7
Model:
VFB80HLED2
ASSEMBLY INSTRUCTIONS (Continued)
2. A piece of wood (not provided) may be necessary
that is screwed in from below through the ceiling
board. Suggested size is H 4 in. x L 14 in. Position
the screws far enough away from the edge of the
ceiling board that it does not crumble and give way.
3. Unplug light and blower power from wiring panel.
Remove blower assembly, wiring panel and junction
box from housing.
4. Insert the duct (not provided) into the duct
connector and tape all ductworks connection
to make them secure and airtight by through
the ceiling opening. Using wire nuts (not provided)
connect house wires to fan wires as shown
in the connect wiring diagram on page 8.
5. Insert housing into ceiling opening and secure
housing by using three screws (Ø4x25mm).
Wood
H:4 in.
L:14 in.
2
3
4
5
6. Insert blower into housing by using three screws
and plug in light and blower power.
Screws
6