background image

15756_r02 

3/6 

 

 

 

44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวีวัฒนา กทม. 10170. 
website: 

https://www.add-furnace.com/

 โทร: 02-888-3472 

Line ID: @add11  e-mail: [email protected] 

OVERALL DIMENSIONS 

The  EUROBOX  series  burner  control  units  can  be  provided  with  a 
different casing according to the characteristics and fixing systems 
required. 
Casings are available with or without reset push-button and can be 
equipped  with  lateral  fixing  brackets  or  not.  Please    note  that  the 
units  equipped  with  lateral  fixing  brackets  can  be  fitted  to  sockets 
type  "P"  or  "R"  only,  as  these  are  provided  with  suitable  fixing 
hooks. The numeric suffix in the part reference indicates the type of 
casing: 

with reset push-button; 

with fixing brackets 

with reset push-button; 

without fixing brackets 

without reset push-button; 

with fixing brackets 

without reset push-button; 

without fixing brackets The 

possibility of using casings without reset push-button is restricted to 
the control units prearranged for remote reset. Fig.1 shows the 
overall dimensions of the units. 

CM381. Socket type P differs from type R on positions 8       and 10 
for the availability of through holes  to suit female  fast-on terminals 
of standard type. 
As regards the connection of the control  units,  strain  relieves and 
a  sufficient  number  of  earth  and  neutral    terminals  should  be 
available in the appliance or in external connection boxes. 

 

 

 

 

 

 

Fig.1 

ACCESSORIES 

The control units are usually supplied with inbuilt reset push-button; 
versions with remote reset supplied with a suitable light reset push-
button are also available  (see  Fig.2). 
The  casings  of  the  control  units  are  prearranged  for  the  use  of 
strain  relieves/cable  glands  to  be  mounted  on  their  sides;  also 
these accessories can be supplied upon request (see Fig.3). 

RESET PUSH-BUTTON 

DRILLING  PLANE 

Socket R   Fig. 4 

 
 
 
 
 
 
 
 
 

 
 

CODE 81020980 

 

 

Reset 1      

Lockout signal 2 

 

 

3 Neutral 

 
 
 

 

 

 

Fig.2 

 
 
 
 

Fig.3 

 
 
 
 
 
 
 
 

 

INSTALLATION DIRECTIONS 

 
 
 
 
 
 
 

Socket NG   Fig. 5 

CONNECTION 

For  this  series  of  burner  control  units,    various    interconnection 
solutions  are  possible.  In  fact,    different    types  of  connecting 
sockets  can  be  used  (see  Fig.4  and          Fig.5):  types  NG  (code 
18210094)  and  MG    (code    18210113)  are  equipped  with  screw 
terminal    board,    whereas  types  P  (code  18210096)  and  R  are 
provided with  a number of fast-on holders. 
Socket  type  MG  differs  from  type  NG  for  the  availability  of        an  
auxiliary  terminal  requested  for  the  control  unit   type 

  A  regulation  shutdown  should  occur  every  24  hours  to  enable 

the unit to check its own efficiency (systems for non-permanent 
operation).

  Ignition  systems  are  safety  devices;  the  manufacturer's 

responsibility  and  guarantee  are  invalidated  in  case  of 
Customer's tampering with the product.

  Connect and disconnect the control unit only after switching off 

the power supply.

  The unit can be mounted in any position.

  Avoid exposure to dripping water.

Reviews: