20
frame of view. Please note: The camera will
show a smaller field of view as can be seen in
the eyepiece, which is normal. Maybe choose
a different magnification on the microscope to
adjust the field of view of the camera.
You can save images and video by clicking on
the button „Snap“ (single image) or „record“
(Video) respectively. The folder to save files
and the language settings of the software
can be adjusted. Click the button to enter
the options menu. Choose the resolution
of the camera from the „Live“ dropdown
menu. The resolution of the capture will be
adjusted accordingly. The brightness of the
image will be adjusted automatically. For best
results adjust the microscope illumination to
maximum brightness. To adjust the exposure
time individually, remove the tick mark from
„Auto Exposure“ and choose a different
exposure time from “Exposure target“.
For a good result you can adjust further values
from the menu „Color Adjustment“. Depending
on the exact model of your camera, certain
menu points in the software might be inactive
if not supported by the camera hardware.
i
Tip:
To use the MikrOkular long-
term we recommend it al-
ways be connected to the
same USB port.
11. Using the MicrOcular
11.1. Preparation
1. Slide a specimen under your microscope
and focus on it.
2. Remove the eyepiece and Barlow lens
from the eyepiece support and the dust
cap from your MikrOkular and install same
in the eyepiece supports instead of the
Barlow lens.
3. Start your PC if you haven‘t yet and connect
your MikrOkular to the USB port of your
computer.
Care and maintenance
Separate the device from the power supply
before cleaning (remove batteries)!
Only use a dry cloth to clean the exterior of
the device.
nOTe:
Do not use any cleaning
fluid to avoid damaging the
electronics.
Clean the lenses (eyepiece and/or lens) with
a soft and lint-free cloth only (e.g. microfibre).
nOTe:
Do not apply excess pressure
to the cloth so as to avoid
scratching the lenses.
To remove more stubborn dirt, moisten the
cleaning cloth with an eyeglass-cleaning
solution and wipe the lenses gently.
Protect the device from dust and moisture!
After use - in particular in situations of high
humidity - let the device acclimatize for a short
period of time, so that the residual moisture
can dissipate.
Troubleshooting
error
solution
No picture visible
switch light on
put condenser lens
in place
adjust focus
Specifications
system requirements (pC Ocular)
PC with dual core processor (2.8 GHz
minimum) or higher; Operating system
Windows 7/8/10; 4 GB RAM minimum; 2 GB
free HDD space minimum; free USB 2.0 port;
CD/DVD drive.