12
www.breeze.com.vn | [email protected]
We bring better air to life
USER’S MANUAL
CDF/CDFS SERIES
FIXING ARRANGEMENT OF TERMINAL BLOCK
Terminal screw locknut
Terminal screw washer
Customers supply lead eyelet (when fitted)
Connecting links (when fitted)
Motor lead eyelet
Fixing
Torque values
M4
M5
M6
M8
M10
1.5Nm - Brass
2.7Nm - Brass
5.5Nm - Brass
10.5Nm - Brass
55.5Nm - Steel
Terminal screw
Terminal block
Identification tag
Brass washer
(Fitted with connecting links)
Terminal screw lockwasher
Important note:
This drawing shows the correct assembly sequence of terminal parts.
It is essential that no lockwashers or nuts are placed between the motor
lead eyelet, connecting link or customers supply lead eyelet (when fitted).
Packing washers
(Omit from assembly where stud
thread continues to terminal block
surface)
Do not use copper wire links
It is essential to ensure that all fixings on the fan assembly are secure. When examining and checking the security of fixings during routine
maintenance, those fixings that have locking devices fitted or are painted over, need not be disturbed if they can be seen to be secure. Any
locking devices that are disturbed during maintenance must be discarded and replaced with new identical devices.
Thread forming screws must have locking compound applied when being reused. Those fixings that have no locking devices fitted and
are not painted over, should be checked at 95% of their original setting to ensure no unnecessary disturbance of the fixing. See picture
below for torque setting details. If in doubt about the torque of a particular fixing contact Breeze Fan for advice.
Torque settings for screws
Screw Fixing
Torque setting: +0% / -10%
(Nm)
M4
M5
M6
M8
M10
M12
M14
M16
M18
M20
M22
M24
Steel 8.8
Stainless Steel
A2, A4 Prop 70
Stainless Steel
A2, A4 Prop 80
3.5 7.0 12 28 55 100 155 245 335 475 645 820
2 4 7 17 33 56 90 135 190 268 365 460
3 5.5 9.5 22 43 75 120 185 255 355 485 615
Torque settings for taper hubs
Bushes
Taper Hubs
Torque
Type
Bore
[mm]
Tightness
[Nm]
1008
1108
1210
1310
1610
2012
2517
12,19,24
19,24,28
16,19,24,32
14,25,35
19,24,38,42
24,38,50
38,48,60
6
6
20
20
20
32
49
Base and Foot
Mount Torque
Settings
(Nm)
Motor Frame
Screw Fixing
Motor Base
D71
D80
Foot Mount
Shaft and
Fixings
D90
D100
D112
D132
D160/180
D200-315
M8
M10
M12
M12
M12
M16
M20
M24
15
15
35
55
55
135
240
50
85
85
85
180
350
450
450
Screw Fixing
M6
M8
M10
M10
M12
M16
M20
Motor Frame
D71/80
D90
D100
D112
D132
D160/180
D200-250
M24
D280-315
6
15
30
30
50
120
180
295
Torque Value
-
TORQUE SETTINGS FOR FIXINGS
5.8 Fixing