Braemar Seeley WF30 Owner'S Manual Download Page 2

 

SEELEY INTERNATIONAL –

 

OWNER’S MANUAL

2

 

 

 

 

Introduction

For satisfactory performance of your 

Braemar gas wall furnace, please read 

these instructions carefully.  The 

operation of the heater is controlled by 

the gas control knob and fan switch 

located behind the access door on the 

front cover.

Fan Operation

The fan will start automatically in both 

AUTO and BOOST positions when the 

unit is warm enough after the burner is 

turned on, and stop automatically when 

the unit has cooled sufficiently after the 

burner turns off.  With AUTO selected 

the unit will automatically select 

between "low" and "normal"  (and 

“boost” on 40MJ models) fan speeds 

based on the heated air temperature - 

no further user adjustment is necessary. 

When BOOST is selected the fan will 

run only on its boost speed. It is 

recommended that the manual fan 

switch be set to AUTO for normal 

operation, or BOOST for rapid heat-up.

Gas Control

To light the heater:

- Turn the gas control knob anti-

   clockwise from the “0” position to the

         position.

- Depress knob fully and hold down.

- Press the igniter button located next to

   the gas control knob 3-4 times.

- Observe the pilot meter to indicate

   operation of the pilot.

- Wait 20 seconds then release the gas

   control knob and check the pilot meter

   stays on.

- Repeat the process if required.

OPERATING INSTRUCTIONS

1

WF30/40

Gas control knob

Igniter button

Pilot meter

Fan

Auto / Boost

switch

I

IMPORTANT MAINTENANCE (AND WARRANTY) INFORMATION

As with any product that has moving parts or is subject to wear and tear, it is 

VERY 

IMPORTANT

 that you maintain your wall furnace and have it regularly serviced. It is a 

condition of warranty cover for your wall furnace that you comply with all of the maintenance 
and service requirements set out in this Owner’s Manual. Compliance with these 
requirements will prolong the life of your wall furnace. Further, it is also a condition of 
warranty cover that each item in the Maintenance Schedule in this Owner’s Manual is 
performed with the frequency indicated, by a qualified, licensed technician, and that the 
Maintenance Schedule is properly filled out (ie names, signature, date, and action taken) 
when the item is completed. 

ANY FAILURE TO CARRY OUT THE REQUIRED 

MAINTENANCE AND SERVICING REQUIREMENTS, AND ANY FAILURE TO PROPERLY 

FILL OUT THE MAINTENANCE SCHEDULE, WILL VOID YOUR WARRANTY.

Warning

DO NOT:

 Place articles on or against this appliance.

DO NOT: 

Use or store flammable materials near this appliance

DO NOT:

 Spray aerosols in the vicinity of this appliance while it is in operation.

DO NOT:

 Modify this appliance.

IMPORTANT

If for any reason your heater experiences,        

a POWER FAILURE

the “Pilot Flame”  is 

TURNED OFF, or GOES OUT, a period of up to 

5 minutes is required for the heater to reset.

If the heater has not reset, the

“Gas control knob” will NOT turn easily.

PLEASE DO NOT FORCE

Damage to the mechanism may occur.

Care Instructions

External surfaces should be cleaned with warm water and detergent with the heater turned off. 

Do not use abrasive cleaners as scratching of the surface will occur.

 

Heat Setting

- Turn gas control knob anti-clockwise to

   desired heat setting between “1” and

   “7”.

- The heater will automatically adjust the

   gas flow to maintain the room

   temperature corresponding to the

   selected heat setting.

To Increase Heat Setting

- Turn gas control knob anti-clockwise

   towards “7”.

To Decrease Heat Setting

- Turn gas control knob clockwise

   towards “1”.

To Turn Off Main Burner 

(Pilot-Stand by)

- Turn gas control knob clockwise

   to a position between the word PILOT

  & the symbol        . 

                        (see 

“Pilot zone”

 Figure 1 below)

   It is recommended that the pilot be

   left in operation during the heating

   season.

To Turn Off Completely 

(end of heating 

season)

- Turn gas control knob clockwise

   to the “0” position.

Figure 1:

To Turn Off Main Burner 

(Pilot-Stand by)

Heater will now only re-start when control knob

is turned to a heat setting of 1 to 7.

“Pilot zone”