3. Set up power supply for the remote sensor.

4. Position the base station and the remote sensor within the effective transmission range.

5. Ensure that the base station and remote sensor are assigned to the same channel.

When changing batteries always change batteries in the main unit as well as all remote units and re-
place them in the correct order, so the remote connection can be re-established. If either of the
devices is mains-powered, the power supply must be disconnected for a short moment also for this
device when exchanging the batteries. If batteries are exchanged in only one of the devices (i.e. the
remote sensor) the signal can’t be received or can’t be received correctly.

Note, that the effective range is vastly affected by building materials and position of the main and re-
mote units. Due to external influences (various RC devices and other sources of interference), the
maximum distance can be greatly reduced. In such cases we suggest to position the main unit and the
remote sensor at other places. Sometimes all it takes is a relocation of one of these components of a
few inches!

10 Setting up power supply

Base unit

1. Remove the battery compartment cover.

2. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.

3. Replace the battery compartment cover.

Remote sensor

4. Loosen the screw at the battery compartment cover with a small Philips screwdriver and remove

the cover.

5. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.

6. Replace the cover and retighten it with the screw.

Summary of Contents for Weather Center XXL JC + sensor 5in1

Page 1: ...Weather Station Weather Center XXL JC sensor 5in1 EN Instruction manual...

Page 2: ...ant le code QR ou le lien correspondant NL Bezoek onze internetpagina via de volgende QR code of weblink voor meer informatie over dit product of de beschikbare vertalingen van deze gebruiksaanwijzing...

Page 3: ...14 Automatic time setting 11 15 Manual time setting 11 16 Time zone setting 11 17 Receiving measurements automatically 12 18 Receiving measurements automatically 12 19 Rainfall 12 20 Manual measuremen...

Page 4: ...4 35 EC Declaration of Conformity 19 36 Cleaning and maintenance 19 37 Disposal 19 38 Warranty 20...

Page 5: ...in this documentation are gen erally protected by trade trademark and or patent law in Germany the European Union and or other countries 2 Validity note This documentation is valid for the products wi...

Page 6: ...button switch between highest low est or current value display 5 HISTORY button retrieve measurements for the past 24 hours 6 UP button increase value 7 DOWN button decrease value 8 TIME button manua...

Page 7: ...meter 7 Pipe clamp 8 Mounting shoe 9 Mounting bar 10 Battery compartment cover 11 RESET button 12 LED function indicator 13 Mounting screws with nuts 7 Scope of delivery Base station A power adapter B...

Page 8: ...ls like temperature wind chill dew point and heat index 14 Beaufort scale for wind force classification 15 Outdoor humidity 16 Sensor signal strength indicator 17 Outdoor temperature 18 Weather foreca...

Page 9: ...ote that the effective range is vastly affected by building materials and position of the main and re mote units Due to external influences various RC devices and other sources of interference the max...

Page 10: ...nt to the North Assembly on a vertical or horizontal wooden element 1 Slide one end of the assembly bar into the aperture below the sensor head 2 Slide one screw through the bore hole and put on the n...

Page 11: ...signal icon turns on If the clock fails to receive the time signal go ahead with the following steps 1 Press RCC button on the base station until radio signal symbol flashes 2 If the device is still...

Page 12: ...rainfall Monthly rainfall Select display mode Press the RAIN key repeatedly until the desired time period is shown on the display RATE Current precipitation of the last hour DAILY Total precipitation...

Page 13: ...ut a need to reset the clock and re establish pairing Simply press and hold the HIS TORY button for 10 seconds This will clear out any data recorded before 23 Pointing the sensor to the south The sens...

Page 14: ...n hemisphere it moves from left to right Below are the 2 tables which illustrate how the moon will appear on the main unit A 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 Illustration 4 A Northern hemisphere B So...

Page 15: ...next setting value 5 Press the UP or DOWN key to change the REL value according to the researched value 6 Finally press the CLOCK SET button to save the settings and exit the setting mode NOTICE ABS...

Page 16: ...88 km h 88 km h Select wind speed unit 1 Press the WIND button for approx 3 seconds to enter the setting mode 2 Press the UP or DOWN button to change the unit between mph miles per hour m s miles per...

Page 17: ...CHILL is displayed Note The wind chill factor is based on the common effects of temperature and wind speed The displayed wind chill is calculated solely from temperature and wind speed and is measured...

Page 18: ...Outdoor min temperature Outdoor max humidity Outdoor min humidity Indoor max temperature Indoor min temperature Indoor max humidity Indoor min humidity Outdoor max wind chill Outdoor min wind chill O...

Page 19: ...hermo hygro sensor 5 Unscrew the 2 screws at the bottom of the radiation shield 6 Gently pull out the shield 7 Remove carefully any dirt or insects inside the sensor casing Note The radiation shield c...

Page 20: ...hargeable batteries are marked with a symbol of a crossed out dustbin and the chemical symbol of the pollutant Cd stands for Cadmium Hg stands for mercury and Pb stands for lead 38 Warranty The regula...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...ail sav bresser fr T l phone 00 800 6343 7000 BRESSER France SARL P le d Activit s de Nicopolis 260 rue des Romarins 83170 Brignoles France Prix d un appel local depuis la France ou Belgique Service N...

Reviews: