12 Attaching rubber linings

Attach the supplied self-adhesive rubber pads to the clamps as shown to ensure a firmer fitting of the
mounting rod.

13 Assembling and installing the multifunctional

remote sensor

Depending on the desired location, the remote sensor can be installed in two different ways.

NOTICE! During the assembly make sure that the upper part of the wind vanve is minimum 1.5
meters off the ground. Use the circular level in the sensor head to ensure a level installation. The
windmill must point to the North.

Assembly on a vertical or horizontal wooden element

1. Slide one end of the assembly bar into the aperture below the sensor head.

2. Slide one screw through the bore hole and put on the nut on the opposite site. Tighten the screw

connection by hand.

3. Depending on the desired orientation, slide the opposite end of the assembly bar into the aperture

for vertical or horizontal mounting of the assembly base.

4. Slide another screw through the bore hole of the assembly base and put on the nut on the oppos-

ite site. Tighten the screw connection by hand.

5. Place the assembly base with its bottom site first on a wooden element. Use 4 wood screws to

tighten it.

Assembly on a vertical or horizontal tube

6. Repeat steps 1 to 4 as before.

7. Place the assembly base with its bottom site first on the tube. Push the tube bracket against the

tube from the opposite site.

8. Slide 4 screws through the bore holes of the assemby base and through the bore holes of the tube

bracket on the other site.

9. Put on the 4 nuts and tighten the screw connection by hand.

14 Signal transmission

The base station automatically connects to the multi outdoor sensor and (if available) to other wireless
sensors. You can also press the WIFI / SENSOR button to search directly for the sensors. If the
connection is successful, the outdoor symbol (OUT) and/or the channel will appear on the display.

Connection status display:

Connection status

Display indication

Good signal

Receiver symbol

Summary of Contents for 7002580

Page 1: ...Weather Station Wetterstation WI FI Colour Weather Station with 5in1 Multisensor EN Quickstart guide DE Schnellstartanleitung...

Page 2: ...s sobre este producto en un idioma determinado Entonces visite nuestra p gina web utilizando el siguiente enlace c digo QR para ver las versioneAs disponibles IT Desidera ricevere informazioni esausti...

Page 3: ...English 4 Deutsch 15...

Page 4: ...Union and or other countries 2 Validity note This documentation is valid for the products with the following article numbers 7002580 7002581 Manual version 0920 Manual designation Quickstart_7002580...

Page 5: ...pose a CHOKING HAZZARD This product contains small parts that can be swallowed by children There is a DANGER OF CHOKING These pose a CHOKING HAZZARD DANGER Explosion hazard Improper use of this produ...

Page 6: ...INDEX button display change between feels like temperature dew point heat index and wind chill index 6 WIND button display change between aver age and current gust 7 MAX MIN button switch between high...

Page 7: ...the multisensor 1 Rain gauge 2 Antenna 3 Circular level 4 Wind cups wind speed 5 wind vane wind direction 6 Thermo Hygrometer 7 Pipe clamp 8 Mounting shoe 9 Mounting bar 10 Battery compartment cover 1...

Page 8: ...y 10 Date 11 WI FI synchronisation 12 Frost warning enabled 13 Alarm enabled 14 Current time 15 Feels like temperature 16 Moon phase 17 Weekday 18 Graphical weather trend display 19 Humidity indoors 2...

Page 9: ...both the base unit and the outdoor sensor Sometimes a shift of just a few centimetres is enough 10 The first steps Follow the bullet points in order to ensure a successful setup 1 Setting up power sup...

Page 10: ...or horizontal mounting of the assembly base 4 Slide another screw through the bore hole of the assembly base and put on the nut on the oppos ite site Tighten the screw connection by hand 5 Place the...

Page 11: ...tem Devices 4 Under Your devices click on the link Create device and follow the instructions to create a new device For Model select the W100 Series option under CCL For Link type select the option Pr...

Page 12: ...er each re start 7 In Access Point Mode the WI FI SENSOR button can be pressed for 6 seconds to restore the previous settings WI FI connection status WI FI symbol is shown in the display WI FI symbol...

