SPECIFICATIONS
53
11.3
Electric motor
Standard electric motor design is an enclosed three-phase asynchronous motor. A
thermal safety device to prevent motor overload is optional.
11.4
Variable Frequency Drive (VFD) (optional)
The Bredel Variable Frequency Drive (VFD) has been preprogrammed and only needs
to be connected to the mains.
Mounting position
IM 2001 (IM B5) flanged gearbox with keyed shaft in hori-
zontal position.
Motor adapter
Electric motor has been integrated in the gearbox housing,
by which the smallest possible dimension is achieved.
Optional motor adapter
Adapters in conformance with IEC-B5 or NEMA TC.
In case of doubt about the local applicable regulations for the drive connec-
tion, contact your Bredel representative.
Protection class
IP55/IK08
Insulation class
F
Increase in temperature
Within class B
Voltage/frequency
230/400 V - 3 phases - 50 Hz
RFI filter
Integrated RFI filter B (industrial applications).
Control
Manual control for setting the speed and the keys for starting
forward, stop and starting reverse.
Protection class
IP65
Mains power supply
There are three types available; the choice depends on the
local electricity grid:
•
200-240 V ± 10%; 50/60 Hz ± 5%; 1 ph
•
200-240 V ± 10%; 50/60 Hz ± 5%; 3 ph
•
400-480 V ± 10%; 50/60 Hz ± 5%; 3 ph
Summary of Contents for Hose pump Series
Page 2: ...2...
Page 3: ...3 Hose pump series Bredel 10 Bredel 15 and Bredel 20 Manual...
Page 65: ...NOTES 65 Notes NOTES...
Page 66: ...NOTES 66...