McCANNALOK CRYOGENIC VALVE
Installation, Operation and Maintenance Manual
© 2020 BRAY INTERNATIONAL, INC. ALL RIGHTS RESERVED. BRAY.COM The Information
contained herein shall not be copied, transferred, conveyed, or displayed in any manner that would
violate its proprietary nature without the express written permission of Bray International, Inc.
17 of 18
McCANNALOK CRYOGENIC VALVE
Installation, Operation and Maintenance Manual
Table 4:
GLAND RETAINER NUT AND SEAT RETAINER
SCREW TORQUES (Lb-in)
Valve Size
Gland Nut
Seat Retainer Screws
NPS
150
300
150
300
3
60
60
100
100
4
60
60
175
175
6
80
120
100
175
8
80
140
175
175
10
110
190
175
300
12
130
220
300
300
Table 6:
LOCATING PLUG AND MOUNTING BRACKET CAP
SCREW TORQUE (Lb-in)
Valve Size
Locating Plug Mounting Bracket Cap Screws
NPS
150 & 300
150
300
3
2520
175
175
4
2520
175
175
6
2700
300
300
8
3000
300
756
10
4200
756
756
12
4200
756
756
Table 4:
GLAND RETAINER NUT AND SEAT RETAINER
SCREW TORQUES (Nm)
Valve Size
Gland Nut
Seat Retainer Screws
DN
150
300
150
300
80
7
7
11
11
100
7
7
20
20
150
9
14
11
20
200
9
16
20
20
250
12
21
20
34
300
15
25
34
34
Table 6:
LOCATING PLUG AND MOUNTING BRACKET CAP
SCREW TORQUE (Nm)
Valve Size
Locating Plug Mounting Bracket Cap Screws
DN
150 & 300
150
300
80
285
20
20
100
285
20
20
150
305
34
34
200
339
34
85
250
475
85
85
300
475
85
85
Table 5:
DRILL SIZE TO REMOVE TACK WELD
(inches)
Valve Size
Class
NPS
150
300
3
.234
15/64
.234
15/64
4
.234
15/64
.234
15/64
6
.234
15/64
.234
15/64
8
.234
15/64
.234
15/64
10
.234
15/64
.234
15/64
12
.234
15/64
.234
15/64
Table 5:
DRILL SIZE TO REMOVE TACK WELD
(mm)
Valve Size
Class
DN
150
300
80
6
6
100
6
6
150
6
6
200
6
6
250
6
6
300
6
6