CHECK BEFORE CALLING FOR SERVICE cont.

c. The Braemar SCC has special safety features built in to protect

your Add-On Cooling system. It will switch off the Add-On Cooling
output signal when the supply air temperature drops below a pre-
set minimum value and will restart after the supply air temperature
rises by a pre-set value and the delay timer has elapsed.

d. Call the installer to check you have the required number of outlets

open

e. Once the above have been checked and repaired as required, call

1300 657 506

It is important that you recognise whether the fault is with the Ducted Gas Heater
or if the fault is with the Add-On Cooling Unit. For prompt, efficient service, please
follow the above before calling the appropriate number below.

When calling the Warranty Service number, please ensure you have your model
and serial number available, along with date of purchase, and if possible a
description of the problem.

Please NOTE

For Refrigerated Cooling Issues

1300 657 506

For Ducted Heater Issues

1300 650 644

CHECK BEFORE CALLING FOR SERVICE

Before calling Service, please check the following:

Braemar SCC

1300 650 644

1300 650 644

1300 657 506

1. If a new installation, please contact the installer to ensure the
installation has been completed and commissioned.

2. You MUST have a control as shown

, if not,

please

refer back to your installer.

3. Does the display show any information?

a. If yes, go to Step 4.
b. If No, check power supply to Heater.

i. Repair power supply and set time and day.
ii. Follow procedure in your Braemar Ducted Gas Heater

Owner's Manual on how to set up and operate your system.

iii. After completing the above checks and rectifying any fault as required, if

your appliance continues not to operate, please call

4. Does the display show a

Snow Flake

symbol?

a. If Yes,

i. Is there air coming out of the outlets in your home?
ii. If No,

1. Ensure SCC is set to COOL and the set point is below the room

temperature.

2. Check and clean return air filter.
3. Check and open outlets and/or zones.
4. Check duct for disconnection or damage.
5. After the above have been checked and repaired as required, please

call

b. If Yes, continue below:

i. Check Circuit Breaker and/or Isolator to Add-On Cooling Unit. If
electricity is available, the Unit may be timing out on the inbuilt safety

timer. Wait 5 minutes and re-check.

ii. If fan is blowing on Outdoor unit, check large pipe's temperature, this

pipe should be cold to touch.
If not cold, please have the installer check for refrigerant leaks before
calling Braemar Service on

iii. Does the Add-On Cooling run for short periods of time?
1. If No, refer 4.a.ii above
2. If Yes,

a. Check to ensure enough outlets are open.
b. Check and clean return air filter.

SACC Series Add-On Cooling Unit

Summary of Contents for SACC Series

Page 1: ...OWNER S MANUAL SACC Series Add On Cooling Unit English SACC ...

Page 2: ...t you maintain your air conditioner and have it regularly serviced Accordingly it is a condition of warranty cover for your air conditioner that you comply with all of the maintenance and service requirements set out in this Manual Compliance with these requirements will prolong the life of your air conditioner Further it is also a condition of warranty cover that the Maintenance Schedule in the M...

Page 3: ...SEELEY INTERNATIONAL OWNER S MANUAL 1 MAIN COMPONENTS INDOOR COIL OUTDOOR UNIT Indoor Unit Indoor and Outdoor unit operating temperature range 18 C 32 C Outdoor Unit 20 C 48 C ...

Page 4: ...and the Maintenance Schedule This will also prolong the life of your air conditioner The home owner user should regularly check the Air Inlet side of the Outdoor unit see the diagram on page 1 to ensure grass leaf and other matter are not drawn into or onto the Inlet side of the Outdoor unit Restriction to the air flow across the coil will reduce the system s capacity and result in high operation ...

Page 5: ...irements may result in the Add On Cooling Unit not performing adequately or at all and void the warranty CONNECTION TO OTHER DUCTED GAS HEATER BRANDS WARNING This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the applian...

Page 6: ... the Maintenance Schedule below Drains can become blocked by all types of insects and rats have been known to chew through the drain to get to the water in the pipe The Outdoor unit has either one or two fans it draws air through the appliance to expel the heat generated during the cooling cycle We recommend REFER PAGE 1 checking that plants haven t grown into or around the air intake or outlet al...

Page 7: ...debris Check refrigerant charge Check refrigeration connections for soundness Check outdoor fans Check electrical connections Check ductwork including but not limited to duct fittings zone dampers grilles Check overall installation Report to the home owner user all tasks that require attention Please NOTE the Maintenance Schedule covers Year 1 to Year 5 To preserve your investment for many years a...

Page 8: ...e symbol a If Yes i Is there air coming out of the outlets in your home ii If No 1 Ensure SCC is set to COOL and the set point is below the room temperature 2 Check and clean return air filter 3 Check and open outlets and or zones 4 Check duct for disconnection or damage 5 After the above have been checked and repaired as required please call b If Yes continue below i Check Circuit Breaker and or ...

Page 9: ...ck you have the required number of outlets open e Once the above have been checked and repaired as required call 1300 657 506 It is important that you recognise whether the fault is with the Ducted Gas Heater or if the fault is with the Add On Cooling Unit For prompt efficient service please follow the above before calling the appropriate number below When calling the Warranty Service number pleas...

Page 10: ...traction of the plastic parts in the Unit when the temperature is changing This is a normal condition when the air conditioner has not been used for a long time or during first use of the Unit This is caused by the Indoor unit giving off smells permeated from building material from furniture smoke for example if someone is cooking food or from the duct work When indoor air temperature reaches the ...

Page 11: ...ge in this event a clicking sound may occur 1 1 Wait for power to resume 1 2 Replace the fuse or reset the breaker 1 3 Check thermostat setting 2 1 Wait a while so the Unit has enough time to cool the room 3 1 This is normal NOTE Seeley International strives for continuous product improvements therefore specifications are subject to change without notice Unit colour may vary slightly from that dep...

Page 12: ...Ducted Gas Heating 1300 650 644 seeleyinternational com It is the policy of Seeley International to introduce continuous product improvements Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specifications of the model selected ...

Reviews: