Installation Procedure
1.
Identify installation location.
MEGAbite piping should originate shortly after incoming
water supply shutoff, but just after any outside water lines, such that all water intended for
interior use flows through MEGAbite first.
IMPORTANT: there must not be any filters in-
stalled upstream of the MEGAbite, or insufficient water pressures may affect operational
performance.
This system and installation must comply with state and local laws and regu-
lations.
2.
Connect water piping.
This unit has been supplied with a manually operated bypass device
which enables it to be isolated from the water service lines for maintenance and service, and
also maintain the continuity of the water supply when the MEGAbite is disconnected.
IMPORTANT: Make all sweat-solder connections within 6 inches of the unit before apply-
ing threaded fittings to supplied bypass valve. Overheating may cause damage to valve.
Turn supplied bypass valve to “Bypass” position and make connections to household water
lines. Leave unit in “Bypass” position until startup procedure.
3.
Connect drain line.
Remove barbed drain line fitting from parts bag. Apply thread seal
tape to threads and turn into the female threaded opening on the back side of the control
valve. Connect 5/8” drain line (supplied in parts bag) to barbed end of drain line fitting and
run to a nearby drain.
IMPORTANT: It is highly recommended that a hose clamp be used to secure tubing to
drain fitting to ensure tubing from being removed during elevated pressure situations.
Be sure not to submerse drain line end into drain, as a 1 1/2” minimum air gap must be
maintained to prevent potential backflow hazard. Firmly secure at drain, while maintaining
a minimum 1 1/2” air gap (See detailed drawing on back side of piping diagram).
4.
Connect to electrical power source.
Connect power cord to a separate 120v, 15 amp,
ground fault interrupt (GFI) outlet.
Proceed to start-up procedure.
Note: This system is not intended to be used for treating water that is microbiologically
unsafe or of unknown quality without disinfection before or after the system.