  To decrease misting, turn the 

water valve clockwise and back 
towards the 3 o’clock position.

b.  If there is not enough mist,  

the water valve output is not 
open enough. Turn the water 
valve counter clockwise by a 
few degrees until the cooling 
and misting  are ideal.

Control panel – Locking feature:

When the locking feature is activated 
only the power button will function, 
all other features will be locked.

1.  To activate the locking feature 

hold down the fan speed      and      
buttons for 5 seconds until the  
LED lights begin to blink. 

2.  The locking feature is now activated, 

the lights will continue to blink to 
indicate that the locking feature  
is on.

3.  This will lock: oscillation, atomizer, 

and fan speed. Power button       
will still function.

4.  To unlock the controls, hold down 

the fan speed      and      buttons 
for 5 seconds until the LED lights 
stop blinking.

Control panel – Memory feature:

The Breezer Oasys control panel is 
equipped with a memory feature.  
When it is powered off it will 
remember the settings of its last use.

When powered back on, it will 
resume the same oscillation, 
atomizer, and fan speed settings of 
its last use.

Control panel – Dim/Brighten  
LED lights:

The Power Breezer is equipped with 
a feature to dim/brighten the control 
panel’s LED lights:

To 

dim/brighten

 the control panel 

LED lights:

1.  Press and hold the atomizer  

button       for one second  
then release.

2.  The atomizer button’s      LED 

light will blink indicating you have 
initiated the dim/brightening 
feature.

3. 

To dim,

 repeatedly press the      fan 

speed button until the LED lights 
are dimmed to the desired level.

NOTE:

 The dimming feature’s lowest 

level will turn off the LED lights.

1. 

  To  brighten,

 repeatedly press the 

      fan speed button until the LED 
lights are brightened to the desired 
level.

2.  Press atomizer button      once 

to exit dim/brightening feature. 
Current settings are set and saved.

  

ENGLISH

Summary of Contents for AB10-A-OO-B

Page 1: ...USER MANUAL This manual covers the following models Firmware v3 4 AB10 A 00 G ABT10 A 00 G AB10 A 00 B ABT10 A 00 B AB20 A 00 G ABT20 A 00 G AB20 A 00 B ABT20 A 00 B...

Page 2: ...outdoors To get the most out of your Breezer Oasys become familiar with its features and functions as described in this manual SAVE THIS MANUAL CONTENTS The Breezer Oasys 2 Warnings 3 Breezer Oasys Ov...

Page 3: ...t Do not leave unit unattended Children shall not play with the unit Cleaning and user maintenance shall not be made by children without supervision The unit is not to be used by persons including chi...

Page 4: ...4 Breezer Oasys Overview FRONT Atomizing Disc Reservoir Fan Head Handle Caster Lock Front Casters Reservoir Cover ENGLISH...

Page 5: ...5 REAR Hand Guard Handle Control Panel Power Cord Storage ENGLISH...

Page 6: ...side Note Do not lift reservoir cover from the front Doing so may damage the cover Breezer Oasys Reservoir Filling the reservoir Your Breezer Oasys reservoir holds up to 19 gallons of water which can...

Page 7: ...been filled to desired level and water valve output has been adjusted place reservoir cover back on the reservoir Gently tap reservoir cover back in place Draining the reservoir Depending on volume of...

Page 8: ...vate the oscillation feature 4 Press the atomizer button once to activate the misting feature Turning OFF your Breezer Oasys 1 Press the power button and hold for one second 2 The power button s light...

Page 9: ...Settings The mist setting is controlled by the water valve output located inside the reservoir tank Your Breezer Oasys will be shipped with the water valve output pre set at a low setting To increase...

Page 10: ...ghts stop blinking Control panel Memory feature The Breezer Oasys control panel is equipped with a memory feature When it is powered off it will remember the settings of its last use When powered back...

Page 11: ...n the water pump to maintain its proper function and to avoid damage 1 Gently pull front cover off to remove it 2 Remove locking ring by turning it counter clockwise 3 Gently pull impeller assembly to...

Page 12: ...on following de calcification product manufacturer s recommendation Replace the cleaning mixture with clean water and repeat steps 2 through 6 above to flush the system with clean water WARNING Failur...

Page 13: ...omerservice breezercooling com or 844 233 5673 Your Breezer Oasys shuts off 1 Unplug your Breezer Oasys 2 Wait 10 seconds then plug it back in 3 Restart your Breezer Oasys Your Breezer Oasys will not...

Page 14: ...te cool comfortable environments using water to cool down air but never get you wet To set your Breezer Oasys s mist to the perfect setting see adjusting your Breezer Oasys for your environment sectio...

Page 15: ...rformance of repairs or replacements THESE EXPRESS WARRANTIES ARE THE ONLY WARRANTIES BY MANUFACTURER ON THE BREEZER OASYS THESE WARRANTIES ARE LIMITED IN DURATION TO THE TIME PERIOD S OF THESE WRITTE...

Page 16: ...550 SW 12th Avenue Suite 550 Deerfield Beach Florida 33442 2016 Breezer Holdings LLC All Rights Reserved Breezer is licensed under U S Patent No 6 789 787...

Reviews: