Analog Terminal Board
Reference
Jumpers Settings, W1-W4.
_______________________
There are four jumpers on the ATB. The functions are
summarised in Figure 1-2.
Jumpers W1 and W2 are used only in with the thermocouple
cold junction compensation circuitry. W1 connects the CH0 input
to the cold junction circuit whilst W2 connects the CH0 return
line to ANALOG ground.
Jumper W3 connects the system ground, SYS GND, to the
ANALOG ground. Single Ended inputs normally have a return
path via analog ground and this jumper connects the analog
ground to SYS GND.
Jumper W4 connects the AMPLOW to the ANALOG ground.
Pseudo differential inputs are referenced to AMPLOW. This
jumper can be used in conjunction to W3 to connect AMP LOW
to the system ground SYS GND.
Figure 1-2. Jumper Table.
_______________________
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³
³
³
³
Jumper Settings
³
Input Types
³
³
³
³
ÃÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³ý
W1
³ý
W2
³ý
W3
³ý
W4
³
³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³ýý
In
ý³ýý
In
ý³ýý
In
ý³ýý
In
ý³
Active Thermocouple CJC
³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³ýý
Out
ý³ýý
Out
ý³ýý
In
ý³ýý
In
ý³
4-20mA Current Inputs
³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³ýý
Out
ý³ýý
Out
ý³ýý
In
ý³ýý
In
ý³
Voltage Inputs
³
³ýý
ýý³
ýý³ý
ý³
ý³ý
ýýý
³
ÀÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
Differential Analog Inputs, 8DI.
____________________________
Always use the 8 Differential input scheme, in preference
to any other scheme, where ever possible and also when:-
a)
using low level input signals, (less than 1 Volt full scale).
b)
in noisy environments.
c)
there is no common ground shared by the analog signal
sources.
The 10k Ohm Differential return path resistors should be fitted,
Page 3