background image

DXD8/PTP User Manual (rev 2.15)

Page 15

9.7. DELAY MEASUREMENT MECHANISM 

To synchronize clocks, the delay between the clocks must be known. There are two mechanisms to measure the delay called 
End to End (E2E) and Peer to Peer (P2P). 

•The E2E delay mechanism was the only one included in the original IEEE1588-2002. It measures the delay between 

the master and the slave. 

E2E uses the following messages, as described in 1.6. above: Sync, Follow-up (optional), Delay_Req, and Delay_Resp. 
It can be used with switches or routers that are not 1588 capable.  

•The P2P delay mechanism was introduced in IEEE15880-2008. It measures the delay between directly connected 

ports. Peer-to-peer delay measurement works “locally”, from every node to each of its neighbors. For each pair of 
directly connected ports, each end periodically measures the round-trip network delay by sending a Pdelay_Req 
message and receiving in response a Pdelay_Resp message. This way all ports learn the delay on their link. 

P2P uses messages Pdelay_Req, Pdelay_Resp, and Pdelay_Resp_Follow_Up (optional). 

NOTE: An ordinary clock, which has just one port, can be configured for end-to-end or for peer-to-peer; a boundary clock, 
which can have a single slave port and multiple master ports, can be configured for E2E on some ports and P2P on others. 

While a single domain can have both end-to-end and peer-to-peer delay mechanisms running simultaneously, all clocks on a 
single PTP communication path must use the same method to measure the time delay. 

9.8. TYPES OF CLOCKS 

IEEE 1588 defines three different types of clocks: 

•Ordinary Clock (OC) 
•Boundary Clock (BC) 
•Transparent Clock (TC) 

Ordinary Clocks (OC) are devices with a single port, usually at either end of a network such as A/V equipment, DAW’s or 
speakers. They can be master or slave. 

Boundary (BC) and Transparent (TC) Clocks are network devices such as switches or routers. 

Since the DXD-8 has 1 Ethernet port, it is an ordinary clock (OC). 

9.9. PTP DOMAINS 

A PTP domain is a network (or a portion of a network) within which all of the clocks are in sync. A single network can have 
multiple PTP domains operating separately, e. g., one set of clocks synchronized to one time scale and another set of clocks 
synchronized to an other time scale. 

9.10. PTP PROFILES 

A PTP Profile defines the range and default values of all configurable attributes as well as all required, permitted, or prohibited 
clock types and options for a specific application area. Profiles can be created by recognized standards associations such as 
AES or SMPTE. The DXD supports the AES67 Media profile and the SMPTE ST-2059-2 profile. The DXD also support the 1588 
default profile. 

9.11. EPOCH 

PTP uses the concept of an Epoch clock. This is an absolute time value when the clock was set to zero, and the number of 
1GHz clock pulses that have occurred since provides the current time, converted with software into year, month, day, hours, 
minutes and seconds. The Epoch (or zero time) for PTP was set at midnight on the 1st January 1970 (TAI). 

Summary of Contents for DXD-8

Page 1: ...l Clock Operations manual Version 2 15 October 2021 All materials herein Brainstorm Electronics Inc Brainstorm Electronics reserves the right to change or modify the contents of this manual at any tim...

Page 2: ...9 6 Time Menus 9 6 1 TIME STANDARDS MENU 7 1 9 6 2 TIME DATE DISPLAY MENU 7 3 9 7 Time Code Menus 9 7 1 SMPTE 2059 SETUP MENU 8 1 9 7 2 LTC GENERATOR 1 2 MENUs 8 2 8 3 10 8 Display 10 8 1 Main Rotati...

Page 3: ...tion 20 13 1 SELECTING PTP V1 20 13 2 DIFFERENCES IN SETTINGS FOR PTP MENU 5 2 GRANDMASTER 20 13 3 DIFFERENCES IN SETTINGS FOR PTP MENUS PORT TIMING 20 14 AVB IEEE 802 1as gPTP Firmware Option 21 15 G...

Page 4: ...PTP be sure to update your DXD 8 with the latest fi rmware available on the Brainstorm website When you purchased your DXD PTP you received a unique authorization key a series of 4 numbers separated...

Page 5: ...lable this fields enables GPS to be set as the reference when the DXD 8 is the Grandmaster Enabling this field will announce the DXD 8 as GPS referenced giving it a higher priority at being selected b...