Page 13: ...ed devices Smart device with built in Wi Fi AP mode Access Point function PC or notebook Android or iOS smartphone tablet Supported internet browsers Internet browser that support HTML 5 20 EC declara...

Page 14: ...umulators and can return the batteries after use either in our sales outlet or in the immediate vicinity e g in the trade or in municipal collection points free of charge Batteries and accumulators ar...

Page 15: ...ion verwendeten Bezeichnungen und Markennamen der jeweiligen Firmen sind im Allgemeinen in Deutschland der Europ ischen Union und oder weiteren L ndern waren marken und oder patentrechtlich gesch tzt...

Page 16: ...berpr fen Sie das Ger t die Kabel und Anschl sse vor Inbetriebnahme auf Besch digungen Besch digtes Ger t oder ein Ger t mit besch digten stromf hrenden Teilen niemals in Betrieb nehmen Besch digte T...

Page 17: ...in Wasser tauchen Setzen Sie das Ger t keinen Ersch tterungen aus Verwenden Sie f r dieses Ger t nur Zubeh r und Ersatzteile die den technischen Angaben ent sprechen Nur die empfohlenen Batterien ver...

Page 18: ...ge 8 HISTORY Taste Messwerte der letzten 24 Stunden abrufen 9 CHANNEL Taste Kanalwahl 10 CLOCK SET Taste manuelle Zeiteinstellung 11 ALARM Taste Weckrufeinstellung 12 ALERT Taste u a Temperaturalarm e...

Page 19: ...Rohrschelle 8 Montageschuh 9 Montagestange 10 Batteriefach abdeckung 11 RESET Knopf 12 LED Funktionsleuchte 13 Montageschrauben mit muttern 7 Lieferumfang Basisstation A Netzadapter B Standfu C multif...

Page 20: ...ronisation 12 Frostwarnung aktiv 13 Weckruf aktiv 14 Aktuelle Uhrzeit 15 Gef hlte Temperatur 16 Mondphase 17 Wochentag 18 Grafische Wettertrend Anzeige 19 Innenluftfeuchtigkeit 20 Komfortindikator Kli...

Page 21: ...fehlen wir sowohl f r das Basisger t als auch den Au ensensor andere Standorte zu suchen Manchmal reicht schon ein Verschieben um wenige Zentimeter 10 Die ersten Schritte Befolgen Sie die Punkte in de...

Page 22: ...in die ffnung des Mon tagefu es f r eine horizontale oder f r eine horizontale Montage stecken 4 Eine weitere Schraube die Bohrung des Montagefu es schieben und auf der anderen Seite die Mutter aufset...

Page 23: ...s einge ben https weathercloud net 2 Unter Join us today die pers nlichen Benutzerdaten eingeben und Sign up anklicken 3 Nach erfolgreicher Registrierung und Verifizierung der E Mail Adresse unter dem...

Page 24: ...nach Router zu suchen Feld leer lassen wenn Registrierung noch nicht vorliegt und Eingaben zu einem sp teren Zeitpunkt vorgenommen werden sollen F r die manuelle Anlage sind weitere Router Information...

Page 25: ...tragungsreichweite 150 m Maximale Sendeleistung 25mW Temperatur Messbereich 40 C 60 C 40 F 140 F Barometer Messbereich 540 1100hPa Relative Reichweite 930 1050hPa Luftfeuchtigkeits Messbereich 1 99 Lu...

Page 26: ...e getrennt gesam melt und einer umweltgerechten Wiederverwertung zugef hrt werden Batterien und Akkus d rfen nicht im Hausm ll entsorgt werden Sie sind zur R ckgabe ge brauchter Batterien und Akkus ge...

Page 27: ......

Page 28: ...sav bresser fr T l phone 00 800 6343 7000 BRESSER France SARL P le d Activit s de Nicopolis 314 Avenue des Ch nes Verts 83170 Brignoles France Prix d un appel local depuis la France ou Belgique Servi...

Reviews: