14
Troubleshooting
Symptom
Probable Cause
Remedy
The BreatheAudio remote control does
not change the functionality of the
keypad.
The batteries are bad or improperly installed.
Replace or reorient the batteries in the remote
control.
The output from the speakers is not as
good as it should be.
The positive and negative leads for the
speakers are not properly installed. The
speaker wires may not be making good contact
at the Allport™ hub.
Check each speaker wire connection at the
Allport™ hub. The proper orientation should be Left
-, +
and Right
-,+
. Make sure that each termination
is tight and making good contact with bare wire.
Specifications
Power Amplifier Section
Continuous Average Output Power
15W
T
wo channels driven, 30-20kHz
@ 1% THD
Rated Distortion (1/2 power)
0.40%
Rated Impedance
8 Ohms
Damping Factor
50+
Frequency Response (30-20kHz)
+/-3dB
Preamplifier Section
Input Impedance
50k
Input Sensitivity for rated power
330mV RMS
Input Overload
3V RMS
IR System
Source Outputs 2
Output Drive Current
100mA
Output Drive Voltage
12V
Compatible with single and dual emitters
NuVo reserves the right to change specifications without notice.
Power Requirements
P
ower Supply
120VAC/240VAC 50/60Hz
P
ower Consumption all
190VA (166W)
channels driven to full-rated power
P
ower Consumption average
88VA (70W) 1/8 power
operating conditions
P
ower Consumption no signal
14VA (10W)
USA Safety Listing
ANSI/UL-6500
Physical Specifications
Unit Size Millimeters
89 x 216 x 325
Unit Size Inches
3.5 x 8.5 x 12.75
Shipping Size Millimeters
190 x 305 x 394
Shipping Size Inches
7.5 x 12 x 15.5
Unit Weight Kilograms
3.5
Unit Weight Pounds
7.8
Shipping Weight Kilograms
5
Shipping Weight Pounds
11.8