WEATHER CENTER

Instruction Manual

GB

IE

Summary of Contents for 433MHz

Page 1: ...WEATHER CENTER Instruction Manual GB IE...

Page 2: ...It was developed as an electronic medium for the use of multimedia services General Warning DANGER This device contains electronic components which operate via a power source power supply and or batte...

Page 3: ...r Umweltamt Dispose of the packaging materials properly according to their type paper cardboard etc Contact your local waste disposal service or environmental authority for information on the proper d...

Page 4: ...ty wind speed and direction rain amount and rain rate Main Console Unit The main console unit features a radio controlled atomic precision clock with alarm and weather forecast It measures indoor temp...

Page 5: ...er Forecast Sunny Partly Cloudy Cloudy Slight Rain Heavy Rain Snow and Unstable Weather Conditions Pressure Current or historical pressure mbar hPa mmHg or inHg Altitude or sea level pressure adjustme...

Page 6: ...put Remote Temperate and Relative Humidity with Trend Indication Indoor and outdoor temperature and relative humidity display C or F Temperature and relative humidity trend indication Dew point displa...

Page 7: ...are Components Fittings Main Console Unit Thermo Hygro Sensor Rain Sensor Funnel shaped lid with battery hatch Sensor base Bucket see saw mechanism Protective screen 4 screws for securing unit to grou...

Page 8: ...extreme weather conditions Place the unit in a shaded area such as under a roof Avoid placing the sensor near sources of heat such as chimneys Avoid any areas which collect and radiate heat in the sun...

Page 9: ...e anemometer onto a vertical surface using the fittings provided 5 To allow the main console unit to find the direction which the wind vane is oriented the following procedures are required i Insert t...

Page 10: ...ounting the console unit on a wall or vertical surface fold the table stand back into the unit and use the fitting provided Placement Tips Make sure that the console unit is within the receiving range...

Page 11: ...for setting parameters Shows records for moon phase UV temperature humidity rain and wind HISTORY ALARM CHART CHANNEL SNOOZE Shows history for sea level pressure Shows time alarms and alerts for tempe...

Page 12: ...main console unit press UP to cycle through the modes in a clockwise direction or DOWN to cycle through the modes in an anti clockwise direction Pressure and Weather Forecast Mode Current pressure tre...

Page 13: ...Icon Sensor Battery Status Indoor Temperature Channel temperature Temperature and Humidity Mode Icon Min Max display Temperature alert Channel and reception status Cycling display Indoor Humidity Cha...

Page 14: ...re Parameters during Initial Start Up Pressure and Weather Forecast Mode Setting up the Time Date and Language Clock and Alarm Mode Setting up the Location Data Sunrise Sunset Mode Optional Setting up...

Page 15: ...e initial start up of the main console unit all functions in Pressure and Weather Forecast Mode will be locked until the pressure settings are configured 1 Choose Pressure Units The unit icon inHg or...

Page 16: ...y 1 In all modes pressing HISTORY will toggle the sea level pressure display 2 When sea level pressure is displayed press HISTORY repeatedly to view sea level pressure data for each of the last 24 hou...

Page 17: ...based weather forecast is about 70 2 The weather forecasts may not necessarily reflect the current situation 3 The Sunny icon as applies to night time implies clear weather Understanding the Moon Phas...

Page 18: ...63 for a list of available codes Press SET to confirm your selection 4 If USR was chosen for city code Set Degree for Latitude You will be asked to enter your latitude in degrees Press UP or DOWN to a...

Page 19: ...me during alarm selection mode to return to normal clock display Setting up the Time Alarms 1 In Clock and Alarm Mode press ALARM CHART to select alarm which you wish to configure 2 Press and hold ALA...

Page 20: ...ock icon If RC reception is deactivated the triangular tower icon will disappear Icon RC Reception Strength Undefined data Reception failed for 24 hours Weak signal but can be decoded Strong signal No...

Page 21: ...e zone of the city and DST selection 5 Upon completion the display will be returned to Sunrise Sunset Mode Note Press and hold SET anytime during the setup to return to normal Clock and Alarm Mode All...

Page 22: ...re alerts have a 0 5 C hysteresis to prevent the alerts from sounding constantly due to small fluctuations near the alert value This means that after the temperature reaches the alert value it will ha...

Page 23: ...RM CHART to confirm your selection 4 Upon completion the display will be returned to the temperature alert selection screen Disabling when Temperature Alarms are Activated To Disable Temperature Alarm...

Page 24: ...value can be understood as inch hr or mm hr Resetting the Rainfall Statistics Memory In Rain Mode press and hold MEMORY to reset all rainfall statistics Setting Units for Rain Display inch or mm In R...

Page 25: ...is is to prevent the alerts from sounding constantly due to small fluctuations near the alert value This means that after the wind speed reaches the alert value it will have to fall below the alert va...

Page 26: ...tivate deactivate it Setting up the Wind Alerts 1 In Wind Mode press ALARM CHART to select alarm which you wish to configure 2 Press and hold ALARM CHART until alert and corresponding icon starts flas...

Page 27: ...sole unit and outer casings for the remote sensors can be cleaned with a damp cloth Small parts can be cleaned with a cotton tip or pipe cleaner Never use any abrasive cleaning agents and solvents Do...

Page 28: ...pliances The weather readings do not correlate with measurements from TV radio or official weather reports Weather data can vary considerably due to different environmental conditions and placement of...

Page 29: ...lines are caused by the production process of the casing and unfortunately are unavoidable They have however no effect whatsoever on the operation of the device EEC DECLARATION OF CONFORMITY Product B...

Page 30: ...SU San Francisco Calif SFO 8 SU Los Angeles Calif LAX 8 SU San Jose Calif SJC 8 SU Power Main unit use 4 pcs UM 3 or AA 1 5 V battery Remote Thermo hygro unit use 2 pcs UM 3 or AA 1 5 V battery Remot...

Page 31: ...BUD 1 SE Johannesburg JNB 2 NO South Africa Buenos Aires Argentina BUA 3 NO Kingston Jamaica KIN 5 NO City Code Time DST City Code Time DST Zone Zone Kinshasa Congo FIH 1 NO Oslo Norway OSL 1 SE Kuala...

Page 32: ...0 to 199 9mph 199 9 Km h 173 7 Knots 89 3 m s Wind Speed Accuracy 2mph 5 Wind Speed Starting Threshold 3mph Wind Gust Speed Display Update Interval 33 seconds Wind Gust Sampling Interval 11 seconds 1h...

Page 33: ...33...

Page 34: ...34...

Page 35: ...35...

Page 36: ...nderungen vorbehalten Errors and technical changes reserved Sous r serve d erreurs et de modifications techniques Vergissingen en technische veranderingen voorbehouden Con riserva di errori e modific...