PROGRAMMING

USER SETTINGS

4

4.1

Default Thermostat Settings

NOTE:

 

 

To erase all user program settings, gently press 

RESET

 button using a 

paperclip or a small pencil tip. This will return all thermostat settings to their 

default values.

Function 

Status After Reset

Operation Mode 

Normal Operating Mode

Room Temperature 

70˚ F (21.0˚ C), to be renewed within 

 

5 seconds

Setpoint Temperature 

According to system switch:

 

62˚ F (17.0˚ C) for Heat or Off 

 

85˚ F (29.0˚ C) for Cool

Temperature Scale 

˚F or ˚C dependent on switch setting

Temperature Differential 

0.5˚ F (0.25˚ C)

Short Cycle Protection Timer  Reset

Output Relays 

Off

NOTE:

 

 

Once you have finished setting the temperature differential you can wait 5 

seconds and the thermostat will automatically return to the normal operating mode. 

Otherwise, you can press both the     and     buttons at the same time again to return you 

to normal operating mode.

4.

  Place the system switch in the 

COOL

 position.

5.

  Press the     button on the keypad until the setpoint temperature is a minimum of 3 degrees  

 

  lower than the current room temperature.

6.

  The cooling system should start within several seconds. Place the system switch in the 

OFF

  

 

  position. The cooling system should stop within a few seconds.

7.

  Place the fan switch in the 

ON

 position. The system blower should start.

8.

  Place the fan switch in the 

AUTO

 position. The system blower should stop.

4.2

Setting Temperature Differential

NOTE:

 

 

The temperature differential settings are the same for both the heating and 

cooling systems.

The default settings for the temperature differential is compatible with most systems and 

applications. The temperature differential is normally set at time of installation and usually does 

not require any modification under normal operating conditions. If you feel that your system is 

turning on too often, simply follow the instructions below.

The default setting is 0.5˚ F (0.25˚ C). The room temperature must change 0.5˚ F (0.25˚ C) from 

the setpoint temperature before the thermostat will initiate the system in heating or cooling.

2.

 Press the     or     buttons to set the temperature differential to your desired setting of .5˚, 1˚, 

  

 

or 2˚ F (.25˚––displayed as .2˚, .5˚, or 1˚ C).

1.

 In normal operating mode, press and hold    

  both the     and     buttons at the same time   

  for 4 seconds. LCD display will show "

SET   

  D1 x

˚", where "

x

" equals the ˚F / ˚C  

 

  differential setting. This is the current  

 

  temperature differential setting.

TESTING YOUR 

NEW THERMOSTAT

3

cont.

5.1

Review Set Temperature

5

NOTE:

  

The installer can reset the thermostat and bypass the compressor protection 

feature by pressing the 

RESET

 button. This will erase all user program settings and 

should only be used during installation for testing purposes or to reset a thermostat to 

regain normal operation. This will return all thermostat settings to their default values.

5.2

Changing Set Temperature

5.3

Compressor Protection Feature

5.5

Resetting Thermostat

5.4

Non-Volatile Memory

In the event of a power failure, the non-volatile memory feature of this unit allows all settings 

to be recovered, eliminating the need to reset temperature and differential settings. When AC 

power is restored after an outage, all settings are retrieved from memory and reinstated.

The Reset feature allows the user to completely reset the thermostat to register new manual 

switch settings and return to factory set software settings.

1.

 To erase all entered settings, gently press 

RESET

 button using a paper clip or a small 

pencil tip.

2.

 This will return all thermostat settings to their default values and register all new manual 

switch settings for proper operation.

ADDITIONAL 

OPERATION FEATURES

5

1.

Press and hold     or     button. The current setpoint temperature  

       

      

  will be displayed in the place of the current room temperature,  

 

  and the indicator 

SET

 will be displayed.

2.

 The display will return to normal operating mode when the     or      

 

  buttons are released. The 

SET

 indicator will turn off, indicating  

 

  that the current temperature shown in the display is the room temperature. Continuing  

  to hold the     or     button for 3 seconds or longer will allow the user to change  

  the current setpoint temperature (See 

Changing Set Temperature

).

1.

Press and hold     or     button for 3 seconds. The entire display  

  will flash once and the 

SET

 indicator will be flashing. Release  

  the     or     button and press the     or     button again as desired  

  to adjust the set temperature.

2.

The display will return to normal operating mode after 5 seconds.

3.

The 

SET

 indicator will turn off in the display, indicating that the  

  current temperature shown in the display is the room temperature.

This thermostat includes an automatic compressor protection feature  

 

 

to avoid potential damage to the cooling system from short cycling.  

 

 

This thermostat automatically provides a 5-minute delay after turning    

 

off the cooling system output to protect the compressor. This protection is also present in the 

heat mode of operation on single stage heat pump systems to protect the compressor.

Summary of Contents for Builder 1010

Page 1: ... all building codes and ordinances as required by local and national code authorities having jurisdiction Do not short or jumper across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation This could damage the thermostat and void the warranty Do not select COOL mode of operation if the outside temperature is below 50 F 10 C This could po...

Page 2: ...programmed This will erase all user settings and return them to their default values WARNING Read BEFORE Testing Do not short or jumper across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation This could damage the thermostat and void the warranty Do not select COOL mode of operation if the outside temperature is below 50 F 10 C This c...

Page 3: ...ferential setting TESTING YOUR NEW THERMOSTAT 3 cont 5 1 Review Set Temperature 5 NOTE The installer can reset the thermostat and bypass the compressor protection feature by pressing the RESET button This will erase all user program settings and should only be used during installation for testing purposes or to reset a thermostat to regain normal operation This will return all thermostat settings ...

Page 4: ...tem is turned on and running Check thermostat wiring to make sure that the fan control wiring is connected to the correct terminals on the wiring terminal block See Installation and Wiring Diagrams sections of this manual The room is too warm or too cold See Review Set Temperature section of this manual to verify the current setpoint and make any modifications that are necessary LO is shown in the...

Page 5: ...iability does not apply to batteries nor does it include damage to merchandise or the thermostat resulting from accident alteration neglect misuse improper installation or any other failure to follow Braeburn installation and operating instructions Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our wa...

Reviews: