MODEL 1000, 1000NC:  Single Stage Heat Pump System

Compressor

Control

cont.

Wiring Diagrams

9

Transformer Common

(See NOTE 1)

cont.

Wiring Diagrams

9

R

O

Reversing Valve

(Active in Cooling

- See NOTE 3)

B

Y1

G

W2

Transformer Common

(See NOTE 1)

1st Stage

Compressor

Contact

Emergency

Heat Control

2nd Stage

Heat Control

Fan Control

24 VAC

See NOTE 2

MODEL 1200, 1200NC:  Multi-Stage Heat Pump Systems

NOTES:

  

1.

 Transformer common not required for battery-only operation of 

thermostat. 

2.

 Jumper is required to use Auxiliary Heat for both Second Stage and 

Emergency Heat on units without separate Emergency Heat and Auxiliary Heat terminals. 

3.

 For units requiring reversing valve to be energized during heating, connect reversing 

valve to B terminal. For units requiring reversing valve to be energized during cooling, 

connect reversing valve to O terminal.

Reversing Valve

(Active in Heating

- See NOTE 3)

C

E/W1

(See 

NOTE)

Transformer 

Common

 

R

Y1 E/W1

W2

G

O

B

C

1st Stage

Compressor

Control

1st Stage 

Heat Control

Fan

Control

2nd Stage

Heat Control

24 VAC

Neutral

120 VAC

Hot

MODEL 1200, 1200NC:  Conventional Systems (Single Transformer)

NOTE:

  

Transformer common not required for battery-only operation of thermostat. 

10

11

B

Reversing 

Valve (Active in 

Cooling - See 

NOTE 2)

O

W

C

24 VAC

Reversing 

Valve (Active in 

Heating - See 

NOTE 2)

Y

G

Rc Rh

Factory Installed

Jumper

Fan

Control

Neutral

120 VAC

Hot

Neutral

120 VAC

Hot

NOTES:

  

1.

 Transformer common not required for battery-only operation of 

thermostat. 

2.

 For units requiring reversing valve to be energized during heating, 

connect reversing valve to B terminal. For units requiring reversing valve to be 

energized during cooling, connect reversing valve to O terminal.

Summary of Contents for Builder 1000

Page 1: ...t pumps can also be used on 250mv to 750mv millivolt heating only systems Old Terminal from Existing Thermostat New Terminal for New Thermostat 1000 1000NC New Terminal for New Thermostat 1200 1200NC Terminal Description V or Rc Rc Cooling Transformer M 4 Rh or R Rh Heating Transformer R V VR or VR R R 24 VAC B B B Reversing Valve Heating O O O Reversing Valve Cooling Y Y1 or M Y Y1 Cooling or Com...

Page 2: ...e warranty Do not select COOL mode if the outside temperature is below 50 F 10 C This could damage the controlled cooling system and cause personal injury This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling This thermostat automatically provides a 5 minute delay after turning off the cooling or heating system output...

Page 3: ...is is the current second stage differential setting 4 Press the or buttons to set the second stage differential to your desired setting of 2 3 4 5 or 6 F 1 1 5 2 2 5 or 3 C NOTE MODEL 1200 1200NC Once you have finished setting the second stage differential you can wait 5 seconds and the thermostat will return to the normal operating mode Or you can press both the and buttons at the same time to re...

Page 4: ...serted all settings are retrieved from memory and reinstated 7 Troubleshooting 8 Additional Operation Features cont 6 COOL Battery Replacement 7 Status Indicators HEAT This will turn on whenever the system switch is in the HEAT mode HEAT will flash when the heating system is running COOL This will turn on whenever the system switch is in the cool mode COOL will flash when the cooling systems is ru...

Page 5: ... to 37 C display range Turn on the heating system to raise the temperature as needed for comfort within the room This condition could occur from the system being turned off during a cold weather period or upon installation when the thermostat has been stored for a long period of time in a cold vehicle or location prior to being installed The thermostat should be allowed to warm up prior to install...

Page 6: ... requiring reversing valve to be energized during cooling connect reversing valve to O terminal Reversing Valve Active in Heating See NOTE 3 C E W1 See NOTE Transformer Common R Y1 E W1 W2 G O B C 1st Stage Compressor Control 1st Stage Heat Control Fan Control 2nd Stage Heat Control 24 VAC Neutral 120 VAC Hot MODEL 1200 1200NC Conventional Systems Single Transformer NOTE Transformer common not req...

Page 7: ...ostat against any defects that are due to faulty material or workmanship This warranty and our liability does not apply to batteries nor does it include damage to merchandise or the thermostat resulting from accident alteration neglect misuse improper installation or any other failure to follow Braeburn installation and operating instructions This limited warranty applies for the duration of the w...

Reviews: