![Brecknell DS 1000-LCD Operator'S Manual Download Page 16](http://html1.mh-extra.com/html/brecknell/ds-1000-lcd/ds-1000-lcd_operators-manual_2806437016.webp)
AWT35-100107 Rev AB
16/30
FMT
Print Out
Format
MULTPL
MULTPL
Com1 output content and format:
MULTPL
= default format.
See
SINGLE= only displayed content and
current status will be output, it’s
compatible with NCI-SCP01;
EH-SCP = command / response mode;
SCP-12 = only displayed content and
status will be output, it’s compatible with
NCI-SCP12(NCI3835);
Eh-sp2 =
See
Lfuulf / ------ = special characters. Do not
use.
SINGLE
EH-SCP
SCP-12
Eh-sp2
Lfuulf
Lfuu--
Lf--lf
Lf----
--uulf
--uu--
----lf
------
USB
Port
(com2)
BAUD.RT
600
9600
Sets the baud rate of com2
1200
2400
4800
9600
19200
BYT.FMT
8N1
8N1
Sets the bits format of com2
7O1
7E1
7O2
7E2
OUT.MOD
NONE
PRT.CMD
Sets the output mode of com2:
NONE = no communication;
CONT = continuous output;
PRINT = press PRINT key for output;
CMD = via print format command only;
PRT.CMD
= output with PRINT key and
print format command (
;
STABLE = output when the weight stable
condition is met (See
Note:
when set to
PRINT or CMD mode,
the weighing must be in stable condition.
CONT
CMD
PRT.CMD
STABLE