maintenance of the product always turn off and unplu...

Page 12: ...r instructions Water is too dirty or kept for too long in the tank Clean water tank and refill with fresh clean water Abnormal noise Very low water levels in water tank Refill water tank Unit is on an uneven surface Reposition the unit to a stable flat surface White dust accumulation Hard water used Follow instructions on page 5 Ensure that no foreign objects have fallen into the unit via the air ...

Page 13: ...13 Notes ...

Page 14: ...14 Notes ...

Page 15: ...15 Notes ...

Page 16: ...ue to continued product improvement the products illustrated photographed in this brochure may vary slightly from the actual product CLI AH300 ANZ A18 Web www breville co nz Web www breville com au Australian Customers Phone 1300 139 798 New Zealand Customers Phone 0800 273 845 Breville Customer Service Centre ...

Reviews: