5 Maintenance 

and 

Troubleshooting 

 
There is no preventive maintenance required for the IBU-240.  Moreover, no 
periodic calibration is required. 
 

SYMPTOM POTENTIAL 

CAUSE  CORRECTIVE 

ACTION 

No signal 
outputs 
 
 
 
 
 
 

1.  There is no input 

reference.  

2.  The Reference Select 

switch is selecting 
Reference B and no 
source is connected to 
the Reference B input. 

1.  Connect the reference 

input. 

2.  Select an internal source. 
 
 
 
 

Fault light is 
illuminated 

1.  The input signal level is 

too low. 

2.  There is a failed output 

driver.  

3.  There is an excessive 

load on one or more 
outputs. 

 
 
4.  The output level is 

adjusted too low. 

1.  Increase the input signal 

level. 

2.  Return unit to factory for 

repair. 

3. Disconnect the output 

loads one by one until the 
overloaded output is 
isolated.  Outputs should 
not have loads < 50 ohm. 

4.  Isolate the low output level 

and adjust for a level > 10 
dBm. 

 

 

Summary of Contents for 019000001

Page 1: ...025 REV A User Guide IRIG Distribution Amplifier Model IBU 240 P N 019000001 Revision A February 2006 Brandywine Communications 1153 Warner Avenue Tustin CA 92780 714 755 1050 714 755 0175 http www br...

Page 2: ...MANUAL P N 900000025 REV A 2 Revision History REVISION DATE COMMENT NC 08 31 04 Original release of IBU 240 user guide A 02 20 06 Section 1 1 3 Fault Status added...

Page 3: ...equilateral triangle is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure The dangerous voltage may be of sufficient magnitude to constitute a...

Page 4: ...hes and Indicators 6 1 3 1 Status LED Indicators 6 1 3 2 Environmental 6 1 3 3 Power 6 1 3 4 Physical 6 2 Option Configuration Sheet 7 3 Unpacking and Installation 8 3 1 Unpacking 8 3 2 Installation 9...

Page 5: ...Isolation transformer coupled 1 1 2 Fault Discrete Optional Number of Inputs 2 Level TTL Link selectable for active high or low Forces a changeover when active for on line reference 1 1 3 Fault Status...

Page 6: ...Reference Input B Available Green Reference Input B Online Green Automatic Reference Selection Selected Green Fault Red 1 3 2 Environmental Temperature o Operating 30 to 60 C o Storage 40 to 85 C Humi...

Page 7: ...CTOR FUNCTION LEVEL INSTALLED J1 ALARM INPUT PIN 1 STATUS A PIN 2 STATUS B PIN 3 NO CONN PIN 4 NO CONN PIN 5 NO CONN PIN 6 GROUND PIN 7 GROUND PIN 8 GROUND PIN 9 NO CONN ACTIVE H__Lb ACTIVE H__Lb b J3...

Page 8: ...ry module and verify that the voltage matches the local line s voltage CAUTION THE IBU 240 WILL BE DAMAGED IF THE INCORRECT AC LINE SETTING IS USED WARNING REMOVE THE POWER CORD FROM THE IBU 240 BEFOR...

Page 9: ...o support these cables particularly when the IBU 240 is not mounted on a shelf 3 3 Connections Insert the power cord provided in the shipment into the rear of the power entry module Connect the input...

Page 10: ...t The factory standard IBU 240 configuration is a logic HI signal on the ALARM IN pin indicates that the input is GOOD A built in pull up resistor ensures that if no ALARM IN connection is made the re...

Page 11: ...the time code input references Place the Reference Select switch 3 in the center AUTO position The green Reference A Online LED 4 and the AUTO LED 6 should illuminate This indicates that the IBU 240 o...

Page 12: ...four potential causes for a low signal are listed below 1 The input signal level is too low therefore the output signal monitors have registered the low level as a fault 2 Input B has been manually se...

Page 13: ...connected to the Reference B input 1 Connect the reference input 2 Select an internal source Fault light is illuminated 1 The input signal level is too low 2 There is a failed output driver 3 There i...

Page 14: ...MANUAL P N 900000025 REV A 14 6 Diagrams FIGURE DESCRIPTION 1 IBU 240 Front Panel 2 IBU 240 Rear Panel 3 IBU 240 Mechanical Outline...

Page 15: ......

Page 16: ......

Page 17: ......

Reviews: