57 – Outer barrier is not up and latched and
ground detect switch did not deactivate
(Century and Vista only)
58 – Outer barrier is not up and latched and the
platform is 3" above the ground
59 – Outer barrier is not up after pausing
platform travel
60 – The kickout gas springs are worn, replace
before using
75 – Low voltage detected; must turn off power
switch to reset LCD
77 – Vehicle secure interlock has not been
activated
90 – Position will be set if you keep holding the
button until it beeps
91 – Position is out of a predetermined
acceptable range of floor position
92 – Bridge switch is not made, needs adjusting
93 – Inner rollstop occupied switch is not made,
position needs to be moved or switch
should be adjusted
94 – Outer barrier is not made, fix and try again
95 – Outer barrier latch is not made (check for
jumper on Century and Vista lifts, check
latch on Millennium lifts)
99 – Controller program is not valid; replace
controller
Flashing Numbers
Flashing 65 – Unfold button is pressed
Flashing 66 – Fold button is pressed
Flashing 67 – Down button is pressed
Flashing 68 – Up button is pressed
Flashing 69 – Bridge switch is activated
Flashing 70 – Outer barrier latch switch is
activated
Flashing 71 – Ground detect switch is activated
Flashing 72 – Outer barrier up switch is activated
Flashing 73 – Inner rollstop up switch is activated
Flashing 74 – Inner rollstop occupied switch is
activated
Flashing 76 – Outboard barrier occupied switch
is activated
Flashing 78 – Threshold tape switch “A” is
activated
Flashing 79 – Threshold tape switch “B” is
activated
Flashing 80 – Position set button is pressed
Flashing 81 – Single function UP / FOLD /
CLOSE button is pressed
Flashing 82 – Single function OPEN / UNFOLD /
DOWN button is pressed
Flashing 87 – CLOSE button is pressed
Flashing 88 – OPEN button is pressed
Flashing 89 – Door full open switch is activated
(or jumper is installed on control
board)
LCD Lift Codes
Listed below are codes that the lift controller
outputs during lift operation. The codes will be
displayed on an LCD screen located on the lift
control board inside the pump module.
Non-Flashing Numbers
01 – Platform stowed
02 – Platform unfolding
03 – Platform unfolding paused
04 – Platform at floor level
05 – Platform beginning to lower
06 – Platform lowering (threshold cannot be
occupied from this point down)
07 – Outer barrier moving to horizontal
position
08 – Platform at ground level
09 – Outer barrier moving to vertical position
10 – Platform raising
11 – Platform raising paused at floor
12 – Platform folding (limited pressure)
13 – Platform folding (full pressure)
14 – Timed fold (cinching lift tite) or (anti-rattle
state)
15 – Platform folding stopped
16 – Paused fold
17 – Platform between ground and 3" above
ground
18 – Platform above 3"
19 – Outer barrier moving to horizontal
postion
20 – The doors are not fully opened (only
applicable when door operators are
installed)
21 – The doors are opening (only applicable
when door operators are installed)
22 – The doors are closing (only applicable
when door operators are installed)
28 – Illegal function/not defined
29 – Interlock fault not recognized (or has
been cleared but a motion button is still
pressed)
30 – Platform location unknown
31 – Platform location transition state;
attempting to locate position
35 – Two or more motion buttons are being
pressed
36 – The retention belt cannot be buckled
while trying to fold or unfold
37 – Motion button being pressed is not a
valid motion
50 – Outer barrier is not up above inboard
barrier locked position
51 – Threshold is occupied when platform is
1" or more below floor level
52 – Inner rollstop is not up and locked below
inner rollstop locked position
53 – Inner rollstop occupied sensor is not
activated between floor and inner rollstop
up position
54 – Outer barrier is occupied before it is up
55 – Outer barrier is not latched when above
the inner rollstop locked position
(Millennium only)
56 – Outer barrier is not up and latched and
bridge switch did not deactivate
32410
32201
32201
PLATFORM FOLD
RELIEF VALVE
ADJUSTMENT
Platform Fold
Relief Valve:
See service
manual for
adjustment
procedure.
30787
Improper handling
and/or servicing
procedures may
result in
electrostatic
discharge (ESD)!
ESD may result in
electronic module
damage.
C A U T I O N