WKC05/02 PG. 5

  Adjustment of mechanical thermostat only requires 1/8 clockwise turn of screw to lower enclosure temperature. Screw
is located on front of unit. (See Fig. 1)

  The Sentry III set point (desired enclosure temperature) may be changed by pressing and holding the "SET" button
while pressing the "COOLER" or "WARMER" button.  When the "SET" button is pressed the readout will automatically
change and display the current set point temperature

  Should the operation of the cooling unit be interrupted by a power outage or by raising the set point temperature while
the unit is running the Sentry III internal delay will be activated and the unit will not restart for two (2) to three (3)
minutes.  NOTE:  This delay may also occur on initial power-up.

MAINTENANCE

  The 

BREEZAIRE

 cooling unit requires very little maintenance.  To keep the system operating at its top performance,

at least once every three months the condenser coil should be inspected and vacuumed to prevent air blockage.
Remove the large warm air exhaust grille located outside the enclosure where the warm air is discharged.  Use a vacuum
with a brush attachment to remove the lint or dirt that may reside between the aluminum fins. 

If the condenser coil

becomes blocked the unit will over heat causing a loss in cooling efficiency and will result in a failure of the
unit not covered under warranty.

ENCLOSURE PROBLEMS

  BREEZAIRE

 is extremely proud of the quality and reliability of its products.  Experience has shown that of the small

number of problems encountered, the large majority are due to improper unit selection or enclosure construction.
Should the cooling system be suspected of malfunctioning, check the temperature of the air being exhausted from the
warm air exterior grille.  If it is warm, the unit is working.  A further check may be made by comparing the temperature
entering the front grille on the cold side (Evaporator Intake) with that leaving from the bottom left side (Cold Air
Outlet)(see Fig.1).  If the air leaving the unit is 6°F or more colder than the temperature entering, the unit is working
properly.  In some cases, improper placement or installation may cause the unit's performance to be compromised.

  In situations where the ambient relative humidity is very low, the desired enclosure relative humidity may not be
achieved without adding moisture.  To add moisture to the enclosure only use slow, natural evaporation from a small
porous water container.  Do not use a humidifier.

  In some cases, improper placement or installation may cause the unit's performance to be degraded.  

The warm air

exterior side of the unit must have a constant supply of fresh air, less than 85oF.

  If the unit is exhausted into a

confined area with poor ventilation, it will not be able to reject the heat and moisture it is removing from the enclosure
and a malfunctioning unit will be suspected.  If an obstruction to the flow of fresh air into or from the cooling unit (see
Fig. 3) is stopped or restricted for any reason the unit could heat rather than cool the enclosure.

  NOTE:  Should this condition develop when using the Sentry III, the unit will turn off when the enclosure temperature
rises to approximately 75°F, the unit will not restart until the enclosure temperature is lowered to approximately 65°F or the
unit is disconnected and then re-connected to the power supply.  This feature is disabled for approximately 45 minutes
after the unit is connected or re-connected to a power supply.

  Proper sealing of the enclosure through the use of a vapor barrier and weather stripping cannot be over emphasized.  The
unit will not be able to maintain the proper conditions if fresh, moisture-laden air is constantly being introduced into an
improperly sealed enclosure.  Symptoms of this condition are; unit runs all the time with only a slight reduction in enclosure
temperature and/or water overflows from the unit.  One way of discovering gross air leaks is to stand inside the enclosure
with the lights off, allow your eyes to adapt to the dark and look for light showing through cracks in the walls or around the
door.  Also close the door on a piece of paper, if you can pull the paper through the door, that means air and moisture are
also entering into your wine cellar.  Because of the temperature difference between the inside and outside, very small
cracks can allow large amounts of outside air into the enclosure.  Please be aware that moisture will pass through solid
concrete, brick, paint, paper and wood.

Summary of Contents for WKC Series

Page 1: ... INSTALLED BY DATE While great effort has been made to provide accurate guidelines BREEZAIRE cannot warrant its units to properly cool a particular enclosure Customers are cautioned that enclosure construction unit location and many other factors can affect the operation and performance of the unit Therefore the suitability of the unit for a specific enclosure or application must be determined by ...

Page 2: ...es them ideal to be installed in cabinets and credenzas BREEZAIRE WKC series cooling units are not always recommended for converted closets Ask your dealer for details ENCLOSURE CONSTRUCTION GUIDELINES To use the below SIZING GUIDE the enclosure to be cooled must be built to the following minimum specifications If the enclosure cannot be built to these minimum specifications consult your BREEZAIRE...

Page 3: ...e it will begin to run within 5 minutes of being plugged in Allow it to run for a minimum of 15 minutes There should be a flow of cool air from the lower evaporator outlet side see Fig 1 and warm air should be flowing from the rear opening on the exterior grille side see Fig 3 If there is no airflow or no change in temperature on either side contact your dealer F BREEZAIRE units should NOT be inst...

Page 4: ...t up the cooling unit will reduce the temperature of the enclosure slowly The unit may run constantly or cycle off for short periods The time required to reach the desired temperature will vary depending on the enclosure s construction and contents The thermostat is factory set to approximately 55o Fahrenheit Unless the temperature falls below that desired do not change the thermostat setting for ...

Page 5: ...ay cause the unit s performance to be compromised In situations where the ambient relative humidity is very low the desired enclosure relative humidity may not be achieved without adding moisture To add moisture to the enclosure only use slow natural evaporation from a small porous water container Do not use a humidifier In some cases improper placement or installation may cause the unit s perform...

Reviews: