![BraunAbility Side-Entry Power Foldout built on the Hybrid Toyota Sienna Operator'S Manual Download Page 23](http://html1.mh-extra.com/html/braunability/side-entry-power-foldout-built-on-the-hybrid-toyota-sienna/side-entry-power-foldout-built-on-the-hybrid-toyota-sienna_operators-manual_2805275023.webp)
Page 21
OPERATION
Allow ramp to deploy
fully before boarding.
Failure to do so may
result in damage.
nearly horizontal position (ap-
proximately 6”- 8” above ground
level). The ramp continues to
slowly lower the remaining dis-
tance by the force of gravity.
Forcing the Ramp: Allow the
power ramp to deploy (unfold
and lower) fully before boarding
the ramp. Forcing the ramp out
or down during the deploy/stow
functions or boarding onto the
ramp before it is fully-deployed
may result in damage to the
ramp, motor assembly and/or
electronic controller.
Ramp Override Switch
Ramp Electrical Override
An electrical override feature is in-
corporated in the power ramp sys-
tem. The override by-passes the
electronic control system to electri-
cally power the ramp. The override
is available to deploy (unfold) and
stow (fold) the ramp.
The ramp override switch is located
on the bottom of the driver side C-
Pillar. Press and hold the top of the
ramp switch to deploy (unfold) the
ramp. Release the switch when
the ramp is fully deployed (stops).
Press and hold the bottom of the
ramp switch to stow (fold) the ramp.
Release the switch when the ramp
is fully stowed (stops).
Caution: If you stop pressing the
override switch before the ramp is
fully stowed, the ramp may free-fall.
Press and hold this switch
to stow the ramp.
Override switches are located at the
bottom of the driver side C-Pillar.
ELECTRICAL OVERRIDE
RAMP
KNEEL
UP
511271
STOW
DEPLOY
Note: Override switches are pro-
vided as a backup. The electron-
ic control system is the recom-
mend/primary control method for
mobility functions (control switch-
es detailed on pages 12-14).