1.  To operate the dehumidifier, press the 

 POWER button.

2.  The unit will start with a default fan speed 

of Medium and the humidity setting set to 

Continuous. 

3.  To turn the dehumidifier off, press the 

 POWER button again.

4.  The internal fan will continue to operate for 

4 minutes after the unit is turned off to cool 

the dehumidifier down.

NOTE

The dehumidifier cannot operate if the water 

tank is full or is not installed correctly.

NOTE

This dehumidifier produces heat during 

operation which may cause room temperatures 

to rise by 1°C to 4°C, especially if used in an 

enclosed space.

SENSAIR™ LIVE HUMIDITY CONTROL

• 

Your Breville All Climate™ Dehumidifier 

has a built-in sensor to detect changes in 

the humidity level in the air. This allows the 

unit to  keep the relative humidity (%) on the 

selected humidity level.

 

HUMIDITY SETTING

The default humidity setting for this  

dehumidifier is CONTINUOUS.
The Humidity Setting allows you to manually 

set the relative humidity (%RH) level between 

40%, 50%, 60% and CONTINUOUS. 
To select the humidity level, press the 

 HUMIDITY button until the light 

illuminates next to the desired level.  

When the selected humidity level is reached, 

the dehumidifier will switch to fan-only 

for 5 minutes to cool down, then stop. 

Every 30 minutes thereafter, the unit will 

operate on low speed to check the humidity.
If the humidity rises above the set humidity 

level, the dehumidifier will restart. 

NOTE

When using the Humidity Setting, the 

dehumidifier will turn off when the ambient 

relative humidity (%RH) is less than 2% of the 

level selected.

NOTE

The humidity level will only operate on 

Continuous when on High speed. 

 

FAN SPEED

The Fan Speed can be manually selected.
1.  Press the 

 SPEED button to cycle 

between Low, Medium (Med) and High. 

The light will illuminate next to the selected 

speed.

Summary of Contents for All Climate LAD250

Page 1: ...the All Climate Dehumidifier Instruction Book LAD250 ...

Page 2: ...d promotionallabelsbefore usingthedehumidifier for the first time Toeliminateachokinghazard foryoungchildren removeand safelydiscardtheprotective coverfittedtothepower plug ofthisdehumidifier Whenunpackingthe dehumidifier checktoseeyou havereceivedalltheitems listedinthepartslistbefore discardingthepackaging Thedehumidifier isintended forhouseholduseonlyandnot forcommercialor industrial use Donotu...

Page 3: ...ifierhas beendroppedordamaged inanymanner Returnthe dehumidifierto yournearest Brevilleservice centrefor examination electrical ormechanicaladjustment orrepair Donotusethedehumidifier withanexternaltimer programmer oranyother devicethatswitchesthe dehumidifieronautomatically sinceafireriskmayexistifthe dehumidifieriscovered orpositionedincorrectly Donotplaceanythingon topofthedehumidifierwhen asse...

Page 4: ...din thecleaninginstructions Theapplianceisnotintended forusebypersons including children withreducedphysical sensoryor mentalcapabilities orlackofexperienceand knowledge unlesstheyhave beengivensupervisionor instructionconcerninguse oftheappliancebyaperson responsiblefortheir safety Childrenshouldbesupervised toensurethattheydonotplay withtheappliance Itisrecommendedtoregularly inspecttheappliance...

Page 5: ...anceanditselectronic componentry Alwaysturntheapplianceto theoffposition switchoffat thepoweroutletandunplug atthepoweroutlet whenthe applianceisnotinuse FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS Beforecleaning alwaysturn theappliancetotheoff position switchoffatthe poweroutlet unplugatthe poweroutletandremovethe powercord ifdetachable fromtheapplianceandallow allpartstocool Donotplacethisapp...

Page 6: ...dy D Water Level Window E Base F Carry Handle G Air Inlet and Filter H Continuous Drainage Outlet Hole I Water Tank Not Pictured Drainage Hose gravity assisted Power Cord Water Tank Cover Continuous Drainage Outlet Dust Filter A B C D F G H I E Front Back ...

Page 7: ...ED HIGH 40 50 60 CONTINUOUS 1H ON 2H 4H 8H SPEED HUMIDITY ION FILTER TIMER Control Panel A Power On Off B Fan Speed C Humidity Setting D Timer G F A B C D E E Ion Filter On Off F Overheat Warning Light G Empty Me Warning Light ...

Page 8: ...a percentage of the maximum amount of water vapour that the air can hold at a given temperature A comfortable RH level is between 40 60 RH Assembly BEFORE FIRST USE 1 Before using your dehumidifier for the first time remove all packaging material and promotional labels 2 Check for any missing or damaged parts as per the components list 3 Clean all parts according to the Care Cleaning Storage secti...

Page 9: ...ty on the selected humidity level HUMIDITY SETTING The default humidity setting for this dehumidifier is CONTINUOUS The Humidity Setting allows you to manually set the relative humidity RH level between 40 50 60 and CONTINUOUS To select the humidity level press the HUMIDITY button until the light illuminates next to the desired level When the selected humidity level is reached the dehumidifier wil...

Page 10: ...not suitable for drinking Do not drink this water and do not serve to animals or use to water plants NOTE Ensure the water tank is fitted correctly or the dehumidifier will not operate ION FILTER The inoniser produces charged negative ions that attach to floating particles such as dust and allergens removing them from the air 1 Press the ION FILTER button to turn the ioniser On or Off TIMER If a t...

Page 11: ...ose should be above the level of the continuous drainage outlet WARNING Ensure the hose is secure in both the water outlet and the drainage outlet OVERHEAT WARNING This dehumidifier is equipped with Overheat Protection As the dehumidifier operates an obstruction blockage may occur in the air grilles causing the unit to overheat internally In this event the dehumidifier will turn off automatically ...

Page 12: ...er in the water tank into a drain 3 Rinse the inside of the tank with clean water 4 Wipe any excess water from the outside of the tank and the dehumidifier with a soft dry cloth 5 Place the water tank cover back on the water tank and then slide the tank back into the dehumidifier FILTER CLEANING Clean the filter at least monthly or more often if the dehumidifier is in frequent use NOTE A dirty fil...

Page 13: ... object that is blocking the air inlet or outlet Loud noises coming from the dehumidifier The dehumidifier is on an uneven surface Position the dehumidifier on a smooth and stable surface The dehumidifier suddenly stops The room temperature may be outside of the radar of the dehumidifier The dehumidifier will start automatically when it can read the room temperature again Clothing dries very slowl...

Page 14: ...14 Notes ...

Page 15: ...15 Notes ...

Page 16: ...e Customer Service Centre Breville the Breville logo Master Every Moment All Climate and SenSair are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2019 Due to continued product improvement the products illustrated photographed in this booklet may vary slightly from the actual product LAD250 ANZ A19 ...

Reviews: