MAINTENANCE
Regularly check the battery for damage.
TECHNNICAL DATA:
Operating voltage
230 V~ 50 Hz
Switch voltage
230 V~ 4.35 A
Switch outlet switching capacity
max. 1000 W
Protection class
IP44
Wireless signal range
max. 25 m
Frequency band
433.05 MHz – 434.79 MHz
Operating frequency
433.92 MHz
Max. transmitting power
≤
5 dBm
Ambient temperature
0 ° to 35 °C
Storage temperature
- 40 ° to 70 °C
Battery
12 Volt, Type A 23
EC-compliant
FAULT RECTIFICATION
18
RCS 1044 N Comfort
Fault
Cause
Repair
Function lamp (5) does
not illuminate when a
button is pressed.
Battery incor-
rectly inserted.
Insert the bat-
tery correctly.
Battery does not
have contact.
Press the battery
against the con-
tact terminals.
Battery is empty. Insert a new
battery.
Device is not
functioning
Switch outlet not
properly
connected.
Plug the switch
outlet firmly
into the outlet.
Device not
switched on.
Switch on the
device.