6
Ussc
ASSEMBLY INSTRUCTIONS
Combustion Air Intake
This appliance requires a source of combustion air. If you home is of tight construction or has nega-
tive pressure problems, you will need an outside source of air.
You have two options. You may cut a rectangular hole in the fl oor of your home and the fl oor protector, or
purchase a standard 4” Dryer Vent kit from your local hardware supply store and install it on the rear of the
pedestal.
If your choice is to cut a rectangular hole in the fl oor and fl ooring protector, refer to the below illustrations for
assistance. You must place a rodent screen between the fl oor protector and the fl oor to prevent passage of
any unwanted vermin into your home.
If using a Dryer venting kit, the outlet cover must be of a design that DOES NOT close by means of
a fl ap or trap door.
You must purchase a style that allows a continuous in-fl ow of air and that has a rodent
screen. You will also need a Combustion Air Adapter to attach to the pedestal of the appliance. This adapter
can be purchased from your dealer.
If your home is not of tight construction, you can just simply remove the 4” round knockout in the rear of the
pedestal.
“Combustion Air thru Unit Base” installation:
First, decide the location of the appliance. Then, cut a 2” x 6” rectangular opening in the fl oor protector
within the appliance base’s perimeter. Using the fl ooring protector as a template, position it in place
and mark onto the fl oor of your home where to make your next cut. Make the cut in your home’s fl oor
slightly larger than the 2” x 6” to accommodate any misalignment. Attach a piece of screen over the
hole to prevent any unwanted vermin entering your home. Complete your appliance install.
“Dryer Venting Kit” installation:
Begin by installing the 4” adapter to the rear of the appliance using the screws provided. If not already,
remove the round knock-out from the pedestal. Follow the manufacturer’s installation instructions for
attaching the dryer vent kit to the home. Then attach it to the adapter on the appliance.
“Combustion Air thru Unit Base” Installation
“Dryer Venting Kit” Installation
FLOOR PROTECTOR
Home’s Floor
Rodent Screen
Non-Combustible Floor
Make a 2” x 6” (51mm x 152mm)
cutout through both the floor
protector and home’s flooring
within the perimeter of the