Page 6: ...al networks would set all the parameters to the default values and allow for a quick set up Selecting Load pro fi le defaults will cause all the timing values to reset to the pro fi le default values...

Page 7: ...e year month day hour and seconds even nanoseconds to achieve frequency and phase synchronization At the heart of the DXD 8 is the Main Time of Day Clock TOD Reference Frame Generator This is where S...

Page 8: ...ck to PTP When that is achieved the DXD 8 will release the PTP Lock and revert to the BNC source selected in the reference menu Reasons to PTP time jam DXD 8 s include Locking to a common video refere...

Page 9: ...Ethernet port from the external PTP Grandmaster 6 2 TIME DATE DISPLAY MENU 7 3 With the PTP option Ext PTP Grandmaster is added to the list available in menu 7 3 where 2 different DXD times dates can...

Page 10: ...displayed in the reference line But if the DXD 8 is selected one of the other 3 options above will be displayed Internal Internal OCXO or GPS Receiver Lock Status The bottom line of the display has th...

Page 11: ...on the main display while in the STATUS mode To activate the STATUS mode press the STATUS key The Status LED illuminates to con fi rm your selection This fi rmware update includes the following new S...

Page 12: ...Response Peer Delay Request Peer Delay Response Those are running counters and can be cleared by pressing the ENTER key Monitoring the messages exchanged is useful when troubleshooting Announce and S...

Page 13: ...e ability to clock to a non Dante PTP v2 clock AVB Audio Video Bridging is a set of IEEE standards that facilitate the transport of high performance audio and video on a LAN One of those standards IEE...

Page 14: ...tter suited clock is found it will become the Grandmaster 9 6 SYNCHRONIZATION There are several different PTP messages used during synchronization sequenced as follows 1 The grandmaster sends a Sync m...

Page 15: ...locks on a single PTP communication path must use the same method to measure the time delay 9 8 TYPES OF CLOCKS IEEE 1588 de fi nes three different types of clocks Ordinary Clock OC Boundary Clock BC...

Page 16: ...port can change The BMCA determines what unit becomes the Grandmaster If the current Grandmaster disappears or looses GPS another Grandmaster is selected For more on the Grandmaster selection go to 9...

Page 17: ...difference detected between the external PTP GM and the DXD System Time is above the PTP Jump Threshold value the DXD will jump to the new time and relock through the normal lock procedure This will...

Page 18: ...all equipment could be kept perfectly synchronized But for added fl exibility the DXD s can also be set up to lock to any legacy sync or to PTP as illustrated below These choices are available in the...

Page 19: ...slaves to an external Grandmaster in the second illustration the DXD 8 s are all Grandmaster for their networks and each is locked to GNSS This second solution is particularly useful when distances b...

Page 20: ...bscure PTPv1 keeps track of whether or not a device is a Boundary Clock and PTPv2 PRIORITY 2 is mapped to that setting as follows PRIORITY 2 127 or less Boundary Clock TRUE PRIORITY 2 128 or more Boun...

Page 21: ...when in PTPv1 mode You may continue to use the same setting as you would for PTPv2 14 AVB IEEE 802 1as gPTP Firmware Option The DXD 8 supports 2 versions of the IEEE 802 1AS standard the original vers...

Page 22: ...NTS PTP Domain Devices that need to be synchronized together via PTP must be part of the same domain Be sure the PTP domain is set properly on your DXD as messages with any other domain number will be...

Page 23: ...pports IGMPv2 On larger networks a router is required to manage multicast group membership Switches that support IGMP Snooping are also recommended 16 Troubleshooting Error Warning Messages 16 1 PTP N...

Page 24: ...Menu 5 1 If PTP was selected TIME JAM BNC INPUT will automatically show in menu 5 1 in blue blue status information The words Time Jam will also appear on the REFERENCE line at the bottom of the main...

Page 25: ...TION No Action DELAY MECHANISM E2E End to End ANNOUNCE INTERVAL 2 sec log 1 ANNOUNCE RECEIPT TIMEOUT 3 announce intervals SYNC INTERVAL 1 2 sec log 1 MINIMUM DELAY REQUEST INTERVAL 2 sync intervals PO...

Reviews: