Braun Aesculap Favorita II Maintenance And Care Download Page 13

Maintenance and care of the Favorita II and its blades

B. Braun Vet Care GmbH, July 2008

Greasing of the worm gear – do
not overfil gearbox as this will
cause grease to enter motor
section (only use special Aesculap
grease)

Do not use the clipper if the
ON/OFF switch cover is split as
this will cause dog hair to be
pulled into the switch and both
parts will have to be replaced.

It is most important that
worn gear levers are replaced
or poor cutting will result.

Summary of Contents for Aesculap Favorita II

Page 1: ...Maintenance and care of the Favorita II and its blades B Braun Vet Care GmbH July 2008...

Page 2: ...II is its unique blade system The pressure on the top blade can be adjusted according to the type of coat If the cutting quality is decreasing you can temporarily improve the efficiency by increasing...

Page 3: ...vorita II and its blades B Braun Vet Care GmbH July 2008 top blade bottom blade pressure plate plate spring knurled screw It is important that all components of the cutterhead are in good working orde...

Page 4: ...8 Thanks to the knurled screw the pressure onto the top blade can be regulated according to the type of coat If the cutting quality is decreasing you can temporarily improve efficiency by increasing t...

Page 5: ...t on the underside of a dog for smooth cutting If it pulls or snags adjust the screw down another quarter of a turn and the head will be set for work It is extremely important that this is done before...

Page 6: ...re GmbH July 2008 Cutterheads should be checked to make sure that there are no cracks or wear on the plastic pressure plate as this will lead to poor cutting The plate spring guarantees equal pressure...

Page 7: ...g the knurled screw Use a gentle brush for cleaning Then lubricate the blade with 2 or 3 drops of Aesculap special oil and assemble Blades should be oiled regularly when in use or overheating will occ...

Page 8: ...tenance and care of the Favorita II and its blades B Braun Vet Care GmbH July 2008 The top and bottom blades match to the respective blade They should not be interchanged even if they are of the same...

Page 9: ...nce and care of the Favorita II and its blades B Braun Vet Care GmbH July 2008 control electronics ball bearing motor motor carbons commutator fan gear lever on off worm gear with cam and bearing seal...

Page 10: ...II and its blades B Braun Vet Care GmbH July 2008 Carbons wear when in use and should be replaced when the old ones wear down to approx 0 2 inches 0 5 cm Do not run the clipper out of carbons as this...

Page 11: ...d its blades B Braun Vet Care GmbH July 2008 Carbon s wear when in use and should be replaced when the old ones wear down to approx 0 2 inches 0 5 cm Do not run the clipper out of carbons as this will...

Page 12: ...nd its blades B Braun Vet Care GmbH July 2008 field magnet with ON OFF switch armature with fan The components displayed on this page have to be rarely replaced The armature is coiled and produced in...

Page 13: ...earbox as this will cause grease to enter motor section only use special Aesculap grease Do not use the clipper if the ON OFF switch cover is split as this will cause dog hair to be pulled into the sw...

Page 14: ...des B Braun Vet Care GmbH July 2008 A worn gear lever cannot work correctly as it will cause a loss of power and movement to the top blade on the cutterhead The result would be poor cutting and sharp...

Page 15: ...and its blades B Braun Vet Care GmbH July 2008 swallow tail lever pressure spring swallow tail plate swallow tail The blade is held firmly to the clipper by the interaction of the swallow tail the pre...

Page 16: ...its blades B Braun Vet Care GmbH July 2008 Enjoy your work with the Favorita II The clipper that works as hard as you do V07202 B Braun Vet Care GmbH Am Aesculap Platz 78532 Tuttlingen Germany Phone 4...

Reviews: