13
Secure-Tec
Operating Instructions
After the socket outlet has been switched on, the
control light “Protection on” will light up, indica-
ting that surge voltage protection is effective. In
case of a direct lightning strike, due to the extre-
mely high energy generated, complete protection
of the connected devices cannot be guaranteed.
You can get the highest level of surge protection
with a multi-level concept consisting of coarse and
medium protection (installation technology) toget-
her with our fine protection per EN 61643-11 type
3. When the socket outlet is switched on, the
green indicator lamp lights up, showing that the
surge voltage protection circuit is active. If it does
not light up, an acoustic alarm will sound at the
same time and the sockets will be isolated from
the mains power supply. To check whether this
condition can be reset, press the 16 A automatic
circuit breaker. If this fails, the protection is spent
and the sockets will continue to be de-energised.
Insurance protection for connected devices
Brennenstuhl guarantees the surge characteristics
up to the technical specifications indicated on the
type label of the relevant product. If the product is
used correctly, Brennenstuhl assumes any repair
or exchange of all devices directly connected to
the surge protection product and that are proven
to have been damaged by surge, if the following
applies: damage must arise from the non-obser-
vance of the described protection function accor-
007812 Secure-Tec_007812 Secure-Tec Akustik-Alarm 1 15.06.16