background image

FLOW-TEK FTG SERIES

MANUAL GEAR OPERATOR

Installation, Operation, and Maintenance Manual

BRAY.COM

THE HIGH PERFORMANCE COMPANY

Summary of Contents for Flow-Tek FTG Series

Page 1: ...FLOW TEK FTG SERIES MANUAL GEAR OPERATOR Installation Operation and Maintenance Manual BRAY COM THE HIGH PERFORMANCE COMPANY...

Page 2: ...M The Information contained herein shall not be copied transferred conveyed or displayed in any manner that would violate its proprietary nature without the express written permission of Bray Internat...

Page 3: ...Manual Gear Operator Please understand the following examples of information used throughout this manual DANGER Indicates a potentially hazardous situation which if not avoided will result in death or...

Page 4: ...with tapered roller bearings on both ends Adjustable travel stops provide precise adjustment in both open and closed positions Weather proof seal caps ensure travel stop adjustment is operational thro...

Page 5: ...s required using valve mounting plate and supplied fasteners It is recommended to use a small amount of Anti seize on the threads during assembly Fasten bracket loosely Place mounting coupler onto the...

Page 6: ...e valve rotate the gear handwheel counterclockwise left The position indicator bolted to the rotating gear indicates the valve position and moves as handwheel is turned NOTICE Position Indicator of th...

Page 7: ...hey are protected by Buna weather seal caps shown in Image 3 Gears mounted at the factory are shipped fully set and no adjustment is needed If the gear has been removed replaced or the integrity of th...

Page 8: ...ding adjustment stop stud with Allen wrench in position tighten the counter nut Do not allow the adjustment stop stud to move Using the handwheel turn the valve to be 10 20 degrees unseated and close...

Page 9: ...lve bore For fully closed position loosen the counter nut while holding the adjustment stop stud with Allen wrench Image 2 Loosen the adjustment stop stud by turning counterclockwise Start closing the...

Page 10: ...ces O rings gaskets and shafts Cover inside of gear box with thin layer of grease as to prevent rust build up caused by condensation NOTICE Gear operators intended for marine service high humidity or...

Page 11: ...l statements technical information and recommendations in this bulletin are for general use only Consult Bray representatives or factory for the specific requirements and material selection for your i...

Reviews: