background image

Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 31312 Rev. A

Cam

Switch

Screws

Inner

Cam

C

A

B

Outer

Cam

Switch

Switch

Arm

Vertical

Arm

Deploy Limit Switch

Screw

Cam

Stepwell Application

Dropped Floor Application

Deploy Limit Switch

Figure Q

Figure R

Figure S

Floor Level Cam Adjustment:  

The  oor level cam(s) are located on the lower drive 
arm shaft, on the rear side of the frame tube (under 
the cover).  Adjust per application.

• Stepwell Application 

(Figure Q)

1.  Position platform at  oor level.
2.  Loosen the two cam screws.
3.  Adjust the cam for proper switch activation.
4.  Tighten the two cam screws.

• Dropped Floor Application  

(Figure R)

• Up-Stop Adjustment

 (inner cam and switch):

1.  Position platform at original  oor height 

(full up position). 

2.  Loosen screws 

A

B

 and 

C

.

3.  Adjust the inner cam for proper switch 

activation.

4.  Tighten screw 

B

.

• Floor Level Adjustment

 (outer cam and 

switch):

Activated when the platform switches from the 
up/down positions to the stow/deploy positions. 

1.  Position platform at lowered  oor level.
2.  Loosen screws 

A

 and 

C

.

3.  Adjust the outer cam until the  oor level 

switch activates.

4.  Tighten screws 

A

 and 

C

.

                                                                          

Deploy Limit Switch Adjustment 

(Figure S)

This switch adjusts the angle of the platform when 
positioned at  oor level.  The platform should be 
level with the van  oor.  The switch is located on the 
vertical arm where the switch arm pivots.  

1.  Position platform at  oor level.
2.  Loosen the screw that secures the cam to the 

vertical arm.

3.  Level platform using a level (or as needed).
4.  Adjust cam so the deploy limit switch activates.
5.  Tighten screw.
6.  Verify position and check level.

5

Limit Switch Adjustment

6

FMVSS 403/404 Certification Checklist

 

The operations listed below must be func-
tionally veri ed. 

DOT — Private Use Lift

Threshold

Warning Sensor

Audible 

Threshold

Warning

Inboard
Locator

Platform

Switch Arm

Outer Barrier

31312 Rev. A

Vehicle movement is prevented unless the lift 
door is closed, ensuring the lift is stowed.

Lift operation shall be prevented unless the 
vehicle is stopped and vehicle movement is 
prevented.
 
The platform will not fold/stow if occupied.

The inboard locator will not raise if occupied.

The outer barrier will not raise if occupied.

An audible warning will activate if the threshold 
area is occupied when the platform is at least 
one inch below  oor level.

Lowering the platform beyond the inboard loca-
tor locking position is allowed only when the 
inboard locator is locked in position.

Lift platform movement shall be interrupted un-
less the outer barrier is deployed.

Summary of Contents for FMVSS 403

Page 1: ...2 holes inthelowerdoorstopatdimensions shown in Figure B 3 Replace door stop locating on the 2 drilledholes providesadequate clearance 2 3 4 1 7 16 Drill 2 5 16 diameter holes R e a r S w in g D o o r...

Page 2: ...et until Fab Lock has expanded against metal surface Fab Lock Bolt Installation Figure J Figure K Figure M Figure L 2 Insert Fab Lock bolts minimum 2 fully through mounting channel and C pillar Note C...

Page 3: ...lock A 2 circuit lift vehicle interlock interface harness is provided inside the tower cover The Grey Red wire is connected to the battery power stud A butt connector is provided on the Yellow Light B...

Page 4: ...t Figure S This switch adjusts the angle of the platform when positioned at oor level The platform should be level with the van oor The switch is located on the vertical arm where the switch arm pivot...

Page 5: ...n serious bodily injury and or property damage Before lift operation park the vehicle on a level surface away from vehicular traf c Place the vehicle transmission in Park and engage the parking brake...

Page 6: ...y closed Release switch Manual Door s Manually close door s fully TO LOAD PASSENGER 1 Load passenger onto platform fac ing outward and lock wheelchair brakes See Photos Q and R Note Outer barrier must...

Page 7: ...inboard locator to vertical position 2 Place link on inboard locator pin See Figure B 3 Insert hairpin cotter into inboard locator link pin See Figure B TO OPEN DOOR S Manually open door s fully and s...

Page 8: ...s representative or call The Braun Corporation at 1 800 THE LIFT One of our national Product Support representatives will direct you to an authorized service technician who will inspect your lift WARN...