background image

20

Possible side effects

Some people will experience slight discomfort (e.g. heat or redness of the skin) when using the device – 
this is normal. You may feel heat and tingling when activating the flash, followed by redness in the skin. 
This type of reaction usually disappears within 24 hours. Adverse reactions are usually immediate or 
appear within 24 hours. In rare cases, they may take up to 72 hours to appear. If you experience abnormal 
skin reactions please contact your physician.

Side effect

How to assess and react

Warm feeling or tingling sensations during 
treatment which typically disappear after a few 
seconds to a minute and decrease with continued 
use.

This is expected and normal for all IPL treatments. 
You can keep on using the device as instructed.

Discomfort or pain is intense during treatment or 
persists after a treatment.

Stop using the device and consult your physician 
before using it again.

Skin redness during or after treatment which 
disappears within minutes to several hours.

This is expected and normal for all IPL treatments. 
You can keep on using the device as instructed 
once skin redness has disappeared. 

Skin redness which does not go away within 
24 - 48 hours after treatment.

Stop using the device and consult your physician 
before using it again.

In very rare cases:

 

Swelling and redness around the hair follicle that 
disappears within two or three days.

You can keep on using the device as instructed 
once swelling and redness around the hair follicle 
has disappeared.

Swelling and redness around the hair follicle that 

does not 

disappear within two to three days.

Stop using the device and consult your physician 
before using it again.

Temporary changes in skin color (lightening or 
darkening).  

If your skin color changes, stop using the device 
and consult your physician.

Increase in hair growth in areas of treatment (more 
likely to be seen with subjects of Mediterranean 
descent).

If this increase persists over several treatments, 
stop using the device and consult your physician.

In case of adverse events please contact your national competent authority and the device manufacturer. 

Trouble shooting 

The following troubleshooting guide may help you solving initial problems you may experience with this 
device.

Problem

Solution

Power bars do not light up when treatment window 
is placed on the skin.

Make sure the device is connected to an electrical 
outlet. Press any button (4 or 5) to activate it. 
Ensure both skin tone sensors are in full contact 
with the skin. If needed, move the device in a way 
that both skin tone sensors get skin contact.

The device doesn’t work on small areas.

Use the precision head* (12) on small, hard-to-
reach areas (*if available). 
Make sure both skin tone sensors are in contact 
with the skin.

Flashing sequence slows down.

Device is in heat-protection mode. To get back to 
normal speed, allow device to cool down.

91590833_Victoria2_PL5_Euro1.indd   20

91590833_Victoria2_PL5_Euro1.indd   20

30.10.20   13:42

30.10.20   13:42

Summary of Contents for Silk-expert Pro 5

Page 1: ...X 20 A 91590833_Victoria2_PL5_Euro1 indd 1 91590833_Victoria2_PL5_Euro1 indd 1 30 10 20 13 42 30 10 20 13 42 Stapled booklet 148 x 210 mm 106 pages incl 6 pages cover Cover 4 4c Content 2 2c Pantone 8...

Page 2: ...eignet suitable appropri apto adequado adatto geschikt egnet passende l mplig sopii nicht geeignet not suitable non appropri uso no apto n o adequado non adatto niet geschikt ikke egnet ikke passende...

Page 3: ...nes and dark hair colors Please refer to the skin tone and hair color chart on page 3 to see if the device is suitable for you Description 1 Treatment window 2 SensoAdapt skin tone sensors 3 LED Power...

Page 4: ...have had a professional skin peel treatment on the area you wish to treat You have any of the above this device may injure your skin or make existing conditions worse You may experience side effects s...

Page 5: ...signs of damage In case of damage or cracks stop using the device Electric shock may result from using a damaged device In case of defects have the device checked and repaired by an authorized servic...

Page 6: ...one U high light intensity dark skin tone U low light intensity with fast flash rate no LEDs no skin contact U device will not flash red LED invalid skin tone U device will not flash Gentle mode Push...

Page 7: ...may increase the chance of producing adverse reactions If you feel intense pain stop treatment immediately and consult your physician before using the device again Treatment head s The standard head...

Page 8: ...such as tanning booths or solariums Avoid any activity or skin products that may irritate your skin for 24 hours after treatment This includes using hot tubs or saunas wearing tight fitting clothing u...

Page 9: ...You can keep on using the device as instructed once swelling and redness around the hair follicle has disappeared Swelling and redness around the hair follicle that does not disappear within two to t...

Page 10: ...not use if the handle the base station or the mains cord is damaged If you are in any doubt about the safety or suspect it is damaged in any way you must not use it Disposal The product contains recy...

Page 11: ...on the product commencing on the date of purchase Within the guarantee period we will eliminate any defects in the appliance resulting from faults in materials or workmanship free of charge either by...